3RW3018-1BB14 SIEMENS, 3RW3018-1BB14 Datasheet

SIRIUS SOFTSTARTER, S00, 17.6A, 7.5KW

3RW3018-1BB14

Manufacturer Part Number
3RW3018-1BB14
Description
SIRIUS SOFTSTARTER, S00, 17.6A, 7.5KW
Manufacturer
SIEMENS
Datasheet

Specifications of 3RW3018-1BB14

Supply Voltage Range
200Vac To 480Vac
No. Of Phases
Three
Power Rating
7.5kW
Current Rating
17.6A
Operating Temperature Range
-25°C To +60°C
Approval Bodies
CE, IEC, UL, CSA
Control
RoHS Compliant
© Siemens AG 2008
3RW30/3RW40 Soft Starters
Catalog News LV 1 N
January 2008
www.siemens.com/automation

Related parts for 3RW3018-1BB14

3RW3018-1BB14 Summary of contents

Page 1

... Soft Starters Catalog News www.siemens.com/automation © Siemens AG 2008 January 2008 • ...

Page 2

... Registered trademarks All product designations may be registered trademarks or product names of Siemens AG or other supplying companies. Third parties using these trademarks or product names for their own purposes may infringe upon the rights of the trademark owners. Further information about low-voltage controls is available on the Internet at: http://www ...

Page 3

... Chapter 6, Load Feeders, Motor Starters and Soft Starters, Section: 3RW30 and 3RW40 Soft Starters Contact your local Siemens representative for further information © Siemens AG 2008 The products and sys- tems listed in this cata- log are manufactured using a certified quality management system ...

Page 4

...

Page 5

... Introduction Siemens Automation and Drives. Welcome. Sharpen your competitive edge. Totally Integrated Automation. Integrated energy distribution from a single source. Totally Integrated Power. Low-Voltage Controls and Distribution - The basis for progressive solutions. SIRIUS Industrial Controls Low-Voltage Power Distribution 2 Systems AS-Interface ECOFAST System ...

Page 6

... The Technical Information saved as a PDF file on the CD-ROM which is enclosed with this catalog (inside front cover). The delivery times apply up to the ramp at Siemens AG (products ready for dispatch). The transport times depend on the destination and type of shipping. The standard transport time for Germany is 1 day. ...

Page 7

... Function 6/12 - Technical specifications 6/21 - Characteristic curves 6/21 - More information 3RW40 for standard applications 6/23 - Function 6/24 - Technical specifications 6/34 - Characteristic curves 6/35 - More information Project planning aids 6/37 - Dimensional drawings 6/39 - Schematics Siemens SIRIUS Soft Starters · 01/2008 ...

Page 8

... Available for 3RW40 2. to 3RW40 4.; optional for 3RW40 5. and 3RW40 7.. 4) Calculate soft starter and motor with size allowance where required. 6/2 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 • Reduction of the mechanical load in the operating mechanism • Considerable space savings and reduced wiring compared with conventional starters • ...

Page 9

... Application areas • Pumps • Heat pumps • Hydraulic pumps • Presses • Conveyors • Roller conveyors • Screw conveyors Siemens SIRIUS Soft Starters · 01/2008 3RW30 for standard applications 6/3 ...

Page 10

... With screw terminals • With spring-loaded terminals 1) Stand-alone installation. 2) Soft starter with screw terminals: delivery time class 3) Main circuit connection: screw terminals. 6/4 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW30 38-1BB14 3RW30 47-1BB14 Size DT Order No. e 230 V ...

Page 11

... S3 3RA19 41-1A 3ZX10 12-0RW30-2DA1 Use DT Order No. } For devices 3RP19 02 with contacts } For devices 3RP19 03 with contacts Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW30 for standard applications Price PU PS* PG Weight per PU (UNIT, per PU SET, M) approx unit 101 0.035 ...

Page 12

... Catalog LV 1 "Appendix" –> "Standards and approvals" –> "Type overview of approved devices for explosion-protected areas (ATEX explosion protection)". 6/6 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Application The SIRIUS 3RW40 solid-state soft starters are suitable for soft starting and stopping of three-phase asynchronous motors ...

Page 13

... Siemens recommends the use of the selection and simulation program Win-Soft Starter. For information about rated currents for ambient temperatures > 40 °C, see technical specifications. Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications ...

Page 14

... Order No. supplement for connection types • With screw terminals 3) • With spring-loaded terminals 1) Stand-alone installation without auxiliary fan. 2) Soft starter with screw terminals: delivery time class 3) Main circuit connection: screw terminals. 6/8 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW40 38-1TB04 Size DT Order No ...

Page 15

... J Load Motor deviating conditions or increased switching frequency, it may be necessary to choose a larger device. Siemens recommends the use of the selection and simulation program Win-Soft Starter. For information about rated currents for ambient temperatures > 40 °C, see technical specifications. * You can order this quantity or a multiple thereof. ...

