K3HBPPB 100/240VAC Omron, K3HBPPB 100/240VAC Datasheet - Page 29

METER, PERIOD, V/NV/PNP, 100/240AC

K3HBPPB 100/240VAC

Manufacturer Part Number
K3HBPPB 100/240VAC
Description
METER, PERIOD, V/NV/PNP, 100/240AC
Manufacturer
Omron
Datasheet

Specifications of K3HBPPB 100/240VAC

No. Of Digits / Alpha
5
Power Consumption
18VA
Svhc
No SVHC (15-Dec-2010)
External Depth
95mm
External Length / Height
48mm
Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Approval Bodies
CE, CRUus
Display
Backlit LCD Display
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Outputs
Standard, zone, and level comparative output patterns can be
selected for comparative outputs.
Prevents comparative outputs from chattering when the
measurement value fluctuates slightly near the set value.
Holds the output status when a comparative result output other than
PASS turns ON.
Comparative results other than PASS and error signals can be
output from the PASS output terminal.
Delays turning OFF comparatives for a set period. This can be used
to provide sufficient time to read the comparative output ON status
when the comparative result changes at short intervals.
Turns ON the comparative output for a specific time.
Reverses the output logic of comparative results.
Measurements can be stopped for a set time using an external input.
Output operation can be checked without using actual input signals
by using the keys to set a test measurement value.
A current or voltage proportional to the change in the measurement
value can be output.
The comparison outputs can be kept OFF until the measurement
value enters the PASS range.
Comparative Output Pattern
Hysteresis
Output Refresh Stop
PASS Output Change
Output OFF Delay
Shot Output
Output Logic
Startup Compensation Timer
Output Test
Linear Outputs
Standby Sequence
out-p
hys
o-stp
pass
off-d
shot
out-n
s-tmr
test
lset.c, lset.v, lset.h, lset.l
stdby
R P C
R
R P
R P C
R P C
R P C
R P
R P C
R P C
R
R P
Display
The display value can be set to the present value, the maximum
value, or the minimum value.
The present value display color can be set to green or red. The color
of the present value can also be switched according to the
comparative output.
When the input changes rapidly, the display refresh period can be
lengthened to control flickering and make the display easier to read.
The present measurement value can be displayed as a position in
relation to the scaling width on a 20-gradation position meter.
The input signal can be converted and displayed as any value.
Select whether or not to display the comparative value during
operation.
Automatically returns the display to RUN level when there are no key
operations (e.g., max./min. switching, bank settings using keys).
Other
Holds the maximum and minimum measurement values.
Switch between 8 comparative value banks using the keys on the
front panel or external inputs. A set of set comparative values can be
selected as a group.
Any bank settings can be copied to all banks.
The measured value can be recorded when the power supply is
interrupted.
The K3HB can be calibrated by the user.
Display Value Selection
Display Color Selection
Display Refresh Period
Position Meter
Prescale
Comparative Set Value Display
Display auto-return
Max./Min. Hold
Bank Selection
Bank Copy
Interruption Memory
User Calibration
Digital Indicators
K3HB-R/-P/-C
disp
color
d.ref
pos-t, pos-h, pos-l
ps.ax, ps.ay, ps.bx, ps.by
sv.dsp
ret
bnk-c
copy
memo
R P C
R P C
R P
R P C
R P C
R P C
R P C
C
R P C
R P C
R P C
R P C
29

Related parts for K3HBPPB 100/240VAC