DS760SL-3 Emerson Network Power, DS760SL-3 Datasheet - Page 4

no-image

DS760SL-3

Manufacturer Part Number
DS760SL-3
Description
POWER SUPPLY AC/DC 12V 760W
Manufacturer
Emerson Network Power
Series
DS760r
Datasheet

Specifications of DS760SL-3

Operating Temperature
-10°C ~ 50°C
Power (watts) - Rated
748W
Efficiency
91%
Approvals
CB, CCC, CSA, cUL, UL, VDE
Line Regulation
1%
Load Regulation
1%
Voltage - Output
12V
Number Of Outputs
1
Power (watts)
760W
Applications
Commercial
Power Supply Type
Switching (Closed Frame)
Voltage - Input
90 ~ 264VAC
Mounting Type
Rack Mount
1st Output
12 VDC @ 62.3A
Size / Dimension
12.68" L x 2.15" W x 1.57" H (322mm x 54.5mm x 40mm)
Input Voltage
90 to 264V
Output Voltage
12V
Input Frequency
47 to 63Hz
Screening Level
Commercial
Product Height (mm)
40mm
Operating Temperature Min Deg. C
-10C
Operating Temperature Max Deg. C
50C
Mounting Style
Desktop
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
2nd Output
-
3rd Output
-
4th Output
-
Lead Free Status / Rohs Status
Compliant
Other names
454-1434
Outputs - All Models
PSON #
Item
Tvout_rise
Tvout_rise
Tsb_on_delay
Tac_on_delay
Tvout_holdup
Tpwok_holdup
Tpson_on_delay Delay from PSON# active to output voltages within regulation limits.
Tpson_pwok
Tacok_delay
Tpwok_on
Tpwok_off
Tpwok_low
Tsb_vout
The PSON# signal is required to remotely turn on/off the power supply. PSON# is an active low signal that
turns on the +12 Vdc power rail. When this signal is not pulled low by the system, or left open, the +12
Vdc output turns off. The 5.0 Vsb output remains on. This signal is pulled to a standby voltage by a pull-
up resistor internal to the power supply. The power supply fan(s) shall operate at the lowest speed.
Description
+12 Output rise time
5.0 Vsb output rise time
Delay from AC being applied to 5.0 Vsb being within regulation.
Delay from AC being applied to all output voltages being within regulation.
Time all output voltages, including 5.0 Vsb, stay within regulation after loss of
AC.
Delay from loss of AC to de-assertion of PWOK
Delay from PSON# de-active to PWOK being de-asserted.
Delay from loss of AC input to de-assertion of ACOK#.
Delay from output voltages within regulation limits to PWOK asserted at turn
on.
Delay from PWOK de-asserted to 12 Vdc or 5.0 Vsb dropping out of regulation
limits.
Duration of PWOK being in the de-asserted state during an off/on cycle using AC
or the PSON# signal.
Delay from 5.0 Vsb being in regulation to 12 Vdc being in regulation at AC turn
on.
Signal Type
PSON# = Low
PSON# = Open
Logic level low (power supply ON)
Logic level high (power supply OFF)
Source current, Vpson = low
Power up delay: Tpson_on_delay
Turn On/Off Timing
Accepts an open collector/drain input
from the system. Pulled-up to the 5.0
Vsb located in power supply.
5 msec
2.0V
MIN
0V
OFF
ON
200 msec
4.125V
4 mA
MAX
0.8V
Embedded Power for
Business-Critical Continuity
Min
100
100
10
12
50
10
50
1
5
1
1500
3000
2500
1000
1000
1000
Max
300
100
50
Rev. 03.15.11_80
Units
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
mSec
DS760SL Series
4 of 8