CV500RM211 Omron, CV500RM211 Datasheet

no-image

CV500RM211

Manufacturer Part Number
CV500RM211
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500RM211

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
SYSMAC
H-PCF Optical Fiber Cables
Installation Guide
Revised July 1993

Related parts for CV500RM211

CV500RM211 Summary of contents

Page 1

SYSMAC H-PCF Optical Fiber Cables Installation Guide Revised July 1993 ...

Page 2

...

Page 3

... All OMRON products are capitalized in this manual. The word “Unit” is also capitalized when it refers to an OMRON product, regardless of whether or not it appears in the proper name of the product. The abbreviation “Ch,” which appears in some displays and on some OMRON products, often means “ ...

Page 4

...

Page 5

                                                      ...

Page 6

About this Manual: This manual describes the installation of hard-clad PCF (H--PCF) Optical Fiber Cords and Cables and includes the sections described below. Information concerning individual components of the SYSMAC NET LINK, SYSMAC NET, SYSMAC BUS, SYSMAC BUS/2, and SYSMAC ...

Page 7

'+       +   +                       .                              ...

Page 8

Introduction to H-PCF Optical Fiber Cables On the outside, Optical Fiber Cords and Cables look like electrical cords and cables. However, instead of metal wires carrying electrical signals, Optical Fiber Cords and Cables use quartz-glass fibers with a hard-clad ...

Page 9

The following diagram shows the construction of the 2-C-V (2 CCV- HC-20/07): 1-2 Features of H-PCF Optical Fiber This section describes the basic features of H-PCF Optical Fiber Cables. Signal Loss vs. Wavelength H-PCF optical fibers have a stable signal ...

Page 10

The following graph shows the signal loss vs. distance characteristics given by the equations above. Numerical Aperture vs. The H-PFC optical fibers have a high NA value that the older PFC optical Fiber Length fibers lacked, as well as more ...

Page 11

The following graph shows transmission band vs. fiber length for DCV- HC-20/07 H-PCF Duplex Optical Fiber Cord with an LED light source of Signal Loss vs. The following graph shows signal loss vs. temperature for the older silicon- Temperature clad ...

Page 12

'+        +             .       +                              ...

Page 13

Component Materials and Dimensions These specifications apply to two-fiber H-PCF (hard plastic-clad optical fiber) Optical Fiber Cords and metallic-construction Optical Fiber Cables. Refer to Ap- pendix A Standard Models for ordering information. Two-fiber Optical Fiber Cord The following diagram ...

Page 14

Two-fiber Optical Fiber Cable The following diagram shows the construction of the two-fiber H-PCF Optical Fi- ber Cable. The diagram on the left shows the S3200-HCC not have power supply wires. The diagram on the right shows the S3200-HCL S3200-HCC ...

Page 15

S3200-HCL Cables The following table shows the specifications for S3200-HCL have power supply wires. General Optical fiber cord Power wire Tension member External jacket 2-2 Specifications These specifications apply to two-fiber H-PCF (hard plastic-clad optical fiber) Optical Fiber Cords and ...

Page 16

Transmission Characteristics Item Ambient temp.  Signal loss l=0.81 l=0.85 l=0.655 LED) LED) Transmission --- l=0.85 band  Signal loss at low --20 C l=0.81 temp.  Signal loss high temp --20 ...

Page 17

... Factory Inspection The items listed in the following table are checked at OMRON before shipping. Item Cladding diameter Refer to the tables in 2-1 Component Materials and Dimensions . External cord diameter Insulator thickness Jacket thickness External cable diameter   Signal loss ( =0.81 m) The 25 C ratings listed under the heading Trans- mission Characteristics in 2-2 Specifications ...

Page 18

...

Page 19

... Connectors The following diagrams show the OMRON crimp connectors used with H-PCF Optical Fiber Cords and Cables. All dimensions are in millimeters. S3200-COCH62M S3200-COCH82 8 The following table lists the applications and applicable models for each of the OMRON crimp connectors shown above. ...

Page 20

Applicable Connectors The following table lists the Units that can use crimp connectors and their appli- cable connectors. S3200-LSU03-01E S3200-NSUG4-00E S3200-NSUA1-00E S3200-NSB11-E C500-SNT31-V4 C500-RM001-(P)EV1 C500-RT001-(P)EV1 C500-RT002-(P)EV1 C500-LK010-(P)-E C500-LK103-(P) C500-LK101-(P)EV1 C200H-RM001-PV1 C200H-RT001-P C200H-RT002-P 3G2C7-LK011-(P) C200H-LK101-P C200H-SNT31 C200H-SLK11 C120-RM001(-P)-E C120-LK010-(P)-E 3G2A6-LK101-(P)EV1 CV500-SNT31 ...

Page 21

... Connector Components The following diagrams show the construction of the OMRON crimp connectors used with H-PCF Optical Fiber Cords and Cables. S3200-COCH62M Spring TC Color 4511 Plug 4511 Male NC-11 S3200-COCH62F Color 4511 Plug 4511 Sleeve M-FF Female FF-TM13 S3200-COCF2011 Plug Cap ...

Page 22

Connector Assembly The specialized connector assembly tools needed to attach connectors to the H-PCF Optical Fiber Cord or Cable on site must be purchased separately. All of the required tools are included in the Optical Connector Assembly Tool Kit ...

Page 23

Optical Connector The Optical Connector Assembly Tool Kit includes all of the tools required to at- Assembly Tool Kit tach the six optical connectors described in 3-1 Connectors . The following dia- gram shows the Optical Connector Assembly Tool Kit ...

