XBP24-ASI-001 Digi International, XBP24-ASI-001 Datasheet - Page 66

MODULE XBEE 1MW W/RPSMA

XBP24-ASI-001

Manufacturer Part Number
XBP24-ASI-001
Description
MODULE XBEE 1MW W/RPSMA
Manufacturer
Digi International
Series
XBEE-PRO™r
Datasheets

Specifications of XBP24-ASI-001

Frequency
2.4GHz
Data Rate - Maximum
250kbps
Modulation Or Protocol
802.15.4
Applications
Home/Building Automation, Industrial Control, ZigBee™
Power - Output
18dBm
Sensitivity
-100dBm
Voltage - Supply
2.8 V ~ 3.4 V
Current - Receiving
55mA
Current - Transmitting
215mA @ 3.3V
Data Interface
PCB, Through Hole
Antenna Connector
RP-SMA
Operating Temperature
-40°C ~ 85°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Memory Size
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
XBP24-ASI-001J
Manufacturer:
XBEE
Quantity:
20 000
XBee®/XBee‐PRO®  RF Modules ‐ 802.15.4 ‐ v1.xEx [2009.09.23]
Antennas approved for use with the XBee®/XBee‐PRO® RF Modules (Cable‐loss is required)
* If using the RF module in a portable application (For example ‐ If the module is used in a handheld device and the antenna is less 
than 20cm from the human body when the device is operation): The integrator is responsible for passing additional SAR (Specific 
Absorption Rate) testing based on FCC rules 2.1091 and FCC Guidelines for Human Exposure to Radio Frequency Electromagnetic 
Fields, OET Bulletin and Supplement C. The testing results will be submitted to the FCC for approval prior to selling the integrated 
unit. The required SAR testing measures emissions from the module and how they affect the person.
RF Exposure
The preceding statement must be included as a CAUTION statement in OEM product manuals in order to alert users
of FCC RF Exposure compliance.
Part Number
A24-C1
A24-Y4NF
A24-Y6NF
A24-Y7NF
A24-Y9NF
A24-Y10NF
A24-Y12NF
A24-Y13NF
A24-Y15NF
A24-Y16NF
A24-Y16RM
A24-Y18NF
A24-F2NF
A24-F3NF
A24-F5NF
A24-F8NF
A24-F9NF
A24-F10NF
A24-F12NF
A24-F15NF
A24-W7NF
A24-M7NF
A24-P8SF
A24-P8NF
A24-P13NF
A24-P14NF
A24-P15NF
A24-P16NF
A24-P19NF
WARNING: To satisfy FCC RF exposure requirements for mobile transmitting devices, a separation distance of
20 cm or more should be maintained between the antenna of this device and persons during device operation.
To ensure compliance, operations at closer than this distance is not recommended. The antenna used for this
transmitter must not be co-located in conjunction with any other antenna or transmitter.
Type (Description)
Surface Mount
Yagi (4-element)
Yagi (6-element)
Yagi (7-element)
Yagi (9-element)
Yagi (10-element)
Yagi (12-element)
Yagi (13-element)
Yagi (15-element)
Yagi (16-element)
Yagi (16-element, RPSMA connector)
Yagi (18-element)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Fiberglass base station)
Omni-directional (Base station)
Omni-directional (Mag-mount base station)
Flat Panel
Flat Panel
Flat Panel
Flat Panel
Flat Panel
Flat Panel
Flat Panel
Europe (ETSI)
The XBee RF Modules have been certified for use in several European countries. For a complete
list, refer to www.digi.com
If the XBee RF Modules are incorporated into a product, the manufacturer must ensure compliance
of the final product to the European harmonized EMC and low-voltage/safety standards. A
Declaration of Conformity must be issued for each of these standards and kept on file as described
in Annex II of the R&TTE Directive.
© 2009 Digi Internatonal, Inc.
Gain
-1.5 dBi
6.0 dBi
8.8 dBi
9.0 dBi
10.0 dBi
11.0 dBi
12.0 dBi
12.0 dBi
12.5 dBi
13.5 dBi
13.5 dBi
15.0 dBi
2.1 dBi
3.0 dBi
5.0 dBi
8.0 dBi
9.5 dBi
10.0 dBi
12.0 dBi
15.0 dBi
7.2 dBi
7.2 dBi
8.5 dBi
8.5 dBi
13.0 dBi
14.0 dBi
15.0 dBi
16.0 dBi
19.0 dBi
Application* Min. Separation Required Cable-loss
Fixed/Mobile
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed/Mobile
Fixed/Mobile
Fixed/Mobile
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
20 cm
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
20 cm
20 cm
20 cm
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
2 m
-
8.1 dB
10.9 dB
11.1 dB
12.1 dB
13.1 dB
14.1 dB
14.1 dB
14.6 dB
15.6 dB
15.6 dB
17.1 dB
4.2 dB
5.1 dB
7.1 dB
10.1 dB
11.6 dB
12.1 dB
14.1 dB
17.1 dB
9.3 dB
9.3 dB
8.6 dB
8.6 dB
13.1 dB
14.1 dB
15.1 dB
16.1 dB
19.1 dB
     66

Related parts for XBP24-ASI-001