DLP-RF2-Z-G DLP Design Inc, DLP-RF2-Z-G Datasheet - Page 4

Zigbee / 802.15.4 Modules & Development Tools TTL SERIAL INTERFACE MODULE

DLP-RF2-Z-G

Manufacturer Part Number
DLP-RF2-Z-G
Description
Zigbee / 802.15.4 Modules & Development Tools TTL SERIAL INTERFACE MODULE
Manufacturer
DLP Design Inc
Datasheet

Specifications of DLP-RF2-Z-G

Wireless Frequency
2.4 GHz
Interface Type
2 Wire Serial
For Use With/related Products
MC13193, MC9S08GT60
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Additionally, if JP1 is shorted at power up (or reset), the default values for the transceiver
settings are restored, and the checksum is recalculated and rewritten. Again, values in the user
area are preserved.
The following table outlines the usage of the reserved EEPROM locations. These values are
read at power up, reset, or via SIPP firmware:
EEPROM CONTENTS
2.3 Command Set
This Command Set is a feature of the SIPP firmware and, as such, is only available if using the
DLP-RF2-Z with its firmware as shipped from DLP Design.
Rev 1.8 (November 2005)
Byte Description
31
0
1
2
3
4
5
6
7
8
9
My ID MSB
My ID LSB
Transceiver Channel
RF Transmit Power
Sleep Time Length MSB
(DLP-RF2-Z Low-Power
Mode Only)
Sleep Time Length LSB
Wake from Sleep, Host
Command Timeout after
Check-in (DLP-RF2-Z in
Low-Power Mode Only)
Baud Rate for RF2-Z
Serial Host Controller )
Port Pin Bit Field
(DLP-RF2/RF2-Z Only)
DLP-RF2-Z Available
Features
(DLP-RF2-Z Only)
Checksum
Options
Range: 1-65,535
0-15 (2.405GHz to 2.480GHz)
0-15 (-16.6 to +3.5dBm into the balun)
Range: 1-65,535; 5-second increments,
3.8 days max
For Example: 1=5 seconds, 12=1
minute, 120=10 minutes, 720=1 hour,
17,280=1day
1-128 half-seconds
0-2400; 1-4800; 2-9600; 3-14400;
4-19200; 5-38400; 6-128000;
7-250000
0x00-0xFF
DLP-RF2: (A6B6B5B4 B3B2B1B0)
DLP-RF2-Z: (A6B6A2A1 B3B2B1B0)
Bit 7 – Measures battery voltage
Bit 6 – Temperature sensor
Bit 5 – Relays
Bit 4 – Reserved
Bit 3 – Reserved
Bit 2 – Reserved
Bit 1 – Reserved
Bit 0 – Reserved
EX-OR of bytes 0-30
4
DLP-RF2-Z  DLP Design, Inc.
Default Reset
1 for RF1; 2 for RF2-
Z
0 reserved for
broadcast commands
7 (2.440 GHz)
15 (+3.5dBm -Max
Power)
5 seconds
2 (4 half-second
intervals)
2 (9600 baud)
0x80 (A6 monitored)
All bits cleared; no
features available
Calculated

Related parts for DLP-RF2-Z-G