E5CN-R2MTD-500 ACDC24 Omron, E5CN-R2MTD-500 ACDC24 Datasheet

Digital Temperature Controller

E5CN-R2MTD-500 ACDC24

Manufacturer Part Number
E5CN-R2MTD-500 ACDC24
Description
Digital Temperature Controller
Manufacturer
Omron
Datasheet

Specifications of E5CN-R2MTD-500 ACDC24

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Output Voltage Max
240VAC
Output Voltage Min
5V
Controller Input
Thermocouple Or RTD
Thermocouple Type
J, K, T, E, L, U, N, R, S, B, W, PLII
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
New 48 x 48-mm Basic Temperature
Controller with Enhanced Functions and
Performance. Improved Indication
Accuracy and Preventive Maintenance
Function.
Main I/O Functions
• Indication Accuracy
• New E5CN-U Models (Plug-in Models) with analog inputs and
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
Basic-type Digital Temperature Controller
E5CN/E5CN-U
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
current outputs.
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or SV.
using a Control Output ON/OFF Counter.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
(Models with temperature inputs)
(Models with analog inputs)
Event Inputs
• None
• Two
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
• Long-life relay output (hybrid)
E5CN
Control Output 2
• None
• Voltage output
(for driving SSR)
2-level Display: PV and SV
Auxiliary Outputs
• None
• One
• Two
(48 x 48 mm)
Refer to Operation for E5
procedures.
Refer to Safety Precautions for E5
48 × 48-mm
E5CN
4-digit Display
• Auto/manual switching
• Temperature Controller status display
• Simple program function
• Control output ON/OFF count alarm
• PV change rate alarm
• Models also available with RS-485
communications
CSM_E5CN_E5CN-U_DS_E_5_1
@
N/E5
@
48 × 48-mm
N-H for operating
E5CN-U
@
N/E5
@
N-H.
1

Related parts for E5CN-R2MTD-500 ACDC24

E5CN-R2MTD-500 ACDC24 Summary of contents

Page 1

... This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions and other information required for operation before attempting to use the product. E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156) E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158) ( mm) 48 × ...

Page 2

... Temperature input 1 control output Analog input Option Units E53-CN@@@ Applicable Controller CN: E5CN or E5CN-H 2. Function 1 Blank: None Q: Control output 2 (voltage for driving SSR) P: Power supply for sensor 3. Function 2 Blank: None H: Heater burnout/SSR failure/Heater overcurrent detection (CT1) HH: Heater burnout/SSR failure/Heater overcurrent detection ...

Page 3

... Note: 1. Option Units cannot be used for plug-in models. These Option Units are applicable only to models released after January 2008 the E53-CNQHN2 or E53-CNQHHN2 Option Unit is used together with the E5CN-C@ Temperature Controller and control output 1 (current output) is assigned to the heating control output, heater burnout detection will be disabled. ...

Page 4

... Voltage output (for driving SSR) E5CN-Q2TU Current output Relay output 1 Voltage output (for driving SSR) E5CN-Q1LU Current output Analog (current/voltage) Relay output 2 Voltage output (for driving SSR) E5CN-Q2LU Current output Relay output None Voltage output (for driving SSR) E5CN-QTDU Current output Relay output Thermocouple or resistance 1 ...

Page 5

... USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models Terminal block models Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Model Y92S-29 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. Current Transformers (CTs) Hole diameter 5 ...

Page 6

... model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 VAC: 7.5 VA (max.) (E5CN-R2T at 100 VAC: 3.0 VA) E5CN Power 24 VAC/VDC: 5 VA/3 W (max.) (E5CN-R2TD at 24 VAC: 2.7 VA) consump- 100 to 240 VAC (max ...

Page 7

... JPt100: JIS C 1604-1989, JIS C 1606-1989 Pt100: JIS C 1604-1997, IEC 751 PL II: According to Platinel II electromotive force charts from BASF (previously Engelhard) Voltage E5CN/E5CN-U Infrared temperature sensor 115 140 120 II 70°C 165 260 °C °C °C ...

Page 8

... Controllers User's Manual Basic Type (Cat. No. H156) for H < > 0 ⏐H⏐ ≥ ⏐L⏐ information on the loop burnout alarm (LBA *8. Refer to the E5CN/E5AN/E5EN/E5GN Digital Temperature H > < 0 Controllers User's Manual Basic Type (Cat. No. H156) for ⏐H⏐ ≤ ⏐L⏐ information on the PV change rate alarm ...

Page 9

... Non-volatile memory (number of writes: 1,000,000 times) Setup Tool CX-Thermo version 4.0 or higher Provided on the bottom of the E5CN. Use this port to connect a computer to the E5CN when using the Setup Tool. An E58-CIFQ1 Setup Tool port USB-Serial Conversion Cable is required to connect the computer to the E5CN. *6 Approved UL 61010-1, CSA C22 ...

Page 10

... ON, and the output assigned to the alarm 1 function will turn ON if the heater current is higher than the set value (i.e., heater overcurrent detection current value). Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 100 E5CN 250 VAC, 30 VDC 3 (resistive load) cosφ ...

Page 11

... DO NOT USE B Input power supply B • 100 to 240 VAC TC/Pt universal input • 24 VAC/VDC (no polarity) E5CN/E5CN-U A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned. E53-CNPHN2 E53-CNP03N2 External Power Communications (RS-485) ...

Page 12

... Nomenclature E5CN E5CN-U The front panel is the same for the E5CN and E5CN-U. Operation indicators Dimensions E5CN Terminal Models 48 × Waterproof Packing (Accessory) E5CN-U Plug-in Models 48 × Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 Temperature unit Level Key Mode Key Down Key ...

Page 13

... Two, 3.5 dia. 2.36 dia dia. 9 Two, M3 (depth: 4) Armature Lead E5CN/E5CN-U E54-CT1 Thru-current (Io) vs. Output Voltage (Eo) (Reference Values) Maximum continuous heater current (50/60 Hz) Number of windings: 400±2 Winding resistance: 18±2 Ω 100 ∞ 10 Distortion 1 kΩ ...

Page 14

... Note: 1. Using any other sockets will adversely affect accuracy. Use only the specified sockets Protective Cover for finger protection (Y92A-48G) is also available. 4.7 69.6 to 77.6 72 × 72 Panel ( mm) 72 × × 48 2.2 4.7 77.3 (to back of E5CN) Terminal Layout/Internal Connections 3 4.5 7.8 (Top View 35.4 Two ...

Page 15

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...