LC1D09BD SQUARE D, LC1D09BD Datasheet

no-image

LC1D09BD

Manufacturer Part Number
LC1D09BD
Description
CONTACTOR, 3PST-NO, 24VDC, 20A, DIN RAIL
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D09BD

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Width
45mm
Relay Terminals
Screw Clamp
Contact Voltage Ac Max
600V
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
25A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
25A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Catalog
04
TeSys™ IEC-Style
Contactors and Starters
File 8502
CONTENTS
Description
TeSys IEC Contactors and Starters Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . 3
TeSys K-line Mini-contactors, Overload Relays, and Accessories . . . . . . . . . . . . . . 37
TeSys D-line Contactors, Enclosed Starters Overload Relays, and Accessories . . . 77
TeSys F-line Contactors, Overload Relays, and Accessories . . . . . . . . . . . . . . . . . 179
Catalog Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247
Page

Related parts for LC1D09BD

LC1D09BD Summary of contents

Page 1

... Contactors and Starters File 8502 CONTENTS Description TeSys IEC Contactors and Starters Selection Guide TeSys K-line Mini-contactors, Overload Relays, and Accessories . . . . . . . . . . . . . . 37 TeSys D-line Contactors, Enclosed Starters Overload Relays, and Accessories . . . 77 TeSys F-line Contactors, Overload Relays, and Accessories . . . . . . . . . . . . . . . . . 179 Catalog Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 ...

Page 2

...

Page 3

... Catalog 04 TeSys™ IEC-Style Contactors and Starters Selection Guide File 8502 Selection Guide CONTENTS Description Technical Information Product Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Product Approvals Protective Treatment According to Climatic Environment . . . . . . . . . . . . . . . . . . . . 10 Degrees of Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Kilowatt Motor Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Horsepower Motor Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Contactor Selection Guide Definitions of Utilization Categories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Contactor Selection Guide for Utilization Category AC Contactor Selection Guide for Utilization Category AC-1 ...

Page 4

... Under the “Technical Union of Electricity” (UTE), the French version of the corresponding European standard carries a double notation: European reference (NF EN …) and classification (C …). In addition, the standard NF EN 60947-4-1 relating to motor contactors and starters, effectively constitutes the French version of the European standard EN 60947-4-1 and carries the UTE classification C 63-110 ...

Page 5

The manufacturer is obliged to ensure that all measures are taken to provide conformity to the regulations of the particular Directive applicable to his product general rule, the manufacturer certifies conformity to the essential requirements of the Directive(s) ...

Page 6

... Product Approvals The table below shows the approvals obtained or pending with the various approvals authorities as of 5/15/1995. For more detailed information, please consult your Local Square D Field Sales Office. Existing and Pending Approval of Automation System Components (except control and signalling units) ...

Page 7

Existing and Pending Approval of Automation System Components (except control and signalling units) Approvals Standard Version X : Approved O : Approval pending Special Version + : Approved ASE CSA DEMKO Ø : Approval pending Switzer Canada Denmark land AK5 ...

Page 8

Technical Information: Product Approvals Existing and Pending Approval of Automation System Components (except control and signalling units) Approvals Standard Version X : Approved O : Approval pending Special Version + : Approved ASE CSA DEMKO Ø : Approval pending Switzer ...

Page 9

Existing and Pending Approval of Automation System Components (except control and signalling units) Approvals Standard Version X : Approved O : Approval pending Special Version + : Approved ASE CSA DEMKO Ø : Approval pending Switzer Canada Denmark land XBLA ...

Page 10

... Components mounted inside the enclosure must have a “TC” finish. • If the equipment switched off for long periods, a heater must be provided (0.2 to 0.5 kW per square decimeter / 15.5 square inch of enclosure), switched on automatically when the equipment is turned off. This heater keeps the inside of the enclosure at a temperature slightly higher than the ...

Page 11

For pilot devices, the use of “TC” treatment can be extended to outdoor use provided the enclosure is made of light alloys, zinc alloys, or plastic material. In this case essential to ensure that the degree of ...

Page 12

Technical Information: Degrees of Protection Technical Information: Degrees of Protection IEC Publication 60529 Classification of Degrees of Protection Provided by Enclosures provides a system for specifying the enclosures of electrical equipment on the basis of the degree of protection provided ...

Page 13

IEC 60529 Classification Designations — Second and Third Characteristic Numerals Second Characteristic Numeral Corresponds to protection of equipment against penetration of water with harmful effects. 0 Non-protected 1 Protected against vertical dripping water (condensation). Protected against dripping 2 water at ...

Page 14

Technical Information: Kilowatt Motor Ratings Technical Information: Kilowatt Motor Ratings The tables below provide the average full-load currents of squirrel cage motors in accordance with IEC conventions. These are given only as a guide — they may vary depending on ...

Page 15

Technical Information: Horsepower Motor Ratings The table below provides the average full-load currents of squirrel cage motors based on NEC (National Electrical Code) Tables 430-148, 149, and 150. These values are given only as a guide — they may vary ...

Page 16

... Definitions of Utilization Categories Definitions of Utilization Categories IEC contactors should be selected according to the utilization category which is a combination of application and duty cycle rates defined by the following: • The type of application (inductive motor loads or resistive loads) • The conditions under which making or breaking current takes place (motor starting or running, reversing, plugging or jogging, locked rotor or stalled motor) • ...

Page 17

... The following tables show the results of tests performed according to standard utilization categories conforming to IEC 60947 based on rated operational current (Ie) and rated operational voltage (Ve). Contactors AC Supply Utilization Typical Applications Category Resistors, non-inductive AC-1 or slightly inductive loads Slip ring motors: AC-2 starting, breaking ...

Page 18

Contactor Selection for Utilization Category AC-3 Contactor Selection for Utilization Category AC-3 How to Use the Electrical Life Curves The contactor electrical life curves on the following pages may be used to estimate the number of make and break operations ...

Page 19

In many applications there is a mixture of AC3 and AC4 duty. For these applications the electrical life of a particular contactor can be estimated by using the following formula: Where Estimated electrical life for mixed duty application ...

Page 20

... V 400 V 440 V NOTE: The dotted lines relate to LC1D38 contactors only. Operational power in kW-50 Hz. Example: Asynchronous motor with P = 5.5 kW – 400 V – – Use in Category AC-3 (Ve = 660/690 Vac) Control of 3-phase asynchronous squirrel cage motors with breaking while 10 running ...

Page 21

Use in Category AC-3 (Ve Control of 3-phase asynchronous squirrel cage motors with 10 8 breaking while 6 running. 4 The current broken (Ic) in category AC equal to the rated 1.5 operational current 1 (Ie) of the ...

Page 22

Contactor Selection for Utilization Category AC-1 Contactor Selection for Utilization Category AC-1 Maximum Operational Current (Open-mounted Device) Contactor Size Maximum operating rate operating cycles/hour Cabling to IEC 60947-1 Operational current AC-1 according to the ambient temperature to ...

Page 23

... Use motor full-load 0.6 current on horizontal 0.4 axis for selection purposes. 0.2 0.1 20 NOTE: The dotted lines relate to LC1F225 contactors only. Example 220 V – 500 A ( 01/04 Contactor Selection for Utilization Category AC-1 LC1 LC1 LC1 LC1 LC1 LC1 LC1 LP1 ...

Page 24

Contactor Selection for Utilization Categories AC-2 and AC-4 Contactor Selection for Utilization Categories AC-2 and AC-4 Utilization category AC-2 is for breaking the starting current of slip-ring motors, while utilization category AC-4 is for breaking the starting current of squirrel-cage ...

Page 25

Maximum Breaking Current for Categories AC-2 and AC-4 LC1 LP1 Contactor Size D50 In category AC-4 (Ie maximum) A 300 – Ve 440 Vac Ie maximum broken = motor – 440 Vac Ve 690 Vac A 170 ...

Page 26

... NOTE: The dotted lines relate to LC1K12 and LP1K12 contactors only. Example: Asynchronous motor with P = 5.5 kW – 400 V – Use in Category AC-4 (440 Vac < Ve Control of 3-phase asynchronous squirrel cage motors with breaking while motor stalled ...

