CAT1640LI-25-G ON Semiconductor, CAT1640LI-25-G Datasheet - Page 2

no-image

CAT1640LI-25-G

Manufacturer Part Number
CAT1640LI-25-G
Description
IC SUPERVSR CPU 64K EEPROM 8PDIP
Manufacturer
ON Semiconductor
Type
Simple Reset/Power-On Resetr
Datasheet

Specifications of CAT1640LI-25-G

Number Of Voltages Monitored
1
Output
Open Drain or Open Collector
Reset
Active Low
Reset Timeout
130 ms Minimum
Voltage - Threshold
2.55V
Operating Temperature
-40°C ~ 85°C
Mounting Type
Through Hole
Package / Case
8-DIP (0.300", 7.62mm)
Monitored Voltage
3 V, 3.3 V, 5 V
Output Type
Active Low, Open Drain
Manual Reset
Resettable
Watchdog
No Watchdog
Battery Backup Switching
No Backup
Supply Voltage (max)
5.5 V
Supply Voltage (min)
3 V
Supply Current (typ)
3000 uA
Maximum Power Dissipation
1000 mW
Maximum Operating Temperature
+ 85 C
Mounting Style
Through Hole
Minimum Operating Temperature
- 40 C
Power Fail Detection
No
Undervoltage Threshold
2.55 V
Overvoltage Threshold
2.7 V
Power-up Reset Delay (typ)
270 ms
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CAT1640LI-25-G
Manufacturer:
TI
Quantity:
2 000
PIN DESCRIPTION
RESET/RESET
These are open-drain pins and RESET can also be used
as a manual reset trigger input. By forcing a reset condition
on the pin the device will initiate and maintain a reset
condition. The RESET pin must be connected through a
pull-down resistor and the RESET pin must be connected
through a pull-up resistor.
SDA:
The bidirectional serial data/address pin is used to trans-
fer all data into and out of the device. The SDA pin is an
open drain output and can be wire-ORed with other open
drain or open collector outputs.
PIN FUNCTIONS
CAT1640, CAT1641
Doc. No. MD-3012, Rev. D
BLOCK DIAGRAM — CAT1640, CAT1641
Pin Name
EXTERNAL LOAD
V CC
V SS
SDA
RESET
RESET
SDA
SCL
V
V
CC
SS
SERIAL DATA ADDRESS
RESET
RESET
RESET
RESET:
START/STOP
CONTROL
LOGIC
Function
Serial Data/Address
Active Low Reset Input/Output (CAT1640)
Ground
Clock Input
Active High Reset Output (CAT1641)
Power Supply
WORD ADDRESS
LOGIC
RESET Controller
RESET OUTPUTS
BUFFERS
Vcc Monitor
D OUT
Precision
ACK
RESET (CAT1640)
RESET (CAT1641)
XDEC
SHIFT REGISTERS
STATE COUNTERS
SLAVE
ADDRESS
COMPARATORS
DATA IN STORAGE
TIMING CONTROL
HIGH VOLTAGE/
SENSE AMPS
DECODERS
COLUMN
EEPROM
64kbit
2
SCL
A0
A1
A2
SCL:
Serial clock input.
A0, A1, A2:
When hardwired, up to eight CAT1640/41 devices may
be addressed on a single bus system (refer to Device
Addressing). When the pins are left unconnected, the
default values are zeros.
SERIAL CLOCK
OPERATING TEMPERATURE RANGE
DEVICE ADDRESS INPUTS
Threshold Voltage Options
Part Dash
Industrial
Number
-45
-42
-30
-28
-25
Characteristics subject to change without notice.
Threshold
Minimum
© 2009 SCILLC. All rights reserved.
4.50
4.25
3.00
2.85
2.55
-40˚C to 85˚C
Threshold
Maximum
4.75
4.50
3.15
3.00
2.70

Related parts for CAT1640LI-25-G