2866475 Phoenix Contact, 2866475 Datasheet

no-image

2866475

Manufacturer Part Number
2866475
Description
POWER SUPPLY 5A 12VDC
Manufacturer
Phoenix Contact
Series
Trior
Type
Industrialr
Datasheets

Specifications of 2866475

Voltage - Output
12V
Number Of Outputs
1
Power (watts)
60W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
100 ~ 240VAC
Mounting Type
DIN Rail
1st Output
12 VDC @ 5A
Size / Dimension
4.53" L x 1.26" W x 5.12" H (115mm x 32mm x 130mm)
Operating Temperature
-25°C ~ 70°C
Power (watts) - Rated
60W
Efficiency
83%
Approvals
cUL, EN, UL, VDE
Product
Switching
Commercial/medical
Commercial
Output Power Rating
60 W
Input Voltage
100 VAC to 240 VAC
Output Voltage (channel 1)
12 V
Output Current (channel 1)
5 A
Mounting Style
DIN Rail
Brand/series
TRIO
Configuration
Enclosed
Operation
Switching
Output
12 VDC @ 5 A
Phoenix Part Number
TRIO-PS/1AC/12DC/5
Power, Output
60 W
Primary Type
AC-DC
Voltage, Input
85 to 264 VAC
Voltage, Output
12 VDC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3rd Output
-
2nd Output
-
4th Output
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
277-2146
TRIO-PS/1AC/12DC/5
TRIO-PS/1AC/12DC/5
Primary switched power supply, 1-phase,
output current: 5 A
INTERFACE
Data Sheet
103347_en_00
1
TRIO POWER is the DIN-rail-mountable power supply unit
with basic functions. With an output voltage of 12 V DC,
24 V DC and 48 V DC and 1- and 3-phase versions with 60 W
or 960 W, it is particularly suited for use in series production
in mechanical engineering. The wide-range input and
international certification package allows worldwide
implementation.
The high MTBF of 500,000 h stands for high supply reliability.
The devices can be connected in parallel to increase the
capacity and redundancy.
The clear LED signaling and the device connection with
double terminal block for plus and minus for fast potential
distribution are further advantages of this device series. A
third terminal block simplifies the grounding on the secondary
side. All power supply units are idle proof and short circuit
proof and provide a regulated and adjustable output voltage.
Description
DANGER OF EXPLOSION!
Only remove equipment when it is disconnected and not in the potentially explosive area.
DANGER
Components with dangerously high voltage and high stored energy are located in the device!
Never carry out work on live parts!
Depending on the ambient temperature and the load, the housing can become very hot!
Make sure you always use the the latest documentation.
It can be downloaded at www.download.phoenixcontact.com.
A conversion table is available on the Internet at
www.download.phoenixcontact.com/general/7000_en_00.pdf.
© PHOENIX CONTACT - 05/2008
Features
Reliable power supply unit even at high ambient
temperatures
No load and short circuiting resistance
High dielectric strength
Can be used worldwide in all industrial sectors due to a
wide-range input and an international approval package

Related parts for 2866475

2866475 Summary of contents

Page 1

... Depending on the ambient temperature and the load, the housing can become very hot! Make sure you always use the the latest documentation. It can be downloaded at www.download.phoenixcontact.com. A conversion table is available on the Internet at www.download.phoenixcontact.com/general/7000_en_00.pdf. © PHOENIX CONTACT - 05/2008 Features – Reliable power supply unit even at high ambient temperatures – ...

Page 2

... Installation position...................................................................................................................... 10 Mounting on DIN rails .................................................................................................................. Assembly ...................................................................................................................................................................9 Removing...................................................................................................................................................................9 11 Connection to various systems.................................................................................................... 12 Input .......................................................................................................................................... Recommended backup fuse for mains protection ....................................................................................................10 13 Output ....................................................................................................................................... Protection of the secondary side ..............................................................................................................................11 14 Signaling ................................................................................................................................... 15 Function .................................................................................................................................... Output characteristic curve ......................................................................................................................................12 Thermal behavior .....................................................................................................................................................12 Parallel operation .....................................................................................................................................................12 Redundant operation ...............................................................................................................................................13 Increased performance ............................................................................................................................................13 103347_en_00 TRIO-PS/1AC/12DC PHOENIX CONTACT ...

