XBP24-ASI-001 Digi International, XBP24-ASI-001 Datasheet - Page 15

MODULE XBEE 1MW W/RPSMA

XBP24-ASI-001

Manufacturer Part Number
XBP24-ASI-001
Description
MODULE XBEE 1MW W/RPSMA
Manufacturer
Digi International
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-ASI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
18dBm
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBP24-ASI-001J
Manufacturer:
XBEE
Quantity:
20 000
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
I/O Line Passing
Configuration Example
Virtual wires can be set up between XBee®/XBee-PRO® Modules. When an RF data packet is
received that contains I/O data, the receiving module can be setup to update any enabled outputs
(PWM and DIO) based on the data it receives.
Note that I/O lines are mapped in pairs. For example: AD0 can only update PWM0 and DI5 can
only update DO5. The default setup is for outputs not to be updated, which results in the I/O data
being sent out the UART (refer to the IU (Enable I/O Output) command). To enable the outputs to
be updated, the IA (I/O Input Address) parameter must be setup with the address of the module
that has the appropriate inputs enabled. This effectively binds the outputs to a particular module’s
input. This does not affect the ability of the module to receive I/O line data from other modules -
only its ability to update enabled outputs. The IA parameter can also be setup to accept I/O data
for output changes from any module by setting the IA parameter to 0xFFFF.
When outputs are changed from their non-active state, the module can be setup to return the out-
put level to it non-active state. The timers are set using the Tn (Dn Output Timer) and PT (PWM
Output Timeout) commands. The timers are reset every time a valid I/O packet (passed IA check)
is received. The IC (Change Detect) and IR (Sample Rate) parameters can be setup to keep the
output set to their active output if the system needs more time than the timers can handle.
Note: DI8 cannot be used for I/O line passing.
Applicable Commands: IA (I/O Input Address), Tn (Dn Output Timeout), P0 (PWM0 Configura-
tion), P1 (PWM1 Configuration), M0 (PWM0 Output Level), M1 (PWM1 Output Level), PT (PWM
Output Timeout), RP (RSSSI PWM Timer)
As an example for a simple A/D link, a pair of RF modules could be set as follows:
These settings configure the remote module to sample AD0 and AD1 once each every 20 ms. It
then buffers 5 samples each before sending them back to the base module. The base should then
receive a 32-Byte transmission (20 Bytes data and 12 Bytes framing) every 100 ms.
© 2009 Digi Internatonal, Inc.
Remote Configuration
MY = 0x5678
DL = 0x1234
IR = 0x14
D0 = 2
D1 = 2
IT = 5
IA = 0x5678 (or 0xFFFF)
Base Configuration
DL = 0x5678
MY = 0x1234
P0 = 2
P1 = 2
IU = 1
     15