71M6513-IGT/F Maxim Integrated Products, 71M6513-IGT/F Datasheet - Page 52

IC ENERGY METER 3PH 100-LQFP

71M6513-IGT/F

Manufacturer Part Number
71M6513-IGT/F
Description
IC ENERGY METER 3PH 100-LQFP
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6513-IGT/F

Mounting Style
SMD/SMT
Package / Case
LQFP-100
Program Memory Size
64 KB
Program Memory Type
Flash
Supply Current (max)
6.4 mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM
Quantity:
1 300
Part Number:
71M6513-IGT/F
Manufacturer:
Maxim Integrated
Quantity:
10 000
Part Number:
71M6513-IGT/F
Manufacturer:
MAXIM/美信
Quantity:
20 000
The data flow between CE and MPU is shown in Figure 17. In a typical application, the 32-bit compute engine (CE)
sequentially processes the samples from the voltage inputs on pins IA, VA, IB, VB, IC, and VC performing calculations to
measure active power (Wh), reactive power (VARh), A
accessed by the MPU, processed further and output using the peripheral devices available to the MPU.
Figure 18 shows the functional relationship between CE and MPU. The CE is controlled by the MPU via shared registers in the
I/O RAM and by registers in the CE DRAM. The CE outputs two interrupt signals to the MPU: CE_BUSY and XFER_BUSY,
which are connected to the MPU interrupt service inputs as external interrupts. CE_BUSY indicates that the CE is actively
processing data. This signal will occur once every multiplexer cycle. XFER_BUSY indicates that the CE is updating data to the
output region of the CE RAM. This will occur whenever the CE has finished generating a sum by completing an accumulation
interval determined by SUM_CYCLES * PRE_SAMPS samples. Interrupts to the MPU occur on the falling edges of the
XFER_BUSY and CE_BUSY signals.
Figure 19 shows the sequence of events between CE and MPU upon reset or power-up. In a typical application, the sequence
of events is as follows:
It is important to note that the length of the accumulation interval, as determined by N
PRE_SAMPS is not an exact multiple of 1000ms. For example, if SUM_CYCLES = 60, and PRE_SAMPS = 00 (42), the resulting
accumulation interval is:
This means that accurate time measurements require the RTC.
Page: 52 of 104
1)
2)
3)
4)
5)
Upon power-up, the MPU initializes the hardware, including disabling the CE
The MPU loads the code for the CE into the CE PRAM
The MPU loads CE data into the CE DRAM.
The MPU starts the CE by setting the CE_EN bit in the I/O RAM.
The CE then repetitively executes its code, generating results and storing them in the CE DRAM
A Maxim Integrated Products Brand
Samples
τ
=
Pulses
Processor
N
CE
f
I/O RAM (Configuration RAM)
ACC
© 2005-2011 Teridian Semiconductor Corporation
Pre-
S
=
Figure 17: MPU/CE Data Flow
CE/MPU Communication
32768
60
13
2
IRQ
Data
42
h, and V
Hz
Data Flow
=
2520
2
h for four-quadrant metering. These measurements are then
3-Phase Energy Meter IC
Processor
2520
MPU
Post-
.
62
Hz
=
71M6513/71M6513H
999
.
DATA SHEET
75
ms
ACC
Processed
Metering
, the product of SUM_CYCLES and
Data
AUGUST 2011