Page 27

Use in Categories AC-2 or AC-4 (Ve 1 Control of 3-phase 0.8 asynchronous squirrel 0.6 cage (AC-4) or slip- 0.4 ring (AC-2) motors with breaking while motor stalled. 0.2 The current broken 0.1 (Ic) in category AC-4 0.08 is equal ...

Page 28

... Vdc 300 Vdc 460 Vdc 900 Vdc 1200 Vdc 1500 Vdc f For rated operational currents of contactors LC1 and LP1K, please consult your Local Square D Field Sales Office. Continued on next page. 28 © 2001-2004 Schneider Electric All Rights Reserved L 1 ms, ambient 55 °C [131 °F] ...

Page 29

... Vdc 2 – 1200 Vdc 3 – 1500 Vdc 4 – f For rated operational currents of contactors LC1 and LP1K, please consult your Local Square D Field Sales Office. 01/04 Contactor Selection for Utilization Categories DC-1 to DC-5 55 °C [131 °F] LC1 LC1 LC1 LC1 LC1 D115 ...

Page 30

Contactor Selection for Utilization Categories DC-1 to DC-5 Use in Category DC-1 to DC-5 The criteria for contactor selection are: • The rated operational current Ie. • The rated operational voltage Ve (see page 31). • The utilization category and ...

Page 31

... On D-line contactors, you can use the AC inductive/resistive rating as long as the voltage does not exceed 75 volts per pole. On F-line contactors, the voltage must not exceed 125 volts per pole. However, by wiring the contacts in series, you can multiply the number of poles in series by the maximum voltage allowed per pole ...

Page 32

Voltage Code Tables Voltage Code Table Voltage Code Tables _ See notes pertaining to each product line at the end of this table. K-line LC1K LC7K LC2K Voltage Frequency LC8K Notes Note K4 K1 Low - ...

Page 33

Voltage Code Tables (Continued) _ See notes pertaining to each product line at the end of this table. K-line LC1K LC7K LC2K Voltage Frequency LC8K Notes Note K4 K1, K2 K2, K3 50/ 100 50/60 ...

Page 34

Voltage Code Tables Voltage Code Tables (Continued) _ See notes pertaining to each product line at the end of this table. K-line LC1K LC7K LC2K Voltage Frequency LC8K Notes Note K4 K1, K2 K2, K3 50/ ...

Page 35

... LC2K the operating range is 0.80 - 1.15 of nominal. D line: D1 For operating ranges refer to technical data section of the D-line contactors. Ranges vary as a function of the current rating of the contactor and type of supply (AC/DC) D2 LC1-D150 Contactors utilize dual frequency 50/60 Hz. coils only. Single frequency coils are not available. ...

Page 36

Definitions and Comments Definitions and Comments The low oxygen atmosphere at high altitudes reduces the dielectric strength of the air and hence the rated operational voltage of the contactor. It also reduces the cooling effect of the air and hence ...

Page 37

... Catalog 04 TeSys™ K-Line Mini-Contactors, Overload Relays, and Accessories File 8502 K-Line CONTENTS Description General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Mini-contactors Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 K-line Voltage Code Table Auxiliary Contacts and Timers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Dimensions and Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 Schematics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59 Overload Relays Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63 Dimensions, Mounting, and Schematics Low-consumption Mini-contactors Characteristics ...

Page 38

... Spring terminals for extreme-vibration applications. • Control circuit flexibility All versions of the K-line mini-contactors are available with an AC, DC, or low-consumption DC operating coil. The low-consumption DC coil operating device can be energized by a low level DC signal from a computer or PLC and includes built-in transient suppression and LED “On” indicator. ...

Page 39

... Safe circuit separation Cabling Screw-clamp terminals Slip-on connectors Solder pins for printed circuit board Tightening torque Terminal referencing f Safety extra low voltage. 01/04 Characteristics of Type LC•K and LP•K Contactors Conforming to IEC 60947 V 690 Conforming to VDE 0110 750 Conforming to BS 5424 20-040 V 690 Conforming to CSA 22-2 No ...

Page 40

... Characteristics of Type LC•K and LP•K Contactors Pole Characteristics Conventional thermal current (Ith) For ambient temperature Rated operational frequency Frequency limits of the operational current Rated operational voltage (Ve) Rated making capacity Rated breaking capacity Permissible short-time rating Short-circuit protection Average impedance/pole Utilization in category AC-1: ...

Page 41

... For mains supplies with a high level of interference (voltage surge > 800 V), use a suppressor module LA4KE1FC (50 to 129 LAFKE1UG (130 to 250 V); see page 56. LC1K16: 0.85 to 1.15 Vc. q 01/04 Characteristics of Type LC•K and LP•K Contactors LC1 LC2 12 to 690 Vac f For operation q 0.8 to 1.15 Vc For drop-out 0 ...

Page 42

... Characteristics of Type LC•K and LP•K Contactors Auxiliary Contact Characteristics and Instantaneous Contact Blocks Number of contacts Rated operational voltage (Ve) Rated insulation voltage (Vi) Conventional thermal current (lth) Frequency of operational current Minimum switching capacity Short-circuit protection Rated making capacity Overload current Insulation resistance Non-overlap distance ...

Page 43

... Selection of Contactors for Motor Control General-Purpose Contactors for AC Control Circuits The table below shows general-purpose contactors. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. For information on add-on auxiliary contact blocks and accessories, see page 54 to 58. ...

Page 44

... The tables below show the kilowatt ratings (for international applications) and horsepower ratings (for North American applications) of contactors for use in sensitive environments. They are recommended for use in areas sensitive to noise, high interference mains supplies, and so forth. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to- tighten” ...

Page 45

... Three-Pole Contactors for DC Control Circuits The table below shows the kilowatt ratings (for international applications) and horsepower ratings (for North American applications) for three-pole contactors for DC control circuits. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to- tighten” ...

Page 46

... The tables below show general-purpose and sensitive-environment three- and four-pole contactors for AC control circuits. (The sensitive-environment contactors are recommended for use in areas sensitive to noise, high interference mains supplies, and so forth.) The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. In addition, the sensitive-environment contactors include a coil with a built-in rectifier and suppressor ...

Page 47

... Three- and Four-Pole Contactors for DC Control Circuits The table below shows three- and four-pole contactors for DC control circuits. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to- tighten” position. For information on add-on auxiliary contact blocks and accessories, see page 54 to 58. ...

Page 48

... Three-Pole Reversing Contactors for AC Control Circuits The table below shows three-pole reversing contactors with integrated mechanical interlock. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. Customer wiring is required to connect coil terminations to electrical interlock ...

Page 49

... A coil with incorporated rectifier and suppressor is standard. LC8K06105 The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. Customer wiring is required to connect coil terminations to electrical interlock; see page 60 (top row, center wiring diagram). ...

Page 50

... The table below show the kilowatt ratings (for international applications) and horsepower ratings (for North American applications) for three-pole reversing contactors with integrated mechanical interlock for DC control circuits. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. Customer wiring is required to connect coil terminations to electrical interlock ...

Page 51

... The contactors incorporate an integrated mechanical interlock. Both types of contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. In addition, the sensitive-environment contactors include a coil with a built-in rectifier and suppressor. Customer wiring is required to connect coil terminations to the electrical interlock ...

Page 52

... The table below shows general-purpose three-pole reversing and four-pole change over contactors for DC control circuits. The contactors incorporate an integrated mechanical interlock. The contactors mount DIN rails or with screws. The wire termination screws are in the open, “ready-to-tighten” position. Customer wiring is required to connect coil terminations to the electrical interlock ...

Page 53

K-line Voltage Code (Continued) K-line (see notes at end of table) LC1K Voltage Frequency LC2K Notes K1, K2 110/127 40-400 - 50/60 FE7 115 50 - 40-400 - 50/ 120 40-400 - DC - Low ...

Page 54

Selection of Auxiliary Contacts and Timers Selection of Auxiliary Contacts and Timers XX LC1/LC7/LP1K LC1/LC7/LP1K LC1/LC7/LP1K 54 © 2001-2004 Schneider Electric All Rights Reserved LA1KN LA1KN M LA1KN LA2KT2 LA1 KN P 01/04 ...

Page 55

... EN 50012 q See pages 59 and 60 for actual terminal markings. q Electronic Time-Delay Auxiliary Contact Blocks for Type LC•K and LP•K Contactors – Relay output, with common point changeover contact 240 Vac maximum. – Control voltage: 0.85 to 1.1 Vc. – Maximum switching capacity: 250 VA or 150 W. ...

