E8Y-A5Y-R Omron, E8Y-A5Y-R Datasheet - Page 3

no-image

E8Y-A5Y-R

Manufacturer Part Number
E8Y-A5Y-R
Description
SENSOR PRESSURE DIFF 0-5KPA NPN
Manufacturer
Omron
Series
E8Yr
Datasheet

Specifications of E8Y-A5Y-R

Pressure Type
Differential
Operating Pressure
0.73 PSI, 5 kPa
Port Size
Male, 1/8" (3.175mm) Pipe Threads
Output
Digital
Voltage - Supply
12 V ~ 24 V
Termination Style
Cable
Operating Temperature
-10°C ~ 55°C
Package / Case
Module
Mounting Style
Screw
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 10 C
Operating Supply Voltage
15 V, 18 V
Output Voltage
30 V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
E8YA5YR
E8Y
Application Examples
Nomenclature
Display
1 Numerical value/menu indication
Displays the measured pressure and some menu
settings.
2 Unit
Shows the measuring unit. Unit currently in use is
illuminated.
3 OUT 1 indication LED
In measurement mode, it lights when OUT 1 output is on.
In setting mode, it flashes when OUT 1 is being set.
4 OUT 2 indication LED
In measurement mode, it lights when OUT 2 output is on.
In setting mode, it flashes when OUT 2 is being set.
DETECTION OF
FILTER
CLOGGING
E8Y PRESSURE SENSOR
3
4
Filter
E8Y
5
6
x10-
3
EXHAUST FAN
ROTATION
DETECTION
psi
7
1
2
E8Y
4
Lead Frame
Operation key
5 ADJ
In measurement mode, it adjusts the Zero Point. In
setting mode, it shifts to measurement mode.
6 MODE
Selects the current number setting or menu option.
7 UP/DOWN
In measurement mode, pushing the DOWN key displays
the ON and OFF points of OUT 1; pushing the UP key
displays the ON and OFF points of OUT 2. In setting
mode, the UP and DOWN keys increase or decrease the
numeric value, respectively, or scroll through the menu
options.
DETECTION OF
FLOW
N
2
E8Y- -F
AIR FLOW
CONTROL
E8Y- -F
E8Y