VC2GU SQUARE D, VC2GU Datasheet - Page 36

SWITCH, DISCONNECT, 25A, 3POLE

VC2GU

Manufacturer Part Number
VC2GU
Description
SWITCH, DISCONNECT, 25A, 3POLE
Manufacturer
SQUARE D
Datasheet

Specifications of VC2GU

No. Of Poles
3
Contact Voltage Ac Max
600V
Contact Current Ac Max
25A
Mounting Type
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Class 9423 Vault Type for Single and Multi-Door Enclosures
Single or Multi-Door Enclosures — NEMA Type 12 with 40" to 60" Door Opening
The requirements are shown in the table below:
Viewed from Inside Enclosure
k Interlocking lever extension of the flange mounted handle mechanism.
j Actual enclosure opening – not door height.
v Screwdriver interlock assembly can be ordered separately. Class 9423
Note: All mechanisms listed on this page are
suitable for either left or right hand mounting.
36
1 – M6 door closing
1 – Type M660 locking bar kit
Type CEQ2493.
mechanism
Type M6
Without Interlocking
Auxiliary Door
Locking
Type M5
Single-Door Enclosure
Bar
Locking
Bar
1/4" Dia. Rod (Supplied By User)
1 – M6 door closing
1 – Type M660 locking bar kit
1 – Type M5 (use with 9422A
Opening
Door j
Type M7
mechanism
handles)
Locking
(Single Door)
Locking
Master Door
jj
With Interlocking
Bar
Bar
Type M2
k
© 1997 Square D All Rights Reserved
For each door:
1 – M6 door closing
1 – Type M660 locking bar kit
Required Accessories for Auxiliary Doors
TYPE M6 DOOR CLOSING MECHANISM
The Class 9423 Type M6 door closing mechanism is designed to close and seal 0.75” deep doors
of single or multi-door NEMA Type 12 enclosures. The Type M6 can be used on doors hinged on
either the left or right hand side. Recommended door openings are from 40" – 60". Vault type han-
dle length is 6".
TYPE M660 LOCKING BAR KITS
The lock bar kit for the Type M6 door closing mechanism contains two lock bars and is available
from stock. The bars can be cut to fit door openings through 60". One lock bar kit is required for
each Type M6 ordered.
TYPE M5
The Class 9423 Type M5 mechanical interlock kit is designed to interlock a Class 9422 handle
mechanism with the Type M6 door closing mechanism. This kit prevents opening the master door
(or single door) with the disconnect handle in the “ON” position, making it mandatory to use a
screwdriver to gain entry to the enclosure, regardless of the disconnect handle position.
TYPE M2
One Type M2 kit is required for each auxiliary door. This kit is required to interlock any auxiliary
door(s) with the master door.
TYPE M7
The first auxiliary door requires 2 Type M7 kits. Additional auxiliary doors require only 1 Type M7
kit. The 0.25” diameter rod used to interconnect the M7 kits is furnished by the user. If the distance
between any two Type M7 kits exceeds 36", an additional Type M7 kit should be installed to pre-
vent the rod from buckling.
mechanism
Without Interlocking
For Master door:
1 – M6 door closing
1 – Type M660 locking bar kit
1 – Type M5
mechanism
(use with 9422A handles)
Multi-Door Enclosure
With Interlocking
Each Auxiliary door:
1 – M6 door closing
1 – Type M660 locking bar kit
Necessary quantities of Types
M2 and M7 for each door
(see below)
mechanism
12/97

Related parts for VC2GU