Varistors 175volts 8000A

B72220S0171K101

Manufacturer Part NumberB72220S0171K101
DescriptionVaristors 175volts 8000A
ManufacturerEPCOS Inc
B72220S0171K101 datasheet
 


Specifications of B72220S0171K101

ProductMOVVoltage Rating Dc225 V
Voltage Rating Ac175 VClamping Voltage455 V
Peak Surge Current8 KASurge Energy Rating98 J
Capacitance1000 pFOperating Temperature Range- 40 C to + 85 C
MountingThrough HoleDimensions21.5 mm Dia. x 25.5 mm L
Tolerance10 %Lead Free Status / RoHS StatusLead free / RoHS Compliant
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Page 18/36

Download datasheet (292Kb)Embed
PrevNext
Leaded varistors
StandarD series
Reliability data
Test
Test methods/conditions
Varistor voltage
The voltage between two terminals with
the specified measuring current applied
is called V
Clamping voltage
The maximum voltage between two
terminals with the specified standard
impulse current (8/20 µs) applied.
Max. AC operating voltage
CECC 42 000, test 4.20
1000 h at UCT
After having continuously applied
the maximum allowable voltage at UCT
±2 °C for 1000 h, the specimen shall be
stored at room temperature and normal
humidity for 1 to 2 h.
Thereafter, the change of V
measured.
Surge current derating,
CECC 42 000, test C 2.1
8/20 µs
100 surge currents (8/20 µs), unipolar,
interval 30 s, amplitude corresponding
to derating curve for 100 impulses at
20 µs
Surge current derating,
CECC 42 000, test C 2.1
2 ms
100 surge currents (2 ms), unipolar,
interval 120 s, amplitude corresponding
to derating curve for 100 impulses at
2 ms
Electric strength
CECC 42 000, test 4.7
Metal balls method, 2500 V
The varistor is placed in a container
holding 1.6 ±0.2 mm diameter metal
balls such that only the terminations of
the varistor are protruding.
The specified voltage shall be applied
between both terminals of the speci-
men connected together and the elec-
trode inserted between the metal balls.
Please read Cautions and warnings and
Important notes at the end of this document.
Requirement
To meet the specified value.
(1 mA
@ 0.2 … 2 s).
v
DC
To meet the specified value.
∆V/V (1 mA)
|
shall be
v
∆V/V (1 mA)
|
(measured in direction
of surge current)
No visible damage
∆V/V (1 mA)
|
(measured in direction
of surge current)
No visible damage
No breakdown
, 60 s
RMS
18
11/07
≤10%
|
≤10%
|