Page 56

... Selection of Accessories Selection of Accessories Coil Suppressor Modules With an LED Indicator for Type LC•K and LP•K Contactors Mounting and connection Clip-on mounting on the front of LC1 and LP1 contactors. No tools required. LA4K Protection by limitation of the transient voltage maximum. Maximum reduction of transient voltage peaks. ...

Page 57

... Dimensions and Mounting of Type LC\bK and LP\bK Contactors XXX Contactors LC1K, LC7K, LP1K On panel LA1 1.22 2.24 On one asymmetrical rail DZ5MB with clip-on mounting plate LA9D973 2.24 0.83 On printed circuit board 8. 0.34 10xØ1 1.78 Electronic time-delay auxiliary contact blocks LA2KT 34 1 ...

Page 58

... Reversing contactors LC2K, LC8K, LP2K On panel LA1K 4 mm (#6) screws 1.22 2.24 On one asymmetrical rail DZ5MB with 2 clip-on mounting plates LA9D973 mounting plates DX1AP25 LA9D973 = 57 21 2.24 0.83 On printed circuit board for reversing contactors or 2 contactors mounted side by side 8. 8.65 0.34 0. 20xØ1 ...

Page 59

... For 3-pole contactors 2 N. N.C. LA1KN02M LA1KN11M For 4-pole contactors 1 N. N.C. LA1KN11P Electronic time delay auxiliary contact blocks LA2KT For contactors LC K and C/O 01/04 Integrated-coil suppression device LC7K Integrated-coil suppression device LC7K 1 N. N.C. LA1KN11 LA1KN117 2 N. N.C. ...

Page 60

... Schematics Type LC•K and LP•K Reversing Contactors and Accessories 3-pole reversing contactors LC2K, LC8K, LP2K With screw clamp terminals N.O. With Slip-on connectors or solder pins (printed circuit board N.O. 4-pole reversing contactors LC2K, LC8K, LP2K With screw clamp terminals 4 P Instantaneous auxiliary contact blocks LA1K For contactors LC K and LP2K 2 N ...

Page 61

... A2 connected to overload relay terminal 96 on all products, - contactor terminal 14 connected to overload relay terminal 95 on products with N.O. When using N.C contactors, or the N.O. auxiliary contact marked 13-14 voltage other than the coil voltage, break off the link marked 14. (See page 64 for additional information ...

Page 62

Characteristics of Type LR•K Overload Relays Electrical Characteristics of the Power Circuit Rated operational voltage (Ve) Rated insulation voltage (Vi) Rated impulse withstand voltage (Vimp) Frequency limits of the operational current Power dissipated per pole Short-circuit protection and coordination Operating ...

Page 63

... These overload relays are designed for the protection of motors. They are ambient-compensated and phase-failure sensitive. They may be reset either manually or automatically. For direct mounting, the relays are placed under the contactors with screw clamp terminals only (pre-wired terminals; see page 64). For separate mounting, use terminal block LA7K0064 (see below). ...

Page 64

Dimensions, Mounting, and Schematics for Type LR•K Overload Relays Dimensions, Mounting, and Schematics for Type LR\bK Overload Relays Protection Components LR2K Direct mounting beneath the contactor 8 = 0.31 65 2.56 LR2K A H Reset/stop 64 © 2001-2004 Schneider Electric ...

Page 65

... Cabling Screw clamp terminals Slip-on connectors Solder pins for printed circuit board Tightening torque Terminal referencing q Safe extra low voltage. 01/04 Characteristics of Type LP•K Low-consumption Contactors Conforming to IEC 60947 V 690 Conforming to VDE 0110 750 Conforming to BS 5424 20-040 V 690 Conforming to CSA 22.2 No. 14, UL 508 V ...

Page 66

... Characteristics of Type LP•K Low-consumption Contactors Pole Characteristics Conventional rated thermal current (Ith) Rated operational frequency Frequency limits of the operational current Rated operational voltage (Ve) Rated making capacity Rated breaking capacity Permissible short time rating Short-circuit protection Average impedance per pole Utilization in category AC-1 ...

Page 67

... Operating time at 20 °C (68 °F) and at Vc Maximum immunity to micro breaks Maximum operating rate Mechanical durability millions of operating cycles Wide range DC coil Auxiliary Contact Characteristics of Contactors and Instantaneous Contact Blocks Number of contacts Rated operational voltage (Ve) Rated insulation voltage (Vi) Conventional rated thermal current (lth) For ambient temperature ...

Page 68

... Standard control circuit voltages (variable delivery times, please consult your Local Square D Field Sales Office). f Use voltage codes on page 52 “Voltage Code Table” to complete catalog number. p LP4K06105 68 © 2001-2004 Schneider Electric All Rights Reserved Kilowatt Ratings for International Applications Standard power ratings of 3-phase ...

Page 69

... Standard control circuit voltages (variable delivery times, please consult your Local Square D Field Sales Office.). f Pre-wired power circuit connections are standard on screw clamp versions. q Use voltage codes on page 52 “Voltage Code Table” to complete catalog number. p LP5K06105 01/04 Selection of Low-consumption Reversing Contactors for Motor Control ...

Page 70

... Category AC-1 LP4K090047 Maximum current at 50 °C (122 ° Standard control circuit voltages (variable delivery times, please consult your Local Square D Field Sales Office.). f Use voltage codes on page 52 “Voltage Code Table” to complete catalog number © 2001-2004 Schneider Electric All Rights Reserved ...

Page 71

... Maximum current at 50 °C (122 ° Standard control circuit voltages (variable delivery times, please consult your Local Square D Field Sales Office.). c WARNING: These reversing contactors are pre-wired for reverse motor operation p Use voltage codes on page 52 “Voltage Code Table” to complete catalog number. 01/04 ...

Page 72

... Selection of Auxiliary Contacts and Accessories for Low-consumption Contactors Selection of Auxiliary Contacts and Accessories for Low-consumption Contactors Instantaneous Auxiliary Contact Blocks (clip-on front mounting, 1 block per contactor) Type of Connection Screw clamp LA1KN Slip- 0.25 in 0.11 in. Spring terminals With terminal referencing conforming to EN 50012 Screw clamp k See pages 75 and 76 for actual markings ...

Page 73

... Dimensions and Mounting of Low-consumption Contactorsxxxxx Contactors LP4K On panel LA1 1.22 2.24 On one asymmetrical rail DZ5MB with clip-on mounting plate LA9D973 2.24 0.83 On printed circuit board 8. 0.34 10xØ1 1.78 Electronic time-delay auxiliary contact blocks LA2KT 34 1.34 01/04 Dimensions and Mounting of Low-consumption Contactors On mounting rail AM1DP200 or AM1DE200 1 ...

Page 74

... Dimensions and Mounting of Low-consumption Reversing Contactors Reversing contactors LP5K On panel LA1K 4 mm (#6) screws 1.22 2.24 On one asymmetrical rail DZ5MB with 2 clip-on mounting plates LA9D973 mounting plates DX1AP25 LA9D973 2.24 0.83 On printed circuit board for reversing contactors or 2 contactors mounted side by side 8. 8.65 0.34 0. 20xØ1 1.78 1 ...

Page 75

... Type LP\bK Schematics Type LP•K Three-Pole Low-Consumption Contactors, Reversing Contactors, and Accessories 3-pole contactors LP4K 3-pole + N.O. 3-pole reversing contactors LP5K With screw clamp terminals 3-pole + N.O. With Slip-on connectors or solder pins for printed circuit boards 3-pole + N.O. Instantaneous auxiliary contact blocks ...

Page 76

... Type LP•K Schematics Type LP•K Four-Pole Low-Consumption Contactors, Reversing Contactors, and Accessories 4-pole contactors LP4K 4-pole + N.O. 4-pole reversing contactors LP5K With screw clamp terminals Instantaneous auxiliary contact blocks LA1K 2 N.O. 2 N.C. LA1KN20 LA1KN02 LA1KN207 LA1KN027 Electronic Time-delay Auxiliary Contact Blocks ...

