LM75CIMX-5 National Semiconductor, LM75CIMX-5 Datasheet - Page 10

IC, TEMPERATURE SENSOR 9BIT, ± 2°C, SOP8

LM75CIMX-5

Manufacturer Part Number
LM75CIMX-5
Description
IC, TEMPERATURE SENSOR 9BIT, ± 2°C, SOP8
Manufacturer
National Semiconductor
Datasheet

Specifications of LM75CIMX-5

Ic Output Type
Digital
Sensing Accuracy Range
± 2°C
Supply Current
250µA
Supply Voltage Range
3V To 5.5V
Resolution (bits)
9bit
Sensor Case Style
SOP
No. Of Pins
8
Termination Type
SMD
Accuracy %
3°C
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM75CIMX-5
Manufacturer:
NSC
Quantity:
5 000
Part Number:
LM75CIMX-5
Manufacturer:
NS
Quantity:
1 923
Part Number:
LM75CIMX-5
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM75CIMX-5
Quantity:
2 500
Company:
Part Number:
LM75CIMX-5
Quantity:
749
Company:
Part Number:
LM75CIMX-5
Quantity:
749
Part Number:
LM75CIMX-5.0
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM75CIMX-5/NOPB
Manufacturer:
NS
Quantity:
250
Part Number:
LM75CIMX-5/NOPB
Manufacturer:
NS/国半
Quantity:
20 000
www.national.com
Note 15: These interrupt mode resets of O.S. occur only when LM75 is read or placed in shutdown. Otherwise, O.S. would remain active indefinitely for any
event.
1.4 TEMPERATURE DATA FORMAT
Temperature data can be read from the Temperature, T
Point, and T
Set Point, and T
represented by a 9-bit, two's complement word with an LSB
(Least Significant Bit) equal to 0.5°C:
1.5 SHUTDOWN MODE
Shutdown mode is enabled by setting the shutdown bit in the
Configuration register via the I
duces power supply current significantly. See specified qui-
escent current specification in the electrical tables. In Interrupt
mode O.S. is reset if previously set and is undefined in Com-
parator mode during shutdown. The I
active. Activity on the clock and data lines of the I
slightly increase shutdown mode quiescent current. T
T
ten to in shutdown mode.
HYST
Temperature
+125°C
, and Configuration registers can be read from and writ-
+0.5°C
−0.5°C
+25°C
−25°C
−55°C
0°C
HYST
HYST
Set Point registers; and written to the T
Set Point registers. Temperature data is
0 1111 1010
0 0011 0010
0 0000 0001
0 0000 0000
1 1111 1111
1 1100 1110
1 1001 0010
Binary
2
Digital Output
C bus. Shutdown mode re-
FIGURE 4. O.S. Output Temperature Response Diagram
2
C interface remains
0FAh
1CEh
1FFh
2
032h
001h
000h
192h
Hex
C bus may
OS
Set
OS
OS
,
10
For the LM75B, the TIMEOUT feature is turned off in Shut-
down Mode.
1.6 FAULT QUEUE
A fault queue of up to 6 faults is provided to prevent false
tripping of O.S. when the LM75 is used in noisy environments.
The number of faults set in the queue must occur consecu-
tively to set the O.S. output.
1.7 COMPARATOR/INTERRUPT MODE
As indicated in the O.S. Output Temperature Response Dia-
gram,
either Comparator or Interrupt mode. The most important dif-
ference is that in Interrupt mode the O.S. will remain set
indefinitely once it has been set. To reset O.S. while in Inter-
rupt mode, perform a read from any register in the LM75.
1.8 O.S. OUTPUT
The O.S. output is an open-drain output and does not have
an internal pull-up. A “high” level will not be observed on this
pin until pull-up current is provided from some external
source, typically a pull-up resistor. Choice of resistor value
depends on many system factors but, in general, the pull-up
resistor should be as large as possible. This will minimize any
errors due to internal heating of the LM75. The maximum re-
sistance of the pull up, based on LM75 specification for High
Level Output Current, to provide a 2V high level, is 30 kΩ.
Figure
4, the events that trigger O.S. are identical for
30099807

Related parts for LM75CIMX-5