VC2GU SQUARE D, VC2GU Datasheet - Page 38

SWITCH, DISCONNECT, 25A, 3POLE

VC2GU

Manufacturer Part Number
VC2GU
Description
SWITCH, DISCONNECT, 25A, 3POLE
Manufacturer
SQUARE D
Datasheet

Specifications of VC2GU

No. Of Poles
3
Contact Voltage Ac Max
600V
Contact Current Ac Max
25A
Mounting Type
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Enclosure with M6, M5, and Class 9422 Handle Mechanism
Enclosure with M8, M1, and Class 9422 Handle Mechanism
38
© 1997 Square D All Rights Reserved
Class 9423 Door Closing Mechanisms:
Single- and Multi-Door Enclosures
Enclosure Construction and General Location Information for
Types M5 and M6 and Types M1 and M8
Drilling and location information shown to the left is complete for a single door
enclosure with door hinged on the left side. The top drawing shows a Type
M6, M5, and Class 9422 handle mechanism; the bottom drawing shows a
Type M8, M1, and Class 9422 handle mechanism.
Transpose all horizontal dimensions for doors hinged on the right side.
See the next page for information on flange and channel construction.
Dimension A
For single-door enclosures and multi-door enclsoures without overhead
interlocking system, minimum is 1" (25mm). For multi-door enclosures with
an overhead interlocking system, minimum is 4.5" (114mm). (The overhead
interlocking system consists of the required number of Class 9423 Type M2
and M7 kits for interlocking the auxiliary doors with the master door; see pag-
es 34 and 35 for further information.)
Dimensions B and C
With M6, M5, and Class 9422 Handle Mechanism
TCF, TCN
TDF, TDN
TEF, TEN
TF
TG
RG1
RN1
RP1
RR2
RT1
With M8, M1, and Class 9422 Handle Mechanism
TCF, TCN
TDF, TDN
TEF, TEN
TF
TG
RG1
RN1
RP1
RR2
RT1
Type
30A Disconnect Switch
60A Disconnect Switch
100A Disconnect Switch
200A Disconnect Switch
400A Disconnect Switch
GJL Circuit Breaker
FAL, FHL Circuit Breaker
KAL, KHL Circuit Breaker
ILL Circuit Breaker
MAL, MHL, MEL, MXL
CIrcuit Breaker
30A Disconnect Switch
60A Disconnect Switch
100A Disconnect Switch
200A Disconnect Switch
400A Disconnect Switch
GJL Circuit Breaker
FAL, FHL Circuit Breaker
KAL, KHL Circuit Breaker
ILL Circuit Breaker
MAL, MHL, MEL, MXL
CIrcuit Breaker
Disconnect Devices
11.63 (296)
15.07 (383)
11.16 (284)
17.97 (457)
18.63 (474)
11.13 (283)
14.57 (370)
10.66 (271)
17.47 (444)
18.13 (461)
5.25 (134)
4.85 (124)
4.85 (124)
4.75 (121)
4.35 (111)
4.35 (111)
If A = 1”,
3.44 (88)
3.44 (88)
2.94 (75)
2.94 (75)
Min B =
11.57 (294)
14.47 (368)
15.13 (385)
11.57 (294)
14.47 (368)
15.13 (385)
If A = 4.5”,
8.13 (207)
7.66 (195)
8.13 (207)
7.66 (195)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
2.50 (64)
Min B =
6.75 (172)
5.88 (150)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
3.19 (81)
12/97
C

Related parts for VC2GU