No. Of Digits / Alpha
5
Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Approval Bodies
CE, CRUus
Display
Backlit LCD Display
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
■ Characteristics
12
Display range
Measurement accuracy
Measurement range
Input signals
Connectable sensors
Comparative output response
time (transistor output)
Linear output response time
Insulation resistance
Dielectric strength
Noise immunity
Vibration resistance
Shock resistance
Weight
Degree of
protection
Memory protection
Applicable standards
EMC
(at 23±5 C)
Timer Interval Indicator
Front panel Conforms to NEMA 4X for indoor use (equivalent to IP66)
Rear case
Terminals
±0.08% rgd ±1 digit (for voltage pulse/open collector sensors)
Functions F1, F3, and F4:10 ms to 3,200 s
Function F2:
Functions F5 and F6:
• No-voltage contact (30 Hz max. with ON/OFF pulse width of 15 ms min.)
ON residual voltage: 3 V max.
OFF leakage current: 1.5 mA max.
Load current:
2 ms max. (time until the comparative output is made when there is a forced sudden change in the input signal
from 15% to 95% or 95% to 15%)
10 ms max. (time until the final analog output value is reached when there is a forced sudden change in the
input signal from 15% to 95% or 95% to 15%)
20 M min. (at 500 VDC)
2,300 VAC for 1 min between external terminals and case
100 to 240 VAC models:
24 VAC/VDC models:
Frequency: 10 to 55 Hz; Acceleration: 50 m/s
150 m/s
Approx. 300 g (Base Unit only)
IP20
IP00 + finger protection (VDE0106/100)
EEPROM (non-volatile memory)
Number of rewrites: 100,000
UL61010C-1, CSA C22.2 No. 1010.1 (evaluated by UL)
EN61010-1 (IEC61010-1): Pollution degree 2/Overvoltage category II
EN61326: 1997, A1: 1998, A2: 2001
EMI: EN61326+A1 industrial applications
Electromagnetic radiation interference
Terminal interference voltage
EMS: EN61326+A1 industrial applications
Electrostatic Discharge Immunity
Radiated Electromagnetic Field Immunity
Electrical Fast Transient/Burst Immunity
Surge Immunity
Conducted Disturbance Immunity
Power Frequency Magnetic Immunity
Voltage Dips and Interruptions Immunity
19,999 to 99,999
F1 to F4 0 to 50 kHz
F5, F6
F1 to F4 0 to 50 kHz
F5, F6
(waveform with 1-ns rising edge and pulse width of 1 s/100 ns)
(waveform with 1-ns rising edge and pulse width of 1 s/100 ns)
CISPR 11 Group 1, Class A: CISPRL16-1/-2
CISPR 11 Group 1, Class A: CISPRL16-1/-2
EN61000-4-2: 4 kV (contact), 8 kV (in air)
EN61000-4-3: 10 V/m 1 kHz sine wave amplitude modulation (80 MHz to 1 GHz, 1.4GHz to 2 GHz)
EN61000-4-4: 2 kV (power line), 1 kV (I/O signal line)
EN61000-4-5: 1 kV with line (power line), 2 kV with ground (power line)
EN61000-4-6: 3 V (0.15 to 80 MHz)
EN61000-4-8: 30 A/m (50 Hz) continuous time
EN61000-4-11: 0.5 cycle, 0 /180 100% (rated voltage)
Mode
Mode
1,500 V at power supply terminals in normal or common mode
1,500 V at power supply terminals in normal or common mode
K3HB-P
2
(100 m/s
0 to 30 kHz
Input frequency
Input frequency
0 to 30 kHz
range
range
2
for relay outputs) 3 times each in 3 axes, 6 directions
Must be able to properly switch load currents of 5 mA or less.
Must have a switching capacity of 20 mA or higher.
20 ms to 3,200 s
0 to 4 gigacounts
9 s min.
16 s min.
9 s min.
16 s min.
pulse width
pulse width
ON/OFF
ON/OFF
4.5 to 30 V
2
, 10 sweeps of 5 min each in X, Y, and Z directions
ON voltage
Note: The Digital Time Interval Meter
will malfunction if a pulse greater
than the input frequency range is
input. SYSERR may appear on
the display.
OFF voltage
30 to 2 V
10 k
impedance
Input
•Voltage pulse
•Open collector

Related parts for K3HBPPB 100/240VAC