Page 77

... Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134 Plate-mounted Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Dimensions, Mounting, and Schematics 138 Wye-delta Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Plate-mounted Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144 Enclosed Contactors and Starters Wye-delta Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146 Horsepower Rated Devices for North American Applications 151 Enclosed Contactors and Starters Kilowatt Rated Devices for International Applications 159 Horsepower Rated Devices for North American Applications ...

Page 78

Schneider Electric All Rights Reserved 01/04 ...

Page 79

... General Information The D-line contactors and overload relays are the largest selling line of contactors and starters in the world. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry. Contactor Ratings • D-line contactors and overload relays are available in 11 contactor ratings for the USA market for inductive motor applications up to 150 full-load amps and resistive loads up to 200 A ...

Page 80

... Characteristics of Type LC•D and LP•D Contactors Characteristics of Type LC\bD and LP\bD Contactors Environment Type UL/CSA To IEC 60947-4-1, overvoltage Rated insulation voltage (Vi) category III, degree of pollution: 3 Conforming to UL, CSA Rated impulse withstand voltage Conforming to IEC 60947 (Vimp) Meets the essential requirements of the Conforming to standards LV & ...

Page 81

... Power dissipation per pole for the above operational currents AC-1 Protection provided for the cable c.s.a. indicated on page 86 and for cable connections the least favorable direction, without change of contact state (coil supplied at Ve). q 01/04 Characteristics of Type LC•D and LP•D Contactors LC1D32 V 690 V 1000 V 600 ...

Page 82

... Characteristics of Type LC•D and LP•D Contactors Control Circuit Characteristics Type Rated control circuit voltage (Vc coils Control voltage limits ( 55 °C [131 °F]) 50/60 Hz coils Average consumption at 20 °C (68 °F) and Heat dissipation 50/60 Hz Closing “C” c Operating time Opening “O” coil ...

Page 83

... The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. c The opening time “O” is measured from the moment the coil supply is switched off to the moment the mains poles separate. q 01/04 Characteristics of Type LC•D and LP•D Contactors LC1D40 LC1D50 ...

Page 84

... Characteristics of Type LC•D and LP•D Contactors DC Control Circuit Characteristics Type of contactor Rated control circuit voltage (Uc) dc Conforming to IEC 60947-1 Rated insulation voltage Conforming to UL, CSA Operational Control voltage limits Drop-out Average consumption at 20 °C (68 ° and at Uc Closing Opening Average operating time at Uc (1) Note: The arcing time depends on the circuit switched by the poles ...

Page 85

... Characteristics of Type LC•D and LP•D Contactors 60 °C (140 ° 500 ms 100 ms 0. times the power broken 24 48 115 230 400 440 60 120 280 560 960 ...

Page 86

... Characteristics of Type LC•D and LP•D Contactors Power Circuit Connections Type Stranded cable without cable end Stranded cable with cable end Cabling (for screw clamp terminals) Solid cable without cable end Phillips head type Screwdriver Ø Hexagon spanner Tightening torque Bar c.s.a. ...

Page 87

... Screwdriver Ø Tightening torque Connection by bus bar or ring-tongue terminals Lug external Ø Screw Ø Phillips head type Screwdriver Ø Tightening torque 01/04 Characteristics of Type LC•D and LP•D Contactors LC1D65 LC1D80 LP1D65 LP1D80 Connector type Box lug terminals 1 conductor AWG 10-3 10-2 ...

Page 88

... Selection of Contactors for Motor Control The tables below show the kilowatt ratings (for international applications) and horsepower ratings (for North American applications) of contactors for motor control. AC and DC Control Circuit — 3-pole Contactors with Touch-safe Terminals for Power Cabling (AC-3 category) Maximum horsepower ratings 1-phase 50/60 Hz ...

Page 89

... The tables below show the kilowatt ratings (for international applications) and horsepower ratings (for North American applications) of contactors for motor control. LC1D123 AC and DC Control Circuit — 3-pole Contactors for Spring Terminal Connections (AC-3 category) Maximum horsepower ratings 1-phase 50/60 Hz 3-phase 50/60 Hz ...

Page 90

... Devices are UL Listed at the same HP ratings as 32 and 80 amp devices, respectively and DC Control Circuit — 3-pole Contactors for Connection with Slip-on Connectors For contactors LC1D09 and LC1D12 only, replace the last digit in the catalog numbers shown in the table above (“6”) with a 9. For example, LC1D096 slip-on connectors: UL Recognized ...

Page 91

... Selection of Contactors for Resistive Loads (AC-1) and Inductive Loads (AC-3) Selection of Contactors for Resistive Loads AC and DC Control Circuit — 4-Pole Screw Terminal Connections (AC-1 Category) Maximum Current Utilization Categories AC LC1DT20 125 200 AC and DC Control Circuit — 4-Pole Spring Terminal Connections (AC-1 Category) ...

Page 92

... AC and DC Control Circuit — Contactors for Connection with Slip-on Connectors (3-pole only) AC-1 category For contactors LC1D09 and LC1D12 only, replace the last digit in the catalog numbers shown in the table above (“6”) with a 9. For example, LC1D096 slip-on connectors: UL Recognized ...

Page 93

... Use voltage codes on page 115 “Voltage Code Table” to complete catalog number. p For reversing contactors with electrical interlocking pre-wired at the factory, add suffix V to the catalog number reflected above. Example: LC2D09 k Devices are UL Listed at the same HP ratings as 32 and 80 amp devices, respectively. ...

Page 94

... LADN or LAD8N type auxiliary contact block. Use voltage codes on page 115 “Voltage Code Table” to complete catalog number. p For reversing contactors with electrical interlocking pre-wired at the factory, add suffix V to the catalog number reflected above. Example: LC2D09 t LC2D38 is UL Listed at the same HP rating as the 32 amp device. ...

Page 95

... AC and DC Control Circuit — 3-pole Reversing Contactors for Connection with Slip-on Connectors (AC-3 category) For contactors LC2D09 and LC2D12 only, replace the last digit in the catalog numbers shown in the table above (“6”) with a 9. For example, LC2D096 slip-on connectors: UL Recognized ...

Page 96

... Selection of Changeover Contactors for Resistive Loads (AC-1) and Inductive Loads (AC-3) Selection of Changeover Contactors for Resistive Loads The contactors have pre-wired power connections. Order accessories separately. For information on auxiliary contact blocks and modules, see pages 106 to 107. AC and DC Control Circuit — 4-pole ...

Page 97

... Selection of Changeover Contactors for Resistive Loads (AC-1) and Inductive Loads (AC-3) AC and DC Control Circuit— 4-pole Changeover Contactors with Ring-tongue Terminal or Bus Bar Power Connection (AC-1 category) Maximum Current Utilization Categories AC 125 200 For LC2D12 and LC2D25: clip-on mounting DIN rail AM1DP or screw mounting. ...

Page 98

... N. N.C. main pole contactor (1) To order the 2 contactors: see pages 88, 89 and 90. (2) Mechanical interlock kit includes line and load side power connectors, mechanical interlock, control circuit interlock (LAD9R1V only), and clip. LAD9R1 Interlock only -- LAD9V2 (includes retaining clip) ...

Page 99

... Order two contact bocks LADN 1 to obtain electrical interlocking between the contactors, see page 106. (4) To build a reversing contactor with spring terminal connections, the following components must be ordered in addition to the two contactors mechanical interlock LAD9V2 downstream power connection kit LAD9V9 LA9D8070 ...

Page 100

... Characteristics of Auxiliary Contacts, Timers, and Accessories Characteristics of Auxiliary Contact Blocks, Timers, and Accessories Auxiliary Contact Blocks without Dust and Damp Protected Contacts for Contactors Environment Contact block type Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 Degree of protection Conforming to VDE 0106 ...

Page 101

... Auxiliary Contact Blocks with Dust and Damp Protected Contacts for Contactors Operational Power of Contacts (conforming to IEC 60947-5-1) AC supply, categories AC-14 and AC-15 Electrical durability (valid up to 3600 operating cycles/hour inductive load such as the coil of an electromagnet: making power (cos times the power broken (cos ...

Page 102

... Characteristics of Auxiliary Contacts, Timers, and Accessories Auxiliary Contact Blocks with Dust and Damp Protected Contacts for Contactors Environment Contact block type Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 Degree of protection Conforming to VDE 0106 Ambient air temperature Storage and operation Phillips N° ...

