Watt Meter

10770

Manufacturer Part Number10770
DescriptionWatt Meter
ManufacturerSimpson
10770 datasheets
 

Specifications of 10770

Meter FunctionWattMeter Range0W To 1500W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-1500 WEquipment TypeWattage Meter
Range0 - 1500Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
Page 21
22
Page 22
23
Page 23
24
Page 24
25
Page 25
26
Page 26
27
Page 27
28
Page 28
29
Page 29
30
Page 30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
Page 24/68

Download datasheet (7Mb)Embed
PrevNext
A
20
• Easily programmed from the front panel
• Remote Reset capability
• Input variety: Quadrature, Switch, TTL,
CMOS, NAMUR, PNP, NPN
• Software functions include:
Password
Set Point Programming
The S662 is a multi-function counter that can be easily configured to
operate either in a dual mode or in a totalizing/batch mode, each
with separate scaling and reset functions. When functioning in the
dual mode, full direction control is maintained for the totalizing and
batch counts. In the totalizing batch mode, the secondary value
(batch count) is incremented after the primary totalizing count has
completed its cycle.
The counter is powered from 120 or 240VAC and has a non-volatile
EEPROM to retain all programming and count information when the
power source is removed or interrupted. An option 12DCV excitation
output module can provide power for external sensors.
This versatile counter has latching, boundary or timed (0.01 to
599.99 seconds) output modes.
Mounting Requirements
The S660 series 1/8 DIN counters require a panel cutout of 1.77"
(45mm) high by 3.62" (92mm) wide. To install the counter into a
panel cutout, remove the clips from the side of the meter. Slide the
meter through your panel cutout, then slide the mounting clips back
on the meter. Press evenly to ensure a proper fit.
Panel Cutout Dimensions on page A23
Specifications
DISPLAY
Type
Height
Decimal Point
Count Direction
Display Range
Output Indicators
POWER REQUIREMENTS
AC Voltages
Power Consumption
INPUT RATINGS
Current Sinking
Current Sourcing
Minimum Pulse Width
Low Pass Filter
Low Bias
High Bias
Count Rate
Maximum Voltage Input
A, B, and User
INPUT
User Input
Standard Input
Display Scaling
Quadrature Input
Decimal Point Selection
ENVIRONMENTAL
Operating Temp.
Storage Temp.
Relative Humidity
Ambient Temperature
Temp. Coefficient (per °C)
Warmup Time
MECHANICAL
Bezel
Depth
Panel Cutout
Case Material
Weight
Ordering Information
Basic Unit
S662
6-digit, 7-segment, red LED
0.56" (14.2mm)
User-programmable
"+" indication implied, "-" indication displayed
-99,999 to +999,999
1 and 2
120, 240VAC, ±10%
3VA
10K , 5% Resistor pull-up to (9.0 - 16DCV) ±10%
5.1K , 5% Resistor pull-down to common
~5µs
<200Hz
VLT = 1.6V ±10% VUT = 3.6V ±10%
VLT = 5.0V ±10% VUT = 7.0V ±10%
20KHz (Pulse Max) 5KHz (Quadrature X4 Max)
30DCV (Max)
(Second channel reset) Count on the second chan-
nel is reset when the User Input is pulled low.
VLT
0.2DCV guaranteed low, VUT = 3.0DCV (max)
VLT
0.9DCV VUT =3.15DCV (max)
0°C to +40°C
-10°C to +60°C
0-80% non-condensing for temperatures less
than 32°C, decreasing linearly to 50% at 40°C
25°C
±100ppm/ °C
15 minutes
3.93" x 2.04" x .52" (99.8mm x 51.8mm x 13.2mm)
3.24" (82.3mm)
3.62" x 1.77" (92mm x 45mm)
PBT-ABS
9oz (255.1g)
Output
Power Supply
None
0
120 ACV
1
One Relay
1
240 ACV
2
Two Relays
2
Input
Excitation
Standard
1
Quadrature
12DCV
2
(100mA max cur-
Other
None
0
None
0
1
rent)