X09-019WNC Digi International/Maxstream, X09-019WNC Datasheet - Page 18

no-image

X09-019WNC

Manufacturer Part Number
X09-019WNC
Description
MOD RF 900MHZ 19.2K W/WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019WNC

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
MaxStream’s X-CTU
Software facilitates
module programming.
To install, double-click
the “setup_X-CTU.exe”
file that is located on
the MaxStream CD &
on the Internet.
(www.maxstream.net)
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
3. RF Module Configuration 
3.1. Hands-on Programming Examples
3.1.1. AT Command Example
3.1.2. Binary Command Example
To Send AT Commands (Using the Terminal tab of MaxStream’s X-CTU Software)
To Send Binary Commands:
For information about entering and exiting AT and Binary Command Modes, refer to the
Command Mode section [p16].
Example: Both of the following examples change the module’s destination address to 0x1A0D and
save the new address to non-volatile memory.
Method 1 (One line per command)
Method 2 (Multiple commands on one line)
Note: In order to use a host PC and the X-CTU Software Terminal tab to send data to the module, PC
com port settings must match the baud, parity & stop bit parameters stored in the module.
Use the “PC Settings” tab to configure PC com port settings to match module parameter values.
Example: Use binary commands to change the XStream Module’s destination address to 0x1A0D
and save the new address to non-volatile memory.
1.
2.
3.
4.
Note:
must be disabled as
   © 2006 MaxStream, Inc. Confidential and Proprietary 
RT Command must be set to “1” in AT Command Mode to enable binary programming.
Assert CMD (Pin 5 is driven high).
Send Bytes (parameter bytes must be 2 bytes long):
De-assert CMD (Pin 5 is driven low)
Send AT Command
+++
ATDT <Enter>
ATDT1A0D <Enter>
ATWR <Enter>
ATCN <Enter>
Send AT Command
+++
ATDT <Enter>
ATDT1A0D,WR,CN <Enter>
(pin 1) is de-asserted high when commands are being executed. Hardware flow control
00
0D
1A
08
will hold off parameter bytes.
(Enter Binary Command Mode)
(Send DT (Destination Address) Command)
(Least significant byte of parameter bytes)
(Most significant byte of parameter bytes)
(Send WR (Write) Command)
(Exit Binary Command Mode)
System Response
OK <CR> (Enter into Command Mode)
current Destination Address <CR> (Read)
OK <CR> (Change destination address)
OK <CR> (Write to non-volatile memory)
OK <CR> (Exit Command Mode)
System Response
OK <CR> (Enter into Command Mode)
current Destination Address <CR> (Read)
OK <CR> (Execute commands)
18 