Page 3

... Peak switching voltages Connection in parallel Connection in series Surge protection against internal surge voltages Resistance to reverse feed Signal output DC OK active Status display 103347_en_00 Type Order No. TRIO-PS/1AC/12DC/5 2866475 100 V AC ... 240 ... 264 ... 65 Hz Approx (120 V AC) Approx. 0.5 A (230 V AC) < < 0 > (120 V AC) > ...

Page 4

... EN 60721) EN 60204 / Surge voltage category III EN 61558-2-17 EN 60950/VDE 0805 (SELV) EN 61558-2-17 EN 50178/VDE 0160 (PELV) EN 60950 (SELV) EN 60204 (PELV) DIN VDE 0100-410 DIN VDE 0106-1010 DIN 57100-410 DIN VDE 0106-101 EN 61000-3-2 UL Listed UL 508 UL/C-UL Recognized UL 60950 TRIO-PS/1AC/12DC/5 4 PHOENIX CONTACT ...

Page 5

... Criterion B EN 61000-4-6 Input/output Level 3 - asymmetrical Frequency range 10 kHz ... 80 MHz Voltage 10 V Comments Criterion A EN 61000-4-11 Input (mains buffering > 10 ms) Comments Criterion B EN 55011 (EN 55022) Class B, area of application: Industry and residential EN 55011 (EN 55022) Class B, area of application: Industry and residential TRIO-PS/1AC/12DC/5 5 PHOENIX CONTACT ...

Page 6

... V AC ... 240 ... 264 V AC (derating < AC: 2.5% per Kelvin ... (characteristic (characteristic (characteristic B) Screw connection ± ... (> constant capacity (-25°C ... 70°C) Screw connection 9 mm TRIO-PS/1AC/12DC/5 2 [mm ] AWG [Nm] solid stranded Torque 0.2 - 2.5 0 0.4 - 0.5 0.2 - 2.5 0 0.4 - 0.5 PHOENIX CONTACT 6 ...

Page 7

... All output lines are dimensioned according to the maximum output current of the device or separately protected! Sufficient convection is guaranteed! ATTENTION: Danger if used improperly The power supply units are built-in devices. The device may only be installed and put into operation by qualified personnel. The corresponding national regulations must be observed. 103347_en_00 TRIO-PS/1AC/12DC/5 7 PHOENIX CONTACT ...

Page 8

... In order to guarantee sufficient convection, we recommend observing the following minimum distance to other modules vertical direction and horizontal direction. The power supply unit can be snapped onto all DIN rails in acc. with EN 60715 and must be mounted vertically (connecting terminal blocks on top and bottom). PHOENIX CONTACT 8 ...

Page 9

... Position the module with the DIN rail guide on the upper edge of the DIN rail, and snap it in with a downward motion. Removing Pull the snap lever open with the aid of a screwdriver and slide the module out at the lower edge of the DIN rail. B TN-C L PEN TRIO-PS/1AC/12DC PHOENIX CONTACT ...

Page 10

... The device must be installed in acc. with the regulations 60950. It must be possible to disconnect the device using a suitable isolating facility outside the power supply. Primary circuit mains protection, for example, is suitable for this purpose. Recommended backup fuse for mains protection Power circuit-breaker characteristic B (or identical function). TRIO-PS/1AC/12DC/5 10 PHOENIX CONTACT ...

Page 11

... The device is in operation, but there is a fault in the consumer, the current consumption is greater than I output is short circuited. The device is out of operation because there is no mains voltage, the fuse on the primary side has been triggered, or the device is faulty. TRIO-PS/1AC/12DC/5 or the N 11 PHOENIX CONTACT ...

Page 12

... The system makes it advisable to install a protective circuit at the output of each device when more than two power supply units are connected in parallel (e.g. decoupling diode or DC fuse). This prevents high reverse feed currents in the event of a secondary device fault. TRIO-PS/1AC/12DC the case PHOENIX CONTACT ...

Page 13

... PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany • Phone: +49-(0) 5235-3-00 103347_en_00 PHOENIX CONTACT • P.O.Box 4100 • Harrisburg • PA 17111-0100 • USA • Phone: +717-944-1300 Redundant operation I Redundant circuits are suitable for the supply of systems N + − ...

Related keywords