Page 24

... Head Unit Set Master Fiber Set S3200-CAT3201 S3200-CAT2001H S3200-CAT2821 Wave- Applicable Optical Module length 850 nm DF-1100 DF-2100 DF-2200 810 nm DF-1700, TODX294 (OMRON) DF-1800 DF-2700 DF-2800 Section 3-4 Applicable Optical Connector S3200-COCH62M, S3200-COCF62M, S3200-COCH62F S3200-COCF2511, S3200-COCF2011 S3200-COCF2511, S3200-COCF2011 S3200-COCH82 Applicable Optical Connec- tors ...

Page 25

The following table lists the component parts of the Optical Power Tester Sets and Head Unit Sets. Optical Power Tester Set Component p S3200-CAT2000 Main Unit Model 205 Connector Adapter 180-HTL Light Source 310-085CF (yellow la- bel) AC Adapter DP-1005 ...

Page 26

Testing Optical Fibers with The amount of light transmitted through an optical fiber with crimp connectors at Two Crimp Connectors both ends should satisfy the ratings given in the following table. The maximum transmission distance for this configuration is 800 ...

Page 27

'+        +&               (    2     (   "                     ...

Page 28

... Elevated Wiring Not recommended. Buried Wiring Not recommended. Note 1. The outer sheath of cords and cables is PVC. Consult your OMRON dealer possible to bury a cable if special construction is used. Consult your OM- 4-3 Basic Installation Methods 4-3-1 Preparing a Cord for Pulling Optical Fiber Cords must not be pulled by their optical fibers, but by the cord’s reinforcement material ...

Page 29

Optical Fiber Cord. These methods will not make the end of the cord watertight. If the cord is being pulled through water, be sure to treat the end of the cord ...

Page 30

Example 3 If the cord is being pulled through a relatively large conduit, a cord can be folded back onto itself and taped ...

Page 31

Cable With a Connector Follow the procedure below to prepare an Optical Fiber Cable with a connector attached 3... 1. First remove any parts of the connector’s plastic housing that can be re- 2. Cover the Optical Fiber ...

Page 32

Multiple-stage Pulling With this method the cable is installed in one direction, but the cable is pulled through the route in stages. The remainder of the cable is temporarily piled in figure-eight layers at the end of each successive stage. ...

Page 33

Be sure to follow the precautions described above under the heading “one-way pulling” and eliminate any bends or twists in the cable after installation 3... 1. Pull or lay the cable from the starting point in the first ...

Page 34

Note Be sure to protect the connector on Optical Fiber Cords or Cables that have con- nectors attached. In particular, use a protective cap to prevent the tip of the con- nector from being contaminated by dirt. 4-4-2 Installation in ...

Page 35

Attach a bushing and saddles at the end of the con- duit so that the Optical Fiber Cable does not bend at too sharp an angle. Turns in the installation route should be avoided if possible, ...

Page 36

Insert bushings at the ends of the conduit and install guides to prevent sharp bends. 4-4-3 Installation in Ducts The instructions for installation in ...

Page 37

Gently unreel the Optical Fiber Cable at less than 10 m/min by spinning the reel, so that no pulling tension is applied to the Optical Fiber Cable itself. Be sure not to apply any force to the cable (tension, bending, ...

Page 38

Optical Fiber Cable When installed in a rack or trough, secure the cable with mounting brackets or saddles to prevent movement. Be sure not to attach the brackets or saddles too tightly, because excessive compression will damage the cable. Use ...

Page 39

H-PCF Two-fiber Optical Fiber Cord Connectors Tension Member No No H-PCF Two-fiber Optical Fiber Cable (Without Connectors) Connectors Tension Member No Yes No Note We will continue to accept orders for conventional cable models S3200-FH-L-C22T and B500-OF Appendix A Standard ...

Page 40

H-PCF Two-fiber Optical Fiber Cable (With Connectors) Tension Power Color Member Wires Yes Yes Black Both S3200-COCF2011 One S3200-COCF2011, one S3200-COCF2511 One S3200-COCF2011, one S3200-COCH62M Both S3200-COCF2511 One S3200-COCF2511, one S3200-COCH62M Both S3200-COCH62M Note We will continue to accept orders ...

Page 41

Optical Connectors Model Number Connection S3200-COCH62M Full lock S3200-COCF62M Relay (male) S3200-COCF62F Relay (female) S3200-COCH82 Half lock S3200-COCF2511 Half lock S3200-COCF2011 Full lock S3200-COIAT2000 Relay Optical Connector Assembly Tool Set Model Number S3200-CAK1062 S3200-COCH62M, S3200-COCF62M, S3200-COCF62F, S3200-COCF2511, S3200-COCF2011, S3200-COCH82 Note ...

Page 42

Master Fiber Sets Model Number S3200-CAT3201 S3200-CAT2001H S3200-CAT2821 Note The applicable Head Unit is determined by the connector adapter in the Head Unit that fits the master fiber. Applicable Head Unit S3200-CAT3202 S3200-CAT2002, S3200-CAT2702 S3200-CAT2822 Appendix A ...

Page 43

A unit for expressing power level in decibels, relative to a reference level of one milliwatt. ferrule A short tube which is attached to the end of an optical fiber and is part of the optical fiber connector. H--PCF ...

Page 44

 ...

Page 45

A manual revision code appears as a suffix to the catalog number on the front cover of the manual. Cat. No. W156-E1-3 The following table outlines the changes made to the manual during each revision. Page numbers refer to the ...

Page 46

... For US technical support or other inquiries: 800.556.6766 OMRON CANADA, INC. 885 Milner Avenue 1 5 Toronto, Ontario 416.286.6465 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.ca W156-E1-3 8 ©2002 OMRON ELECTRONICS LLC Printed in the U.S.A. Specifications subject to change without notice. ...