Page 103

... Interface Modules for Contactors Environment Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 Degree of protection Conforming to VDE 0106 Storage Ambient air temperature Operation around the device Permissible for operation at Uc Other Characteristics Module type Rated insulation voltage Conforming to IEC 60947-1 ...

Page 104

... Characteristics of Auxiliary Contacts, Timers, and Accessories Electronic Serial Timer Modules for Contactors Environment Module type Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 Degree of protection Conforming to VDE 0106 Storage Ambient air temperature Operation around the device For operation at Uc Rated insulation voltage (Ui) Conforming to IEC 60947-1 Phillips N° ...

Page 105

... Control Modules, Coil Suppressor Modules and Mechanical Latch Blocks for Contactors Environment Conforming to standards Product certifications Protective treatment Conforming to IEC 60068 Degree of protection Conforming to VDE 0106 Storage Ambient air temperature Operation around the device Permissible for operation at Uc “Auto - Man - Stop” Control Modules Recommendation The Auto - Man selector switch must only be operated with the Start - Stop (“ ...

Page 106

... Selection of Auxiliary Contact Blocks Selection of Auxiliary Contact Blocks aaa LC1D LAD-8N The LA6DK cannot be utilized with LC1D09 through D38 TeSys contactors. q 106 © 2001-2004 Schneider Electric All Rights Reserved LAD-N10, N01 (for LC1-D40 through D95 only) LAD-N LAD-N LAD-C LAD-T LAD-S2 ...

Page 107

... Side 2 For terminal referencing conforming to standard EN 50012 Front contactors & contactors 20 to 60A 2 Front contactors 80 to 200A 4 With dust and damp protected terminals, for use in particularly harsh industrial environments 2 Front 4 For LC1D40 through LC1D95 only. f Device with 4 shield bonding terminals. q Mount on left side only of LCkD09 through D38 with AC coils. Not allowed on LCkD09 through D38 with DC coils. ...

Page 108

... LADS2: with switching time ± between opening of the N.C. contact and closing of the N.O. contact. Clip-on Mounting Front LADTk Also fit pre-TeSys Contactors. f Time delay auxiliary contact blocks for connection by ring-tongue connectors Add the digit 6 to the end of the references selected above. Example: LADT0 becomes LADT06. ...

Page 109

... The Low Voltage Ride Through Module can be used with all TeSys control relays with 24 VAC, 120 VAC or 208 VAC dual frequency coils. ** LAD4BB must be used when the Low Voltage Ride Through Module is being used with contactors 32 A and less, and TeSys CAD Series of Control Relays. Specifications Continuous operating voltage range and line frequency Max ...

Page 110

Selection of Electronic Timers and Interface Modules LA4-DT LA4-DF LC1-D09 to D38 (AC only) LC1DT20 to DT40 (AC only) 110 © 2001-2004 Schneider Electric All Rights Reserved Selection of Electronic Timers and Interface Modules LA4-DL LAD-4BB ** **See Cabling Accessories ...

Page 111

... On-delay Type Operational Voltage 250 V LC1 D09 to D38 (3P) and DT20 to DT60 (4P) Interface Modules 3-pole contactors LC1D40 to D150 and 4-pole contactors LC1D65 to D115: mounted directly across terminals A1 and A2 of contactor ( k screw mounting). Relay Interface Operational Voltage 250 V – LC1D09 to D150 (3P) and DT20 to DT60 (4P) Relay Interface with Manual Override Switch (output forced “ ...

Page 112

... For satisfactory protection, a suppressor module must be installed across the coil of each contactor. (2) From LC1D09 to D38 and LC1DT20 to DT40, dc and low consumption 3-pole contactors are fitted with built-in suppression as standard. (3) Clipping-on makes the electrical connection. The overall size of the contactor remains unchanged. ...

Page 113

... Control circuit take-off from main pole Spreaders for increasing the pole pitch D115, D150 LA9D11560 • (1) For 3-pole contactors: 1 set of 6 covers, for 4-pole contactors: 1 set of 8 covers. (2) Separate connecting bar for connecting 2 poles in parallel. Dimensions: pages 122, 123 LA9D11570 • ...

Page 114

... System requirement: 486 processor or better; Windows 95 4.0 or better. q Mounting Accessories XBY1U Mounting plate Set of shims (1) These legends are for sticking onto the safety cover of the contactors or add-on block, if fitted. 114 © 2001-2004 Schneider Electric All Rights Reserved For Use on Contactors 3-pole LC1D115 ...

Page 115

D-line Voltage Code Table D-line Voltage Code D-line (see notes at end of table) LC1D09 - D38 Voltage Frequency LC2D09 - D38 Notes D1 Low Consump AL DC 50/ Low Consump JL ...

Page 116

... U7 U7 Notes For operating ranges refer to technical data section of the D-line contactors. Ranges vary as a function of the current rating of the U6 U6 contactor and type of supply (AC/DC LC1-D150 Contactors utilize dual frequency 50/60 Hz. coils only. Single frequency coils - - are not available. ...

Page 117

... The last two digits of the reference represent the voltage code. (2) Voltage for special coils installed in contactors with serial timer modules, with 24 V supply. 01/04 Average resistance at 20 °C ± 10% = 0.75) 70 VA, = 0.3) 50 Hz: 7 VA, 60 Hz: 7.5 VA. 60 °C / 140 °F): 50 Hz: 0.8 to 1.1 Uc, 60 Hz: 0.85 to 1.1 Uc. ...

Page 118

... Selection of AC Coils AC Coils for 3 or 4-pole Contactors LC1D40, D50, D65, D80, D95 Specifications Control circuit voltage Uc V Average consumption at 20 °C (68 °F): - inrush (cos - sealed (cos Operating range ( LX1D6 k 110 115 120 127 208 220 220/230 230 240 256 277 ...

Page 119

... Selection of AC Coils AC Coils for 3 or 4-pole Contactors LC1D115 Control circuit voltage Uc V Specifications Average consumption at 20 °C (68 °F): - inrush (cos - sealed (cos Operating range ( LX1D8 kk 110 115 120 127 208 220 230 240 277 380 400 415 440 480 500 ...

Page 120

... Selection of DC Coils Selection of DC Coils DC Coils for 3-pole Contactors LC1D40 to D65 or 4-pole Contactors LP1D65 Control circuit voltage Uc V Specifications Average consumption Operating range: 0.85 to 1.1 Uc LX4D6 110 125 220 250 440 For 3-pole contactors LC1D80 or 4-pole contactors LP1D80 Specifications Average consumption ...

Page 121

... The last two characters of the reference represent the voltage code. Wide Range DC Coils for 3-pole Contactors LC1D40 to D65 or 4-pole Contactors LP1 to D65 Control circuit voltage Uc V Specifications Average consumption Operating range: 0.75 to 1.2 Uc. Coils with “TH” treatment as standard. ...

Page 122

... Dimensions for Type LC1D Contactors Dimensions for Type LC1D Contactors D-Line Contactors AC Control Circuits X LC1D09 to D18 (3-pole) Minimum electrical clearance 0. LC1 D09 to D18 b without add-on blocks 3.03 (77) b1 with LAD4BB 3.70 (94) with LA4D 2 4.33 (110) (1) with LA4DF, DT 4.68 (119) (1) with LA4DR, DW ...

Page 123

... D-Line Contactors DC Control Circuit or Low Consumption LC1D09 to D18 (3-pole) Minimum electrical clearance 0. LC1 b c without cover or add-on blocks with cover, without add-on blocks c1 with LADN or C (two or four contacts) c2 with LA6DK10 c3 with LADT with LADT and sealing cover LC1DT20 to DT60 (4-pole) Minimum electrical clearance 0 ...

Page 124

... Mounting Information for Type LC1D and LP1D Contactors Mounting Information for Type LC1D and LP1D Contactors xx On mounting rail AM1DP200, DR200 or AM1DE200 (width 35 mm) LC1D09 to D38, DT20 to DT60 c LC1 D09 to D18 D25 to D38 b 3.03 (77) 3.36 (85) c (AM1DP200 or DR200) (1) 3.46 (88) 3.70 (94) c (AM1DE200) (1) 3 ...

Page 125

... LC1D115, D150 Panel mounted c Selection: pages 88 Characteristics: pages Units with DC coils have round mounting holes ONLY and are spaced at 70 mm. q 01/04 Mounting Information for Type LC1D and LP1D Contactors Control circuit: LC1 c with cover 4-pole contactors LC1 c ...

