Watt Meter

10770

Manufacturer Part Number10770
DescriptionWatt Meter
ManufacturerSimpson
10770 datasheets
 


Specifications of 10770

Meter FunctionWattMeter Range0W To 1500W
Meter Size/dimensions4.5 In.Scale Length89mm
Meter ShapeRectangularDisplay Accuracy ±2%
Accuracy+/-2 %Barrel Size2.83"
Power Meter Range0-1500 WEquipment TypeWattage Meter
Range0 - 1500Size4.50 in
Meter MovementDynamometerRohs CompliantNA
Lead Free Status / RoHS Statusna  
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
Page 51
52
Page 52
53
Page 53
54
Page 54
55
Page 55
56
Page 56
57
Page 57
58
Page 58
59
Page 59
60
Page 60
61
62
63
64
65
66
67
68
Page 57/68

Download datasheet (7Mb)Embed
PrevNext
• Wide Variety of Control, Alarm, and Limit
Use
• Calibration Not Affected by Steel Panel
Mounting
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Proof
Dimensions
4 - 1/2”-Model 3344AIXA & 3324AIXA
=
1
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
AC: ±3% of full scale; DC: ±2% F.S.
Movement:
Annular, self-shielding
Suspension:
Pivot and jewel
Tracking:
±3%
Repeatability:
Within 0.5% F.S.
Shielding:
Calibration is unaffected by magnetic panel mounting
Response Time:
1.5 seconds maximum above 10mA
Overload (1 sec.):
AC: 7 amps; DC: 10 times F.S.
Overload (Continuous):
AC: 7 amps, DC: 1.5 times F.S.
Dial:
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Case:
Sealed metal, plastic window
Voltage Drop:
50mV
Pointer:
Black, knife-edge
Scale Length:
4.05" (103.0mm)
Net Weight:
17oz (0.48kg)
Control Point(s)
Single, high limit, 0-100% of arc; double, low limit 0-
Adjustments:
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Switching:
Within 1% of indication
Differential:
“On,” “Off” difference is within 0.5% of F.S.
Auto/Manual Reset:
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
Contacts/Output Relay:
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
Frequency Response:
50-1000Hz
Power:
108-132 VAC, 50-400Hz
Operating Temperature:
+41°F to 122°F (5°C to +50°C)
Circuit-to-Ground
Voltage:
250V rms maximum
NOTE:
DC meters meet ANSI specification C-39.1
3 - 1/2”-Model 3343AIXA & 3323AIXA
B
29