XBP09-XC009-DK Digi International, XBP09-XC009-DK Datasheet - Page 20

no-image

XBP09-XC009-DK

Manufacturer Part Number
XBP09-XC009-DK
Description
KIT STARTER XBEE PRO 900MHZ
Manufacturer
Digi International
Series
XBEE-PRO™r
Type
Transceiver, XBeePror

Specifications of XBP09-XC009-DK

Frequency
900MHz
Wireless Frequency
900 MHz
Operating Voltage
3.3 V
Output Power
100 mW
Antenna
U.FL, RPSMA, Whip
Operating Temperature Range
- 40 C to + 85 C
For Use With/related Products
Xbee-PRO Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
602-1133
Q4227731
XBP09-XC009-DK
Table 3‐01. AT Commands (The RF Module expects numerical values in hexadecimal. ʺdʺ denotes decimal equivalent.)
.NOTE: AT Commands issued without a parameter value are interpreted as queries and will returnthe currently stored parameter.
XBee‐PRO® XSC OEM RF Modules  
AT
Command
AT
BD
BT
CC
CD
CN
CS
CT
DB
DT
E0
E1
ER
FH
FL
FR
FT
GD
HP
HT
ID
LH
MK
NB
PC
PW
RE
RN
RO
RP
RR
RS
RT
SB
SH
SL
SM
ST
SY
TR
TT
VR
WR
3.2. Command Reference Table
Binary
Command
0x05 (5d)
0x15 (21d)
0x04 (4d)
0x13 (19d)
0x28 (40d)
0x09 (9d)
0x1F (31d)
0x06 (6d)
0x00 (0d)
0x0A (10d)
0x0B (11d)
0x0F (15d)
0x0D (13d)
0x07 (7d)
0x24 (36d)
0x10 (16d)
0x11 (17d)
0x03 (3d)
0x27 (39d)
0x0C (12d)
0x12 (18d)
0x23 (35d)
0x1E (30d)
0x1D (29d)
0x0E (14d)
0x19 (25d)
0x21 (33d)
0x22 (34d)
0x18 (24d)
0x1C (28d)
0x16 (22d)
0x36 (54d)
0x25 (37d)
0x26 (38d)
0x01 (1d)
0x02 (2d)
0x17 (23d)
0x1B (27d)
0x1A (26d)
0x14 (20d)
0x08 (8d)
AT Command Name
Guard Time After
Interface Data Rate
Guard Time Before
Command Sequence Character
DO3 Configuration
Exit AT Command Mode
DO2 Configuration
Command Mode Timeout
RSSI level in dBm of the most recent
packet
Destination Address
Echo Off
Echo On
Receive Error Count
Force Wake-up Initializer
Software Flow Control
Forces the module to Reset
Flow Control Threshold
Receive Good Count
Hopping Channel
Time before Wake-up Initializer
Module VID
Wake-up Initializer Timer
Address Mask
Parity
Power-up Mode
Pin Wake-up
Restore Defaults
Delay Slots
Packetization Timeout
RSSI PWM Timer
Retries
RSSI
DI2 Configuration
Stop Bits
Serial Number High
Serial Number Low
Sleep Mode
Time before Sleep
Time before Initialization
Transmit Error Count
Streaming Limit
Firmware Version
Write
© 2008 Digi International, Inc.
Range
0x02 – 0xFFFF [x 100 msec]
Standard baud rates:
0 – 6
Non-standard baud rates:
0x7D – 0xFFFF
2 – 0xFFFF [x 100 msec]
0x20 – 0x7F
0 - 4
-
0 – 4
0x02 – 0xFFFF [x 100 msec]
0 - 0x70 [read-only]
0 – 0xFFFF
-
-
0 – 0xFFFF
-
0 – 1
0 – (DI buffer – 0x11) [bytes]
0 – 0xFFFF
0 – 6
0 – 0xFFFF [x 100 msec]
User settable: 0x10 - 0x7FFF
Read-only: 0x8000 – 0xFFFF
0 – 0xFF [x 100 msec]
0 – 0xFFFF
0 – 4
0 – 1
0 – 1
-
0 – 0xFF [slots]
0 – 0xFFFF [x 200 µsec]
0 - 0x7F [x 100 msec]
0 – 0xFF
0x06 – 0x36 [read-only]
0 - 2
0 - 1
0 – 0xFFFF [read-only]
0 – 0xFFFF [read-only]
0, 1, 3 - 8
0x10 – 0xFFFF [x 100 msec]
0 – 0xFF [x 100 msec]
0 – 0xFFFF
0 – 0xFFFF [0 = disabled]
0 - 0xFFFF [read-only]
-
Command Category
Command Mode Options
Serial Interfacing
Command Mode Options
Command Mode Options
Serial Interfacing
Command Mode Options
Serial Interfacing
Command Mode Options
Diagnostics
Networking
Command Mode Options
Command Mode Options
Diagnostics
Sleep (Low Power)
Serial Interfacing
(Special)
Serial Interfacing
Diagnostics
Networking
Sleep (Low Power)
Networking
Sleep (Low Power)
Networking
Serial Interfacing
Command Mode Options
Sleep (Low Power)
(Special)
Networking
Serial Interfacing
Diagnostics
Networking
Diagnostics
Serial Interfacing
Serial Interfacing
Diagnostics
Diagnostics
Sleep (Low Power)
Sleep (Low Power)
Networking
Diagnostics
Networking
Diagnostics
(Special)
# Bytes
Returned
2
2
2
1
1
-
1
2
2
-
-
2
-
1
2
2
1
2
2
1
2
1
1
1
-
1
2
1
1
1
1
1
2
2
1
2
1
2
2
2
-
Factory
Default
0x0A (10d)
0x03 9600bps
0x0A (10d)
0x2B (“+”)
0
-
0
0xC8 (200d)
1
0
-
-
0
-
0
varies
0
0
0xFFFF
-
1
0xFFFF
0
0
0
-
0
0
0
0
-
0
0
-
-
0
0x64 (100d)
0 (disabled)
0
0xFFFF
-
-
     20

Related parts for XBP09-XC009-DK