X09-019WNC Digi International/Maxstream, X09-019WNC Datasheet - Page 20

no-image

X09-019WNC

Manufacturer Part Number
X09-019WNC
Description
MOD RF 900MHZ 19.2K W/WIRE ANT
Manufacturer
Digi International/Maxstream
Series
XStream™r
Datasheets

Specifications of X09-019WNC

Frequency
900MHz
Data Rate - Maximum
19.2kbps
Modulation Or Protocol
FSK
Power - Output
100mW
Sensitivity
-110dBm
Voltage - Supply
5V
Current - Receiving
50mA
Current - Transmitting
140mA
Data Interface
PCB, Through Hole
Antenna Connector
On-Board, Wire Antenna
Operating Temperature
0°C ~ 70°C
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Applications
-
Memory Size
-
XStream™ OEM RF Module – Product Manual v5.x00 [2006.02.24] 
3.3. XStream Command Descriptions
AM (Auto-set MY) Command
AT (Guard Time After) Command
BD (Interface Data Rate) Command
Command descriptions in this section are listed alphabetically. Command categories are
designated within “< >” symbols that follow each command title. XStream Modules expect
parameter numerical values in hexadecimal (designated by the “0x” prefix).
<Networking & Security> AM Command is used
to automatically set the MY (Source Address)
parameter from the factory-set module serial
number. The address is formed with bits 29, 28 and 13-0 of the serial number (in that order).
<Command Mode Options> AT Command is used
to set the DI time-of-silence that follows the AT
command sequence character (CC Command).
By default, AT Command Mode will activate after
one second of silence.
Refer to the AT Commands section [p16] to view
the default AT Command Mode Sequence.
<Serial Interfacing> BD Command allows the
user to adjust the UART interface data rate and
thus modify the rate at which serial data is sent
to the RF module. The new baud rate does not
take effect until the CN command is issued. The
RF data rate is unaffected by the BD parameter.
Most applications will require one of the seven
standard baud rates; however, non-standard
baud rates are also supported.
Note: If the interface data rate is set to exceed
the fixed RF data rate of the module,
control may need to be implemented as
described in the Pin Signals [p6], Flow Control
[p10] and CS (DO2 Configuration) sections.
Non-standard Interface Data Rates: When
parameter values outside the range of standard
interface data rates are sent, the closest rate represented by the number is stored in the BD
register. For example, a rate of 19200 bps can be set by sending the following command line
"ATBD4B00". NOTE: When using MaxStream’s X-CTU Software, non-standard interface data rates
can only be set and read using the X-CTU ‘Terminal’ tab.
When the BD command is sent with a non-standard interface data rate, the UART will adjust to
accommodate the requested interface rate. In most cases, the clock resolution will cause the
stored BD parameter to vary from the parameter that was sent (refer to the table below).
Reading the BD command (send "ATBD" command without an associated parameter value) will
return the value that was actually stored in the BD register.
Table 3‐02. Parameter Sent vs. Parameter Stored 
   © 2006 MaxStream, Inc. Confidential and Proprietary 
BD Parameter Sent (HEX)
1C200
12C
0
4
7
Interface Data Rate (bps)
flow
115,200
115,200
19,200
1200
300
AT Command: ATAT
Binary Command: 0x05 (5 decimal)
Parameter Range: 0x02 – 0xFFFF
Number of bytes returned: 2
Default Parameter Value: 0x0A (10 decimal)
Related Commands: BT (Guard Time Before),
CC (Command Sequence Character)
AT Command: ATBD
Binary Command: 0x15 (21 decimal)
Parameter Range (Standard baud rates): 0 – 6
(Non-standard baud rates): 0x7D – 0xFFFF
Number of bytes returned: 2
Default Parameter Value: Set to equal module’s
factory-set RF data rate.
Related Commands: CN (Exit Command Mode)
Minimum firmware version required: 4.2B
(Custom baud rates not previously supported.)
AT Command: ATAM
Binary Command: 0x3A (58 decimal)
Minimum firmware version required: 4.40
Parameter
0
1
2
3
4
5
6
BD Parameter Stored (HEX)
[x 100 milliseconds]
Configuration (bps)
1B207
12B
0
4
7
19200
38400
57600
1200
2400
4800
9600
20 