A22L-HY-T1-01A Omron, A22L-HY-T1-01A Datasheet - Page 34

no-image

A22L-HY-T1-01A

Manufacturer Part Number
A22L-HY-T1-01A
Description
SWITCH PB ILLUM RND ALT SPST YEL
Manufacturer
Omron
Series
A22r
Type
Illuminatedr
Datasheet

Specifications of A22L-HY-T1-01A

Circuit
SPST-NC
Switch Function
On-Off
Contact Rating @ Voltage
10A @ 110VAC
Actuator Type
Round, Half Guard
Illumination Type, Color
LED, Yellow
Illumination Voltage (nominal)
110 VAC
Mounting Type
Panel Mount
Termination Style
Screw Terminal
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
A22LHYT101A
Mounting Precautions
Wiring
Soldering
Typical Soldering Example
• Perform wiring so that the lead wires will not be caught on other objects
• With miniature Switches, the gap between the terminals is very
• There are two methods for soldering the Switch: hand soldering and
Hand soldering
Automatic
soldering
• Do not use soldering flux that contains chlorine. Doing so may
as this will cause stress on the Switch terminals. Wire the Switch so
that there is slack in the lead wires and fix lead wires at intermediate
points. If the panel to which the Switch is mounted needs to be opened
and closed for maintenance purposes, perform wiring so that the
opening and closing of the panel will not interfere with the wiring.
narrow. Use protective or heat-absorbing tubes to prevent burning
of the wire sheath or shorting.
automatic soldering. In addition, automatic soldering itself can be
divided into two types : dip soldering and reflow soldering. Use the
soldering method appropriate for the mounting method.
result in metal corrosion.
Method
Dip
soldering
Reflow
soldering
http://www.ia.omron.com/
Soldering iron
Jet soldering bath
Dip soldering bath
Infrared reflow (IR)
soldering bath
Vapor-phase (VPS)
reflow soldering bath
Soldering device
Protective tube
Small quantities
Different materials
Lead wire terminals
Large quantities of
discrete terminals
Large quantities
of miniature SMD
terminals
Application
Technical Guide for Pushbutton Switches
Termina
• Perform hand soldering using the appropriate soldering iron.
• With the exception of PCB-mounting Switches, when performing
• Leave a gap of at least 1 mm between the soldered parts and the
• When applying flux using a brush, use a sponge soaked in flux as
hand soldering, hold the Switch so that the terminals point
downwards so that flux does not get inside the Switch.
surface of the case so that flux does not get inside the Switch.
shown below. Do not apply more than is necessary. Also, apply the
flux with the PCB inclined at an angle of less than 80° so that flux
does not flow onto the mounting surface of the Switch.
l
Lead wire
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Large-capacity
soldering iron
Sponge
soaked in flux
Flux
Lead wire
Terminal
Solder
Case
Brush
Small-capacity
soldering iron
used for a long
time
Brush
80 °
max.
1 mm min.
Perform soldering for
between 3 to 5 s with
a suitable soldering iron.
C-5

Related parts for A22L-HY-T1-01A