CM200DY-12NF Powerex Inc, CM200DY-12NF Datasheet
CM200DY-12NF
Specifications of CM200DY-12NF
Available stocks
Related parts for CM200DY-12NF
CM200DY-12NF Summary of contents
Page 1
... Applications: □ AC Motor Control □ UPS □ Battery Powered Supplies Ordering Information: Example: Select the complete part module number you desire from the table below -i.e. CM200DY-12NF is a 600V (V ), CES 200 Ampere Dual IGBTMOD™ Power Module. Type Current Rating V CES ...
Page 2
... GE C res t d(on 300V 200A 15V, R d(off) GE1 GE2 t Inductive Load f t Switching Operation 200A does not exceed T j Symbol CM200DY-12NF T –40 to 150 j T –40 to 125 stg V 600 CES V 20 GES I 200 C I 400 200 E I 400 650 C — 30 — 40 — ...
Page 3
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM200DY-12NF Dual IGBTMOD™ NF-Series Module 200 Amperes/600 Volts Thermal and Mechanical Characteristics, T Characteristics Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Thermal Resistance, Junction to Case Contact Thermal Resistance External Gate Resistance ...
Page 4
... Powerex, Inc., 200 E. Hillis Street, Youngwood, Pennsylvania 15697-1800 (724) 925-7272 CM200DY-12NF Dual IGBTMOD™ NF-Series Module 200 Amperes/600 Volts REVERSE RECOVERY CHARACTERISTICS (TYPICAL 300V ±15V 3 25°C j Inductive Load EMITTER CURRENT (AMPERES) E SWITCHING LOSS VS. GATE RESISTANCE (TYPICAL 300V ±15V 200A 125°C ...