X24-009NSC Digi International/Maxstream, X24-009NSC Datasheet - Page 23

no-image

X24-009NSC

Manufacturer Part Number
X24-009NSC
Description
MOD RF 2.4GHZ 9600BPS W/RPSMA
Manufacturer
Digi International/Maxstream
Datasheets

Specifications of X24-009NSC

Frequency
2.4GHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
17dBm
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
80mA
Current - Transmitting
150mA
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
CN (Exit AT Command Mode) Command
CO (DO3 Timeout) Command
CS (DO2 Configuration) Command
CT (Command Mode Timeout) Command
DC (Disconnect) Command
<Command Mode Options> CN Command is used
to explicitly exit AT Command Mode.
<Serial Interfacing> DO3 (Data Output 3) output
will return to default after no DI3 (Data Input 3)
status information is received during the timeout
period.
Use with CD = 1 or 2, DR = 1.
<Serial Interfacing> CS Command is used to
select the behavior of the DO2 (Data Output 2)
pin signal. This output can provide RS-232 flow
control, control the TX enable signal (for RS-485
or RS-422 operations), or set the default level for
the I/O line passing function.
By default, DO2 provides RS-232
Send) flow control.
<Command Mode Options> CT Command is used
to set the amount of time of inactivity before AT
Command Mode automatically terminates. After a
CT time of inactivity, the module exits AT
Command Mode and returns to Idle Mode. AT
Command Mode can also be exited manually
using the CN (Exit AT Command Mode)
Command.
<Networking & Security> DC Command is used
(when in Multi-Streaming Mode (MD = 1 or 2))
to explicitly force the disconnection of an active
exclusive connection. If MD = 1, the base
module will force the disconnection of an
exclusive connection. If MD = 2, the remote
module will send a “Disconnect Request Packet”
to the base module.
   © 2006 MaxStream, Inc. Confidential and Proprietary 
(Clear-to-
AT Command: ATDC
Binary Command: 0x37 (55 decimal)
Related Commands: CB (Connection Duration
Timeout), CE (Connection Inactivity Timeout),
MD (RF Mode)
Minimum Firmware Version Required: 4.30
AT Command: ATCN
Binary Command: 0x09 (9 decimal)
AT Command: ATCO
Binary Command: 0x2F (47 decimal)
Parameter Range: 0 – 0xFFFF [x 1 second]
Default Parameter Value: 3
Number of bytes returned: 2
Related Commands: CD (DO3 Configuration),
DR (DI3 Configuration)
Minimum Firmware Version Required: 4.30
AT Command: ATCS
Binary Command: 0x1F (31 decimal)
Parameter Range: 0 – 4
Default Parameter Value: 0
Number of bytes returned: 1
Related Commands: RT (DI2 Configuration),
TO (DO2 Timeout)
Minimum Firmware Version Required: 4.27D
AT Command: ATCT
Binary Command: 0x06 (6 decimal)
Parameter Range: 2 – 0xFFFF
Default Parameter Value: 0xC8 (200 decimal,
20 seconds)
Number of bytes returned: 2
Parameter
0
1
2
3
4
[x 100 milliseconds]
RS-232
RS-485 TX enable high
RS-485 TX enable low
Configuration
high
low
flow control
23 