HMC1052 Honeywell Microelectronics & Precision Sensors, HMC1052 Datasheet - Page 2

SENSOR MAGN 2 AXIS 10-MSOP

HMC1052

Manufacturer Part Number
HMC1052
Description
SENSOR MAGN 2 AXIS 10-MSOP
Manufacturer
Honeywell Microelectronics & Precision Sensors
Type
Linearr
Datasheet

Specifications of HMC1052

Output Type
Differential Voltage
Sensing Range
±6g
Voltage - Supply
1.8 V ~ 20 V
Features
Compass - Two Axis
Operating Temperature
-40°C ~ 125°C
Package / Case
10-MSOP
Supply Voltage
3V
Sensitivity Range
1.2mV/V/G
Sensor Terminals
Through Hole
Leaded Process Compatible
No
Supply Current
10mA
Magnetic Field Max
6G
Axis Configuration
Two
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Current - Output (max)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
342-1029-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HMC1052
Manufacturer:
HMC
Quantity:
20 000
Part Number:
HMC1052L
Manufacturer:
Honeywell
Quantity:
2 401
Part Number:
HMC1052L
Manufacturer:
HMC
Quantity:
20 000
Part Number:
HMC1052L-TR
Manufacturer:
HONEYWELL
Quantity:
950
Part Number:
HMC1052L-TR
Manufacturer:
HONEYWELL
Quantity:
20 000
Part Number:
HMC1052M10
Manufacturer:
HITTITE
Quantity:
20 000
HMC1051/HMC1052/HMC1053
SPECIFICATIONS
Bridge Elements
Set/Reset Strap
Offset Straps
* Tested at 25°C except stated otherwise.
2
Characteristics
Supply
Resistance
Operating Temperature
Storage Temperature
Humidity
Field Range
Linearity Error
Hysteresis Error
Repeatability Error
Bridge Offset
Sensitivity
Noise Density
Resolution
Bandwidth
Disturbing Field
Sensitivity Tempco
Bridge Offset Tempco
Bridge Ohmic Tempco
Cross-Axis Effect
Max. Exposed
Field
Sensitivity Ratio of
X,Y Sensors
X,Y sensor
Orthogonality
Resistance
Current
Resistance Tempco
Resistance
Offset
Constant
Resistance Tempco
0.1% duty cycle, or less, 2 sec current pulse
Cross field = 1 gauss, Happlied = ±1 gauss
Measured from OFFSET+ to OFFSET-
Sensitive direction in X and Y sensors
Use S/R pulse to restore sensitivity.
Full scale (FS) – total applied field
No perming effect on zero reading
Field applied in sensitive direction
Magnetic signal (lower limit = DC)
T
T
T
Field = 0 gauss after Set pulse
A
T
Vbridge=5V, T
50Hz Bandwidth, Vbridge=5V
A
= -40 to 125°C, With Set/Reset
Measured from S/R+ to S/R-
Sensitivity starts to degrade.
A
Vbridge referenced to GND
A
= -40 to 125°C, No Set/Reset
3 sweeps across ±3 gauss
3 sweeps across ±3 gauss
= -40 to 125°C, Ibridge=5mA
Offset = (OUT+) – (OUT-)
Set/Reset Current = 0.5A
= -40 to 125°C, Vbridge=5V
Bridge current = 10mA
@ 1kHz, Vbridge=5V
Best fit straight line
Ambient, unbiased
T
T
T
Tested at 85°C
(HMC1052 Only)
A
A
A
Conditions*
= -40 to 125°C
= -40 to 125°C
= -40 to 125°C
(HMC1052)
DC Current
± 1 gauss
± 3 gauss
± 6 gauss
Ambient
A
= -40 to 125°C
-3000
-1.25
2100
3300
3500
Min
800
1.8
-40
-55
0.8
0.4
20
95
12
-6
3
-2700
± 500
1000
± 0.5
2500
3700
3900
-600
0.06
± 10
Typ
120
100
3.0
0.1
0.5
1.8
0.1
1.0
4.5
0.5
50
15
10
5
9
10000
+1.25
-2400
2900
1500
4100
4300
Max
0.01
125
150
105
1.2
20
85
+6
18
6
4
www.honeywell.com
mV/V/gauss
nV/sqrt Hz
mA/gauss
ppm/°C
ppm/°C
ppm/°C
ppm/°C
ppm/°C
degree
gauss
gauss
gauss
Units
ohms
mV/V
ohms
ohms
Volts
%FS
%FS
%FS
gauss
%FS
MHz
Amp
°C
°C
%
%

Related parts for HMC1052