Page 126

... Schematics for Type LC1D Contactors Schematics for Type LC1D Contactors 3-Pole Contactors LC1D09 to D150 4-Pole Contactors LC1 and LP1 LC1 and LP1 D12004 to D80004 D12008 to D25008 LC1D115004 Front Mounting Add-on Contact Blocks Instantaneous Auxiliary Contacts One N.O. LADN10 (1) One N.C. LADN01 (1) Two N ...

Page 127

... Two N.C. LAD8N02 (1) Auto-Man-Stop modules LA4DMk (1) PLC (1) Auto/Man I/O K Relay interface with override switch LA4DL K K Schematics for Type LC1D Contactors Two N.O. protected (24- one N.O. + one N.C. standard LA1DZ31 (1) PLC Solid state LA4DWB K © 2001-2004 Schneider Electric All Rights Reserved 127 ...

Page 128

... Dimensions for Type LC2D Contactors Dimensions for Type LC2D Contactors LC2D09 to D38 2 x LC1D09 to D38 2xM0.16 2xM4 LC2 LC1 (1) D09 to D18 ac 3.54 (90) 3.03 (77) 3.38 (86) D093 to D183 ac 3.54 (90) 3.89 (99) 3.38 (86) D09 to D18 dc 3.54 (90) 3.03 (77) 3.74 (95) D093 to D183 dc 3.54 (90) 3.89 (99) 3.74 (95) D12004 – ...

Page 129

... Low speed - High speed cabling kit LAD- LS/HS Low speed 01/04 Reversing contactors for motor control with integral electrical interlocking (LAD9R1V) Changeover contactor pairs, horizontally mounted LC2DT20 to DT60 02 Mechanical interlock without integral electrical contacts LA9D – KM2 – KM1 – KM1 – ...

Page 130

... Impulse withstand voltage Conforming to IEC 60801-5 Auxiliary Contact Characteristics Conventional rated thermal current ac supply Maximum consumption of operating coils of controlled contactors (Occasional operating dc supply cycles of contact 95-96) Short-circuit protection Class CC fuse. Max. rating or by GB2 circuit-breaker Connection to screw clamp terminals Flexible cable with cable end ...

Page 131

Electrical Characteristics of Power Circuit Relay type Tripping class To UL 508, IEC 60947-4-1 Conforming to IEC 60947-4-1 Rated insulation voltage (Ui) Conforming to UL, CSA Rated impulse withstand voltage (Uimp) Frequency limits Of the operational current Setting range Depending ...

Page 132

... LR9D 3-pole Solid-state Overload Relays Description LR9D electronic thermal overload relays are designed for use with contactors LC1D115 and D150. In addition to the protection provided by model d thermal overload relays, (see page 130), they offer the following special features: k Protection against phase imbalance. ...

Page 133

Electrical Characteristics of Power Circuit Relay Type Tripping Class Rated Insulation Voltage (Ui) Rated Impulse Withstand Voltage (Uimp) Frequency Limits Setting Range Power Circuit Connections Operating Specifications Temperature Compensation Tripping Threshold Sensitivity to Phase Failure Alarm Circuit Specifications Rated Supply ...

Page 134

... LRD12 becomes LRD3312A66. Order an LA7D3064 terminal block separately; see page 137. (1) These are special separate mounted versions of the LRD43 overload relays for the LC1D115 and D150 contactors. Part number includes overload relay, terminal block and 6 connectors (unit is not UL/CSA approved). (2) When used with D25-D38 contactors, order spacer clip (part number W816366180111). See page 137. ...

Page 135

... Power terminals can be protected against direct finger contact by the addition of shrouds and/or insulated terminal blocks ordered separately (see page 113). (2) For use with D25-D38 contactors, order spacer clip (part number W816366180111). See page 137. (3) These overloads are available without single phase sensitivity. To order, change the LRD prefix to LR3D and add A1 to the end of the number. ...

Page 136

Selection of Overload Relay Accessories Selection of Overload Relay Accessories DX1-AP25 LA7-D03 DX1-AP26 LA7-D902 136 © 2001-2004 Schneider Electric All Rights Reserved LAD-7B10 LAD-703 LRD- LA7-D1064 LA7-D03 LR2-D15 LA7-D2064 LA7-D901 LR2-D25 LA7-D3064 LRD-3 LR2-D35 LAD-7305 LRD- LA7-D305 LRD-3 LRD- LRD-3 ...

Page 137

Accessories (to be ordered separately) Description Pre-wiring kit allowing direct connection of the N.C. contact of relay LRD01 LR3D01 to D35 to the contactor Separate Mount Kits Terminal blocks (1) for separate mounting rail ...

Page 138

... Characteristics: pages 130 - 133 Catalog Number: pages 134, 135 138 © 2001-2004 Schneider Electric All Rights Reserved LRD-013-353 Direct mounting beneath contactors with spring terminal connections LC1• D093 - 383 b 4.84 (123) c See pages 122, 123. AM1• ...

Page 139

Mounting Information for Bimetallic and Solid-state Overload Relays D-Line Thermal Overload Relays LRD-01-35 Independent mounting centers or on rail AM1DP200 or DE200 LAD-7B10 3.15 0.08 1. Remote tripping or electrical reset LAD-703 (1) 1.26 ...

Page 140

Mounting Information for Bimetallic and Solid-state Overload Relays D-Line Thermal Overload Relays LRD3••• and LR2D35•• Independent mounting centers or on rail AM1DP200 or DE200 LA7-D3064 4.76 d 2x¯0.18 121 2x¯4.5 AM1DP200 AM1DE200 d 0.08 (2) 0.37 (9.5) ...

Page 141

... With choke inductors connected, where necessary. Operational power at 50/ °C / 104 °F (1) 220 V 240 V kVAR 100 125 180 250 250 (1) Upper limit of temperature category conforming to IEC 70. 01/04 Capacitor-switching Contactors (International Applications Only) 55 °C / 131 °F (1) 400 V 600 V 220 V 440 V 690 V 240 V kVAR kVAR kVAR ...

Page 142

... Contactor Applications Specification Contactors fitted with a block of early make poles and damping resistors, limiting the value of the current on closing max. This current limitation increases the life of all the components of the installation, in particular that of the fuses and capacitors. The patented design of the add-on block (No. 90 119-20) ensures safety and long life of the installation. ...

Page 143

... DFK Number of conductors 1 2 Flexible cable with cable end AWG ( (2.5) 16 (1.5) 12 (4) 2 Solid cable without cable end AWG ( (4) 01/04 Capacitor-switching Contactors (International Applications Only) LC1DPK, DTK 1.77 45 LC1 See pages 124, 125 DPK See pages 124, 125 DTK LC1DWK 2.20 56 ...

Page 144

Plate-mounted Starters LC4D (International Applications Only) Plate-mounted Starters LC4D (International Applications Only) AC D.O.L. Starters, Plate Mounted, for Motor Control kW, (1), with Isolating Device, Pre-Assembled - References Utilization Category ac-3 Standard Power Ratings of 3-phase Motors ...

Page 145

D.O.L. Starters, Plate Mounted, for Motor Control kW, with Isolating Device, Pre-assembled - Dimensions, Schematics z Dimensions D.O.L. Starters Plate Mounted, Pre-assembled LC4D09 to D25A 4.69 119 3.94 0.17 100 4 2. ...

Page 146

... For other voltages, please consult your Regional Sales Office. (3) One auxiliary contact block type LADN can also be installed, see page 107. (4) These starters consist of contactors LC1D115 or D150 without connectors. 146 © 2001-2004 Schneider Electric All Rights Reserved Auxiliary Contacts Available on Each ...

Page 147

Wye-delta Starting Current Starting in direct delta connection 2 Starting in wye connection Torque 2,5 2 1 Starting in direct delta connection 2 Starting in ...

Page 148

AC Wye-delta Starter Kits (International Applications Only) AC Wye-delta Starter Kits (International Applications Only) a 148 © 2001-2004 Schneider Electric All Rights Reserved 01/04 ...