Page 16

... For Ø 6.5 mm holes in the control panel; max. control panel thickness 8 mm 3RW40 5. and S6, 3RW40 7. S12 1) Remote RESET already integrated in the soft starters 3RW40 2. to 3RW40 4.. 6/10 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Version DT Order No • 3RT19 55- • ...

Page 17

... DT Order No. Rated control supply voltage U s 115 3RW49 36-8VX30 230 3RW49 36-8VX40 115 3RW49 47-8VX30 230 3RW49 47-8VX40 Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications Price PU PS* PG Weight per PU (UNIT, per PU SET, M) approx units 101 ...

Page 18

... IN command) Missing mains voltage, phase failure, missing load Device fault 6/12 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 It creates a motor ramp-up that is uniform in speed, torque and current rise, thus permitting a particularly gentle, two-phase starting of the motors. At the same time the acoustic quality of the starting operation comes close to the quality of a three- phase controlled soft starter ...

Page 19

... A 3 5.5 W 0.25 0 3.6 6.5 1/h 200 87 A 3.6 6.5 1/h 150 °C, stand-alone u Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW30 for standard applications Factory default 7.5 40 10° 3RW30 16 3RW30 17 3RW30 18 9 12.5 17 12.5 17.6 ...

Page 20

... starts per hour 1) Measurement at 60 °C according to UL/CSA not required. 2) With 300 % For intermittent duty S4 with ON period = installation vertical. The quoted switching frequencies do not apply for automatic mode. 6/14 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW30 ...

Page 21

... AWG 2 x (20 ... 14) AWG 2 x (20 ... 16) Nm 0.8 ... 1.2 lb.in 7 ... 10 (0.25 ... 2. (0.25 ... 1.5) AWG 2 x (24 ... 14) Siemens SIRIUS Soft Starters · 01/2008 3RW30 for standard applications 3RW30 3. 3RW30 (1.5 ... 16 (2.5 ... 16 (0.75 ... 25 (2.5 ... 35 (0.75 ... 35 ... 70 (18 ... (10 ... 2/ (1.5 ... 16 (2.5 ... 16 ...

Page 22

... AWG cables, solid or stranded 1) The rated motor current (specified on the motor's name plate) should at least amount to the specified percentage of the SIRIUS soft starter unit's rated operational current 6/16 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW30 ... 230 AC/DC ± ... 4 ...

Page 23

... Not required for 3RW30 1. and 3RW30 2.; required for 3RW30 3. and 3RW30 4. (see table) 1) Recommended filters Voltage range 200 ... 480 V Filter types Rated current filters A 4EF1512-1AA10 50 4EF1512-2AA10 66 4EF1512-3AA10 90 4EF1512-3AA10 90 4EF1512-4AA10 120 Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW30 for standard applications Terminals 6/17 ...

Page 24

... The types of coordination are explained in more detail in Catalog LV 1, "Load Feeders, Motor Starters and Soft Starters" ––> "Fuseless Load Feeders" 400 6/18 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 If type 2 coordination fulfilled, semiconductor fuses must be fitted in the motor feeder. 1) Rated current I ...

Page 25

... Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW30 for standard applications 6/19 ...

Page 26

... The types of coordination are explained in more detail in Catalog LV 1, "Load Feeders, Motor Starters and Soft Starters" ––> "Fuseless Load Feeders". The type of coordination "2" refers only to soft starters, not to any components in the feeder. 6/20 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 F1 Q21 F3 Q11 ...

Page 27

... The soft starter dimensions should be checked where necessary with the Win-Soft Starter software or with the help of Technical Assistance. © Siemens AG 2008 4000 5000 ), n motor Roller conveyor Compressor Small fan Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW30 for standard applications Pump Hydraulic pump 6/21 ...

Page 28

... ON 13/ Win-Soft Starter selection and simulation program With this software, you can simulate and select all Siemens soft starters, taking into account various parameters such as mains properties, motor and load data, and special application requirements. The software is a valuable tool, which makes complicated, lengthy manual calculations for determining the required soft starters superfluous ...

Page 29

... Wide temperature range from -25 to +60 °C • Built-in auxiliary contacts ensure user-friendly control and possible further processing within the system graphs see page 6/36) Siemens SIRIUS Soft Starters · 01/2008 3RW40 for standard applications can be set from R (for status ...

Page 30

... IN Motor protection shut-down (overload thermistor) Thermistor defective (open-circuit, short-circuit) Thermal overloading of the thyristors Missing mains voltage, phase failure, missing load Device fault 6/24 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW40 2. Terminal A1/ 110 ... 230 ±20 ...

Page 31

... LEDs Off LEDs Yellow LEDs Green Yes Start command Off command ON Ramp-down end RUN Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications OVERLOAD Off Off Off Off Off Off Off Off Not relevant Red flashing ...

Page 32

... The quoted switching frequencies do not apply for automatic mode. 4) Maximum adjustable rated motor current I , dependent on CLASS setting. M 6/26 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW40 2.-. .B.4, 3RW40 2.-. .B.5, 3RW40 3.-. .B.4, 3RW40 3.-. .B.5, 3RW40 4.-. .B.4 3RW40 4.-. .B 200 ...

