Watt Meter

10770

Manufacturer Part Number10770
DescriptionWatt Meter
ManufacturerSimpson
10770 datasheets
 


Specifications of 10770

Meter FunctionWattMeter Range0W To 1500W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-1500 WEquipment TypeWattage Meter
Range0 - 1500Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
2
3
4
5
6
7
8
9
10
11
Page 11
12
Page 12
13
Page 13
14
Page 14
15
Page 15
16
Page 16
17
Page 17
18
Page 18
19
Page 19
20
Page 20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Page 19/68

Download datasheet (7Mb)Embed
PrevNext
• Four model types designed to fit a wide
range of applications
• One meter to measure all your values
• Easy installation - software detection/
correction of wiring errors
• Wide backlit LCD display for easy viewing
• Easy to use - four keys select all parameters
• Use for single or three-phase applications
Specifications
INPUT
System
3-phase, 3 or 4 wire unbalanced load
Voltages
120/208, 120/240, 277/480, 63/110
0.5% to 120%
Measurement range
Current
5 amp from external CTs Fully Isolated
Measurement range
0.5% to 120%
Operating Frequency
45 to 65 Hz
Harmonics
Up to the 20th harmonic
Input Loading
Voltage
Less than 0.1VA per phase
Current
Less than 0.1VA per phase
Overload
x2 for 2 seconds max.
Voltage
x40 for 1 second max.
Current
Auxiliary Supply
Standard
115V±15% 45-65Hz
Optional
230V±15% 45-65Hz
General Display
Custom backlit supertwist LCD 3 lines of .47”
(12mm) digits plus .15” (3.8mm) legends
ENVIRONMENTAL
Temperature
14°F to 149°F (-10°C to 65°C) operating
Humidity
<75% RH non-condensing
Programming
CT Primary
5amp to 6500 amp
VT Primary
60v to 50,000v
Pulse Outputs
2
Function
Output No. 1
Wh (G200, G300 & G400 only)
Output No. 2
Total varh (G300 & G400 only)
Pulse Length
100ms
Isolation
2500V (50 Output No. 1 to Output No. 2)
Scaling
Settable 1, 10 or 100 pulse output rate
ACCURACY
Current
Per Phase
5% to 120%FS
±0.2%FS
Voltage LN
±1% Rdg*
20% to 120%FS
±0.2%FS
Voltage LL
±1% Rdg*
20% to 120%FS
±0.3%FS
Watts
±1% Rdg*
5% to 120%FS
±0.4%FS
VA
±1% Rdg*
5% to 120%FS
±0.6%FS
var
±1.5% Rdg*
5 % to 120%FS
±0.8%FS
PF
±2% Rdg*
Frequency
±0.2°
Neutral Current
5% to 120%FS
Wh Register
N/A
VAh Register
N/A
Varh Register
N/A
N/A
N/A
Note:
All accuracies specified are ±1 digit
*Rdg = Reading
MECHANICAL
Bezel
2.77” x 3.79” (w/ .28” lip)
Depth
2.83”
Panel Cutout
3.62” x 3.62”
Weight
14 oz.
Height
3.79”
A
15
3 Phase
N/A
N/A
N/A
±0.6%FS
±1% Rdg*
±1%FS
±1.5% Rdg*
±1.5% FS
±2% Rdg
±0.2°FS
±0.05 Hz
±0.6% FS
±2% Rdg
Class 1
EN 61036
Class 2
Class 2
IEC 1268
more >>