Page 149

... Separate Parts Description Mounting Kit comprising time delay contact block LADS2 (D09 to D80) (3) - power circuit connections (D09 to D80) - screws and clamps for attaching contactors to the plate (D40 to D80) - terminal block (D09 to D32) Equipment Mounting Plate (1) Protection must be provided by the addition of a thermal overload relay ordered separately. Select appropriate overload relay for setting at ...

Page 150

AC Wye-delta Starter Kits (International Applications Only) Wye-delta Starters - Dimensions, Schematics Dimensions for Wye-delta Starters On mounting rail AM1-DP, pre-assembled LC3-D090A to D320A KM2 6.30 c 160 6.89 LC3 D090A to D180A b 6.0 (153) c with LAD-S 5.4 ...

Page 151

... AC 3. Coil Frequency: Select dual frequency coils (50/60 Hz Hz. NOTE: For contactors, only dual frequency coils are available. For contactors, the 240 V coils are dual frequency only (50/60 Hz.). The 480 V to 600 V coils are 60 Hz. only. 4. Overload relay type: Select overload relay Trip Class 10 Trip Class 20. ...

Page 152

... No Transformer used 208 120 208 For use on Contactors LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 LC1D09–D32 LC1D09–D32 LC1D09–D32 LC1D12–D32 LC1D18–D32 LC1D25–D32 q LC1D40-80 c LC1D25– ...

Page 153

Enclosed IEC Combination Starters Horsepower Ratings for North American Applications of D-Line Products in Metal Enclosures with Fusible Disconnect Switch or Circuit Breaker IEC combination starters combine the requirements of motor overload and short circuit protection in one convenient compact ...

Page 154

... No Transformer used 208 120 208 For use on Contactors LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 q LC1D09–D32 LC1D09–D32 LC1D09–D32 LC1D09–D32 LC1D12–D32 LC1D18–D32 LC1D25–D32 LC1D25–D32 c LC1D25– ...

Page 155

Factory Modifications and Insta-Kit Selection Add the Factory Modification Code to the end of the catalog number created from pages 151 and 152. Only one operator scheme (factory modification code or field-installable Insta-Kit option) can be used. Only the combinations ...

Page 156

Dimensions for Enclosed Combination and Non-Combination IEC Starters Dimensions for Enclosed Combination and Non-Combination IEC Starters Combination Starter Dimensions with Rotary Disconnect Handle - Type 1 Knockout Schedule Knockout Conduit Size, in. (mm) A 0.50 (12.7) B 1.00 (25.4); 1.25 ...

Page 157

Schematics for Enclosed IEC Non-Combination Starters Non-Reversing, Non-Combination 3-Phase Starter Reset Reversing, Non-Combination 3-Phase Starter Reset 01/04 Schematics for Enclosed IEC Non-Combination Starters White Plug-in connector Yellow Brown Plug-in Connector Jumper Jumper Wire 4 ...

Page 158

Schematics for Enclosed IEC Combination Starters Schematics for Enclosed IEC Combination Starters Non-Reversing, Combination 3-Phase Starter Reversing, Combination 3-Phase Starter Reset 158 © 2001-2004 Schneider Electric All Rights Reserved White Plug-in connector Yellow Reset ...

Page 159

... International Enclosed Contactors LE1D (International Applications Only) D.O.L. AC Starters for Motor Control (1) 2 kW, without Isolator Device Applications Only Characteristics Conforming to standards Degree of protection to IEC 60529 IP 659: LE2K, IP 657: LEpD09 to D35 and IP 557: LEpD405 to D955 Ambient air temperature Operating positions Material Non-reversing Starters ...

Page 160

... Enclosed Contactors LE1D and LE2D D.O.L. AC Starters for Motor Control (1) 2 without Isolator Device, Non-reversing Description Standard versions comprise: • For non-reversing starters: • For reversing starters: — LE2K: — LE2D09 to D35: LE1D12••A04 — LE2D405 to D955: Forms (installed by Telemecanique) ...

Page 161

... International Enclosed Contactors with Fused Disconnect Switch LE4K/D (International Application Only) D.O.L. AC Starters for Motor Control (1), 2 with Isolator Device Applications Only Characteristics Conforming to standards Degree of protection to IEC 529 Ambient air temperature Operating positions Material Non-reversing Starters Standard Power Ratings of 3-phase Motors ...

Page 162

Enclosed Reversing Starters with Fused Disconnect Switch LE2, LE4 and LE8 International Enclosed Reversing Starters with Fused Disconnect Switch LE2D (Int’l App. Only) Applications Only D.O.L. AC Starters for Motor Control (1) 2 with Isolator Device Description ...

Page 163

Wye-delta Starters LE3D (International Applications Only) Wye-Delta Starters for Motor Control from kW, without Off-Load Isolator (1) - References Selection Standard Power Ratings of Squirrel Cage Motors Mains Voltage - Delta Connection (kW) 220 V Maximum operating ...

Page 164

Wye-delta Starters with Fused Disconnect Switch LE3D (International Applications Only) Wye-delta Starters with Fused Disconnect Switch LE3D (International Applications Only) International NOTE: Wiring methods differ from typical North American practice. Applications Only Contains UL Listed, CSA Certified, and CE marked ...

Page 165

... Mounting kit for head ZB5AL432 Operating Heads for Reset Pushbuttons Flush blue “R” (2) Mounting kit for head ZB5AA0 + ZBA639 ZB5AL432 Operating Heads for Selector Switches Description 3 position stay put 2 position stay put 3 position spring return to center Contact Blocks LAD9091 1 N.O. ...

Page 166

Spare Parts and Accessories (International Applications Only) Empty Enclosures for D.O.L. Starters Without Isolator Device For use with LE1D09, D12 DE1DS1A04 LE1D18 to D35 DE1DS1A05 DE1DS1 DE1DS1A13 166 © 2001-2004 Schneider Electric All Rights Reserved Push button operating head(s) or ...

Page 167

LE·D Dimensions (International Applications Only) Enclosed D-line Starters Without Fused Disconnect Switch LE1D09 and D12 0. Standard version 5.05 (128.5) Version A04 4.7 (120) Version A05 5.05 (128.5) Version A09 5.31 (135) ...

Page 168

LE·D Dimensions (International Applications Only) Enclosed D-line Starters With Fused Disconnect Switch LE4K06 and K09 LE8K06 and K09 1.15 x 0.21 0.74 0.78 3 6.88 4.72 175 120 c1 c1 LE4K LE8K Standard version 5.74 (146) 5.74 ...

Page 169

LE·K Dimensions (International Applications Only) Enclosed K-line Starters Without Fused Disconnect Switch LE3K065, K095 0.74 (19) 0.15 x 0.20 4.72 120 5.74 3.3 146 84 6.88 175 LE3D405 to D505 0. 8.85 225 14.4 367 LE3D805 ...

Page 170

LG1K and LG1D Dimensions (International Applications Only) Starters Without Isolator LE6D09 to D18 0. 7.32 186 c1 Standard version 6.90 (175.5) Version A04 6.57 (167) Version A05 6.90 (175.5) LE3D406 to D806 = 0.15 x ...

Page 171

LE1K and LE1D Wiring Diagrams (International Applications Only) LE1D09 to D955 – KM1 LE2K06, K09 – KM1 – KM2 LE2D09 to D955 – KM1 – KM2 01/04 LE1K and LE1D Wiring Diagrams (International Applications Only) LE1D09 to D955 A O ...

Page 172

LE2K and LE2D Wiring Diagrams (International Applications Only) LE2K and LE2D Wiring Diagrams (International Applications Only) LE6D09 to D18 – Q1 – KM2 – KM3 – KM1 LE3D326 t0 D806 – Q1 – KM3 – KM1 – KM2 172 © ...

Page 173

LE4K, LE4D, LE8K, and LE2D Dimensions (International Applications Only) LE3K065 and K095 – KM2 – KM3 – KM1 Recommended cabling for reversal of motor rotation (standard motor, viewed from shaft end). LE3D09 to D805 Ð KM2 Ð KM3 Ð KM1 ...

Page 174

LG1K, LG1D, LG7K, LG7D, and LG8K Dimensions (International Applications Only) LG1K, LG1D, LG7K, LG7D, and LG8K Dimensions (International Applications Only) LE4K06, K09 LE4K06, K09 LE4D09 to D806 A – – KM1 O – KM1 B LE8K06, K09 – ...