Page 33

... A 134 162 1/h 7 1.4 A 134 152 1 134 152 1/h 1.2 1.7 A 124 142 1 124 142 1 °C, stand-alone u Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications 3RW40 38 3RW40 46 3RW40 106 62 125 144 192 72 80 106 106 ...

Page 34

... Degree of protection Busbar connections Main conductors • With cable lug according to DIN 46234 or max wide - stranded - finely stranded • AWG cables, solid or stranded 6/28 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 3RW40 2. 3RW40 (1.5 ... 2.5 (1.5 ... 16 (2.5 ... 6) according to IEC 60947; ...

Page 35

... AWG 2 x (24 ... 14) for 3RW40 2. ... 3RW40 4 (24 ... 16) for 3RW40 5. and 3RW40 7. Siemens SIRIUS Soft Starters · 01/2008 3RW40 for standard applications 3RW40 7. 3RT19 66-4G 70 ... 240 70 ... 240 95 ... 300 Min 0.8 Max 0.5 3/0 ... 600 kcmil 120 ... 185 120 ... 185 120 ...

Page 36

... The radio interference suppression filter is used to remove the conducted interference from the main circuit. The field-related emissions comply with degree of noise suppression B. 6/30 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Standard Parameters ±4 kV contact discharge, ±8 kV air discharge EN 61000-4-2 EN 61000-4-3 Frequency range: 80 ...

Page 37

... Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications 575 V +10 % Rated current max Type ...

Page 38

... The types of coordination are explained in more detail in Catalog LV 1, "Load Feeders, Motor Starters and Soft Starters" ––> "Fuseless Load Feeders". The type of coordination "2" refers only to soft starters, not to any components in the feeder. 6/32 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Line contactors Size (optional) Q21 ...

Page 39

... Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications Semiconductor fuses, minimum Size Rated Size current F3 Type A -- 3NE4 101 ...

Page 40

... Class 15 Permissible installation height 105 100 1000 2000 3000 Mounting height installation height above 2000 m, the max. permissible operational voltage is reduced to 460 V. 6/34 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Motor protection tripping characteristics for 3RW40 (with asymmetry 0,1 ...

Page 41

... The soft starter dimensions should be checked where necessary with the Win-Soft Starter software or with the help of Technical Assistance. © Siemens AG 2008 ), n motor Roller conveyor Compressor Small fan Centrifuge Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters 3RW40 for standard applications Pump Hydraulic pump 6/35 ...

Page 42

... Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Status graphs Win-Soft Starter selection and simulation program With this software, you can simulate and select all Siemens soft starters, taking into account various parameters such as mains properties, motor and load data, and special application requirements. ...

Page 43

... Top Bottom Fixing screws 3RW30 03-2. (spring-loaded terminals) 3,1 1) 7,2 22,5 Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters Project planning aids 6 6 117.2 5 6.5 35 115 125 5 6.5 35 115 150 5 6.5 30 ...

Page 44

... Distances to grounded parts (mm) Lateral 3RW40 2. 5 3RW40 3. 30 3RW40 4. 30 Type/Dimension (mm 180 120 37 17 3RW40 5. 3RW40 7. 210 160 48 25 6/38 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 d e NSB0_01891a 149 126 14 149 126 14 165 140 183 158 22 ...

Page 45

... Siemens AG 2008 Automatic mode N(L-) L1(L+) 1) ON/OFF Q11 >5 min OFF t Control of a main contactor Q21 N(L-) L1(L+) 1) ON/ OFF Q11 2) 3RV motor starter protectors 3RV Q11 3RW30 M 3~ Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters Project planning aids 6/39 ...

Page 46

... T11/T21 ϑ ϑ 1) Caution: Risk of restarting When operating with a switch (ON/OFF) a new, automatic restart will take place automatically if the start command is still active at terminal 1. 6/40 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 Control by remote reset N(L 100 % >5 min ...

Page 47

... F1 3NA/3NE Q21 3RT Q11 3RW40 OVERLOAD FAILURE OVERLOAD FAILURE Siemens SIRIUS Soft Starters · 01/2008 3RW Soft Starters Project planning aids 3) 3RV/3VL motor starter protectors 3RV/3VL Q11 3RW40 M 3~ 6/41 ...

Page 48

... Soft Starters Notes 6/42 Siemens SIRIUS Soft Starters · 01/2008 © Siemens AG 2008 7 ...

Page 49

... DELTA Switches and Socket Outlets GAMMA Building Controls Human Machine Interface Systems SIMATIC HMI PDF: These catalogs are only available as pdf files. Further information can be obtained from our branch offices listed in the appendix or at www.siemens.com/automation/partner Catalog Industrial Communication for Automation and Drives CA 01 Low-Voltage Controls and Distribution – ...

Page 50

... Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. ...

Related keywords