CS61584A-IQ5Z Cirrus Logic Inc, CS61584A-IQ5Z Datasheet - Page 36

no-image

CS61584A-IQ5Z

Manufacturer Part Number
CS61584A-IQ5Z
Description
IC,Line Interface,QFP,64PIN,PLASTIC
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CS61584A-IQ5Z

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CS61584A-IQ5Z
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
Part Number:
CS61584A-IQ5Z
Manufacturer:
CIRRUS
Quantity:
20 000
Part Number:
CS61584A-IQ5ZR
Manufacturer:
Cirrus Logic Inc
Quantity:
10 000
36
10.16 Exit1-IR State
This is a temporary state. While in this state, if J-
TMS is held high, a rising edge applied to J-TCK
causes the controller to enter the Update-IR state,
which terminates the scanning process. If J-TMS is
held low and a rising edge is applied to J-TCK, the
controller enters the Pause-IR state. The test data
register selected by the current instruction retains
its previous value and the instruction does not
change during this state.
10.17 Pause-IR State
The pause state allows the test controller to tempo-
rarily halt the shifting of data through the instruc-
tion register. The test data register selected by the
current instruction retains its previous value and
the instruction does not change during this state.
The controller remains in this state as long as J-
TMS is low. When J-TMS goes high and a rising
edge is applied to J-TCK, the controller moves to
the Exit2-IR state.
10.18 Exit2-IR State
This is a temporary state. While in this state, if J-
TMS is held high, a rising edge applied to J-TCK
causes the controller to enter the Update-IR state,
which terminates the scanning process. If J-TMS is
held low and a rising edge is applied to J-TCK, the
controller enters the Shift-IR state.
36
DS261PP5
The test data register selected by the current in-
struction retains its previous value and the instruc-
tion does not change during this state.
10.19 Update-IR State
The instruction shifted into the instruction register
is latched into the parallel output from the shift-reg-
ister path on the falling edge of J-TCK. When the
new instruction has been latched, it becomes the
current instruction. The test data registers selected
by the current instruction retain their previous val-
ue.
10.20 JTAG Application Examples
Figures 25 and 26 illustrate examples of updating
the instruction and data registers during JTAG op-
eration.
CS61584A
CS61584A
DS261PP5
DS261F1

Related parts for CS61584A-IQ5Z