Page 175

... LP1D1801 LP1D2510 LP1D2501 LP1D3210 LP1D3201 LP1D4011 LP1D5011 LP1D6511 LP1D8011 LP1D11500 LP1D15000 4-Pole DC Contactors (2) LP1D12004 LP1D12008 LP1D25004 LP1D25008 (2) Coil voltages: codes to be added to the end of the new catalog numbers Volts dc Voltage Code 01/04 for Ring Terminal Type New Catalog No. Old Catalog No. ...

Page 176

... Cables with or without Cable End Old Catalog No. LP4D0910 LP4D0901 LP4D1210 LP4D1201 LP4D1810 LP4D1801 LP4D2500 3-Pole Reversing Contactors, Low Consumption (1) LP5D0910 LP5D1210 LP5D1810 LP5D2500 (1) Coil voltages: codes to be added to the end of the new catalog numbers Low Consumption Volts Code 3-Pole Reversing Contactors, AC ...

Page 177

Thermal Overload Relays For Use with Balanced Loads Old Catalog No. LR2D1301 LR2D1302 LR2D1303 LR2D1304 LR2D1305 LR2D1306 LR2D13X6 LR2D1307 LR2D1308 LR2D1310 LR2D1312 LR2D1314 LR2D1316 LR2D1321 LR2D1322 LR2D2353 LR2D2355 LR2D1508 LR2D1510 LR2D1512 LR2D1514 LR2D1516 LR2D1521 LR2D1522 LR2D2553 LR2D3322 LR2D3353 LR2D3355 LR2D3357 ...

Page 178

Schneider Electric All Rights Reserved 01/04 ...

Page 179

... Solid State Overload Relays Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 221 Dimensions and Mountings 222 Wiring Diagrams and Special Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 CR1F/CR1B Magnetic Latching Contactors Characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 225 Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 230 Accessories – Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 Mechanical Interlocks and Power Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . 232 Coils and Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 234 Dimensions and Mounting ...

Page 180

Schneider Electric All Rights Reserved 01/04 ...

Page 181

... General Information The F-line contactors and overload relays offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes. They offer high reliability with long mechanical and electrical life and the most complete line of accessories in the industry ...

Page 182

... In the least favorable direction, without change of contact state (coil at Vc). c Paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. q Sine wave without interference, above these values, please consult your Local Square D Field Sales Office. p 182 © 2001-2004 Schneider Electric All Rights Reserved ...

Page 183

... Wire pressure screw In the least favorable direction, without change of contact state (coil at Vc). c Paralleling of poles must be carried out only in accordance with the fuse manufacturer's recommendations. q Sine wave without interference, above these values, please consult your Local Square D Field Sales Office. p 01/04 LC1F330 LC1F400 ...

Page 184

... Mechanical latching The LA6DK mechanical latch blocks cannot be mounted on LC1F contactors, for similar operation use CR1F magnetic latching contactors (see page 226). The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. ...

Page 185

... Mechanical latching The LA6DK mechanical latch blocks cannot be mounted on LC1F contactors, for similar operation use CR1F magnetic latching contactors (see page 226). The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. ...

Page 186

... Tightening torque Mechanical latching The LA6DK mechanical latch blocks cannot be mounted on LC1F contactors, for similar operation use CR1F magnetic latching contactors (see page 226). Operating times depend on the type of contactor electromagnet and its control mode. c The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. ...

Page 187

... Tightening torque Mechanical latching The LA6DK mechanical latch blocks cannot be mounted on LC1F contactors, for similar operation use CR1F magnetic latching contactors (see page 226). Operating times depend on the type of contactor electromagnet and its control mode. c The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. ...

Page 188

... Selection – Contactors Selection - Contactors Control Circuit Kilowatt Ratings for International Applications 2-, 3-, and 4-Pole Contactors Standard power ratings of 3-phase motors 50/ category AC-3 220 V 380 V 230 V 400 LC1F225 110 75 132 100 160 110 200 LC1F630 147 250 200 335 220 400 ...

Page 189

... Control Circuit Horsepower Ratings for North American Applications 2-, 3-, and 4-Pole Contactors Standard power ratings of 3-phase motors 50/ category AC-3 200 V 208 V HP LC1F225 Current Rated 60 75 100 LC1F630 150 250 Current Rated — Note: For auxiliary contact blocks and modules (see pages 195 to 196). ...

Page 190

... Mechanical Interlocks and Power Connections Mechanical Interlocks and Power Connections Components for Assembling 3-Pole Reversing Contactors and Changeover Contactor Pairs, for Customer Assembly Horizontally mounted Reversers assembled using 2 contactors of identical rating, type: LC1F115 LC1F150 LC1F185 LC1F225 LC1F265 LC1F330 LC1F400 LC1F500 LC1F630 ...

Page 191

... LC1F500 LC1F630 or F800 LC1F780 To order the 2 contactors: see pages 188 and 189. Order 2 contact blocks LA1DN 1 to obtain electrical interlocking between the 2 contactors: see c pages 194 and 195. All power connections are to be made by the customer, except for contactors type LC1F780. ...

Page 192

... LC1F150 or F1504 LC1F185 or F1854 LC1F225 or F2254 LC1F265 or F2654 LC1F330 or F3304 LC1F400 or F4004 LC1F500 or F5004 LC1F630 or F6304 LC1F800 Reversers assembled using 3 contactors of identical or different ratings, type: LC1F115 or F1154 LC1F150 or F1504 LC1F185 or F1854 LC1F225 or F2254 LC1F265 or F2654 LC1F330 or F3304 LC1F400 or F4004 LC1F500 or F5004 ...

Page 193

... LC1F500 or F5004 For assembly of 3-pole changeover contactor pairs, see pages 190 and 191 order the 2 contactors: see pages 188 and 189. Order 2 contact blocks LADN 1 to obtain electrical interlocking between the 2 contactors: see c pages 194 and 195. All power connections are to be made by the customer, except for contactors type LC1F780. ...

Page 194

Auxiliary Contacts and Timers Auxiliary Contacts and Timers aaa LADN10 LC1F LADN01 194 © 2001-2004 Schneider Electric All Rights Reserved LADN LADN LADC LADT LADS LADR LA1DX, LA1DY, LA1DZ 01/04 ...

Page 195

... Contactors and Reversing Contactors Type LC1F Auxiliary Contact Blocks and Interface Module Instantaneous Auxiliary Contact Blocks For use in normal operating environments Number of contacts With terminal referencing conforming to standard EN 50012 2 4 See page 216 for actual markings. l Instantaneous Auxiliary Contact Blocks For use in harsh industrial environments ...

Page 196

... Accessories and Spare Parts Accessories and Spare Parts LA9D09981 Contactors and Reversing Contactors Type LC1F Suppressor Blocks and Cabling Accessories Suppressor Blocks Type of Suppressor RC (Resistor-Capacitor) LA9F980 Varistor Bi-directional Diode Diode LA9F 602 Mounting bracket (for 35mm DIN rail or panel mounting) for suppressor block ...

Page 197

... For use on Contactors LC1F115 LC1F150, F185 LC1F225, F265. F330, F400 LC1F500 LC1F630, F800 LA9F 979 Connection Accessories For reversing contactors or star-delta contactors combined with a thermal overload relay For use on Contactors LC1F115 LC1F150 and F185 LC1F225 and F265 LC1F330 and F400 LC1F400 ...

Page 198

... These clear plastic protective shrouds are an effective means to meet international touch-safe requirements for power terminals. They are designed to be used with power cables that have been bolted to the terminal. Note: The protection shrouds do not attach to contactors or overloads utilizing DZ2F lug kits. ...

Page 199

... Contactors and Reversing Contactors Type LC1F Spare Parts Main Contact Sets Per pole: 2 stationary contacts and 1 moving contact, 2 deflectors, 1 leaf spring, screws and washers For contactor 2-pole LA5FG431 3-pole 4-pole Arc Chambers LA5F40050 For contactor 2-pole 3-pole 4-pole Comprising 2 identical items per pole. ...

Page 200

F-line Voltage Code Table F-line Voltage Code Table F-line Voltage Code F-line (see notes at end of table) LC1F115 LC1F265 Voltage Frequency - F225 - F400 Note F1, Note F1 Low - - Consump DC 50/60 - ...

Related keywords