AT91SAM7S64C-AU Atmel, AT91SAM7S64C-AU Datasheet - Page 500

IC ARM7 MCU 32BIT 64K 64LQFP

AT91SAM7S64C-AU

Manufacturer Part Number
AT91SAM7S64C-AU
Description
IC ARM7 MCU 32BIT 64K 64LQFP
Manufacturer
Atmel
Series
AT91SAMr
Datasheet

Specifications of AT91SAM7S64C-AU

Package / Case
64-LQFP
Voltage - Supply (vcc/vdd)
1.65 V ~ 1.95 V
Operating Temperature
-40°C ~ 85°C
Speed
55MHz
Number Of I /o
32
Core Processor
ARM7
Program Memory Type
FLASH
Ram Size
16K x 8
Program Memory Size
64KB (64K x 8)
Data Converters
A/D 8x10b
Oscillator Type
Internal
Peripherals
Brown-out Detect/Reset, DMA, POR, PWM, WDT
Connectivity
I²C, SPI, SSC, UART/USART, USB
Core Size
16/32-Bit
Core
ARM7TDMI
Package
64LQFP
Device Core
ARM7TDMI
Family Name
AT91
Maximum Speed
55 MHz
Operating Supply Voltage
1.8|3.3 V
Data Bus Width
32 Bit
Number Of Programmable I/os
32
Interface Type
SPI/TWI/USART/USB
On-chip Adc
8-chx10-bit
Number Of Timers
3
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-
Lead Free Status / Rohs Status
 Details
Other names
AT91SAM7S64B-AU::AT91SAM7S64B-AU

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT91SAM7S64C-AU
Manufacturer:
ATMEL
Quantity:
4 300
Part Number:
AT91SAM7S64C-AU
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT91SAM7S64C-AU
Manufacturer:
ATMEL
Quantity:
1 005
Part Number:
AT91SAM7S64C-AU
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
AT91SAM7S64C-AU-999
Manufacturer:
Atmel
Quantity:
10 000
35.4
35.4.1
35.4.2
500
Typical Connection
AT91SAM7S Series Preliminary
USB Device Transceiver
VBUS Monitoring
Figure 35-2. Board Schematic to Interface USB Device Peripheral
The USB device transceiver is embedded in the product. A few discrete components are
required as follows:
Pullup enable/disable is done through a MOSFET controlled by a PIO. The pullup is enabled
when the PIO drives a 0. Thus PIO default state to 1 corresponds to a pullup disable. Once the
pullup is enabled, the host will force a device reset 100 ms later. Bus powered devices must
connect the pullup within 100 ms.
VBUS monitoring is required to detect host connection. VBUS monitoring is done using a stan-
dard PIO with internal pullup disabled. When the host is switched off, it should be considered as
a disconnect, the pullup must be disabled in order to prevent powering the host through the pull-
up resistor.
When the host is disconnected and the transceiver is enabled, then DDP and DDM are floating.
This may lead to over consumption. A solution is to connect 330 KΩ pulldowns on DP and DM.
These pulldowns do not alter DDP and DDM signal integrity.
PIO
PIO
DDM
DDP
• the application detects all device states as defined in chapter 9 of the USB specification;
• to reduce power consumption the host is disconnected
• for line termination.
– pullup enable/disable
– VBUS monitoring
5V Bus Monitoring
Pullup Control
0: Enable
1: Disable
47 K
27 K
R
R
EXT
EXT
330 K
330 K
3V3
1.5K
2
3
Connector
6175K–ATARM–30-Aug-10
Type B
1
4

Related parts for AT91SAM7S64C-AU