RELAY CARD-INT SOLA HEVI DUTY, RELAY CARD-INT Datasheet

no-image

RELAY CARD-INT

Manufacturer Part Number
RELAY CARD-INT
Description
Intellislot Relay Card
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of RELAY CARD-INT

Features
Provides Dry Contact Relay Outputs For Custom Wired Applications And Delivers Support For Built-in Shutdown For AS/400 Systems
Accessory Type
Relay Card
For Use With
S4K5U
Lead Free Status / RoHS Status
na
P
A
OWER
VAILABILITY
S4K5U6000-5
U
M
SER
ANUAL
On-Line UPS
230VAC
Para español, consulte www.solaheviduty.com/products/ups/UPSmanuals.htm.
Die deutsche Fassung finden Sie auf www.solaheviduty.com/products/ups/UPSmanuals.htm.

Related parts for RELAY CARD-INT

RELAY CARD-INT Summary of contents

Page 1

S4K5U6000-5 Para español, consulte www.solaheviduty.com/products/ups/UPSmanuals.htm. Die deutsche Fassung finden Sie auf www.solaheviduty.com/products/ups/UPSmanuals.htm OWER VAILABILITY U M SER ANUAL On-Line UPS 230VAC ...

Page 2

...

Page 3

MPORTANT AFETY NSTRUCTIONS W S ICHTIGE ICHERHEITSANWEISUNGEN ...

Page 4

Fault Indicator LED (Red ...

Page 5

Figure 1 S4K5U, front view ...

Page 6

Table 1 Electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

Page 7

... Terre) type. (IEC 364-ELECTRICAL INSTALLATION OF BUILDINGS) ELECTROMAGNETIC COMPATIBILITY—This UPS complies with the requirements of the EMC Directive 89/336/EEC and the published technical standards. Continued compliance requires installa- tion in accordance with these instructions and the use of manufacturer approved accessories only. WARNING ! This is a product for restricted sales distribution to informed partners. Installation restrictions or additional measures may be needed to prevent radio interference. Operate the UPS in an indoor environment only in an ambient temperature range of 0-40° ...

Page 8

W ICHTIGE SICHERHEITSANWEISUNGEN DIESE ANWEISUNGEN AUFBEWAHREN Dieses Handbuch enthält wichtige Sicherheitsanweisungen. Lesen Sie alle Sicherheits- und Betriebs- anweisungen, bevor Sie die unterbrechungsfreie Stromversorgung (USV) in Betrieb nehmen. Beachten Sie alle Warnungen am Gerät und in diesem Handbuch. Befolgen Sie alle ...

Page 9

LOSSARY F YMBOLS Risk of electrical shock Gefahr eines Stromschlags Indicates caution followed by important instructions ! Zeigt einen Vorsichtshinweis an, auf den wichtige Anweisungen folgen AC input Wechselstromeingang AC output Wechselstromausgang i Requests the user to ...

Page 10

I NTRODUCTION Congratulations on your choice of the Sola/Hevi-DutyS4K5U6000-5 Uninterruptible Power System (UPS). It provides conditioned power to microcomputers and other sensitive electronic equipment. Upon generation, AC power is clean and stable. However, during transmission and distribution it may ...

Page 11

S D YSTEM ESCRIPTION Input L1 TVSS & EMI/RFI Filters N G 2.1 Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters These UPS components provide surge protection and filter both electromagnetic interference (EMI) and radio frequency interference (RFI). They ...

Page 12

DC-to-DC Converter The converter utilizes energy from the battery system and raises the DC voltage to the opti- mum operating voltage for the inverter. This allows the inverter to operate continuously at its opti- mum efficiency ...

Page 13

M C AJOR OMPONENTS The S4K5U is composed of three major assemblies to provide easier handling, installation, and versa- tility. 3.1 Main Frame and Electronics This 5U cabinet is shipped with internal batteries installed and a bypass hardwire distribution ...

Page 14

... The UPS has two internal battery packs behind a battery access door on the front of the unit. Each pack is fitted with a connector to link to the UPS. Figure 3 Internal battery pack with connector Fans REPO Connector Relay Card Slot Serial Card Slot (SNMP WEB CARD or MULTIPORT4CARD) Input Circuit Breaker 8 ...

Page 15

Removable Power Distribution Box The UPS arrives with a bypass hardwire power distribution pack installed. This box always contains the UPS input circuit breaker. Optional versions may be available to replace the standard box for custom installations. Power distribution ...

Page 16

W ’ I HAT S NCLUDED The S4K5U are shipped with the following items: • S4K5U6000-5 user manual • Vertical display overlay • MultiLink software CD • MultiLink serial cable (3m) • Rack mount handles • Support ...

Page 17

I NSTALLATION AND Do NOT attempt to start the UPS, turn on any circuit breaker or energize the input power until instructed 6.0 - Initial Start-Up and Electrical Checks. Visually inspect the UPS for freight ...

Page 18

Installing the Adjustable Rack-Mount Kit—Sold Separately This kit contains parts needed to mount several different models of UPS and external battery cabi- nets into EIA310-D standard four-post racks that are 18-32" deep (457-813mm). The weight limit per pair of ...

Page 19

Get eight (8) M4 screws and eight (8) M4 nuts from the hardware pack in this kit. Each nut has a locking, nylon insert that begins gripping the screw when it is halfway tight. Make sure to tighten the ...

Page 20

External Battery Cabinet Installation Optional Sola/Hevi-Duty external battery cabinets may be connected to the UPS to provide additional battery run time. External battery cabinets are designed to be placed on one side of the UPS or stacked beneath the ...

Page 21

Connect the Internal Batteries Using the External Connector The internal connectors of the internal battery packs will be connected when shipped. However, the internal batteries will be disconnected from the UPS using a rear panel connector. The connector attaches ...

Page 22

Figure 6 Distribution box electrical connections diagram S4KPAD-CEHW Mains Input Input 32A CB External 30 Branch CB UPS - PFC, Battery, Inverter S4KPAD-CEHW and S4KPAD-CEHW-MBS Terminal Block Connections Conduit entry holes are provided on the rear and side of the ...

Page 23

NITIAL TART P AND 1. Verify that the Input Output circuit breakers are off. 2. During initial system checks, disconnect all loads (open load disconnects). 3. Inspect all wiring, cables, and connection external battery ...

Page 24

C P ONFIGURATION ROGRAM The final step of installation may require custom configuration of your UPS using the enclosed config- uration program. Some configuration settings may be changed only while the UPS is off. These should be set before ...

Page 25

C I ONTROLS AND NDICATORS 8.1 ON/Alarm Silence/Manual Battery Test Button This button controls output power to connected load(s) and has three functions: • ON • Alarm Silence • Manual Battery Test ON - Pressing this button will start ...

Page 26

Load Level Indicators (4 Green, 1 Amber) The load level indicators display the approximate electrical load placed upon the UPS at all times. 8.4 Battery Level Indicators (5 Green) The battery level indicators display approximate battery capacity at all ...

Page 27

O I PERATING NSTRUCTIONS 9.1 Normal Mode Operation During normal operation, mains power provides energy to the UPS. The filters, power factor correction circuit and the inverter process this power to provide computer grade power to connected loads. The ...

Page 28

C OMMUNICATIONS 10.1 Communications Interface Port The S4K5U UPS has a standard DB-9 serial port female connector located on the rear of the UPS unit. Several signals are provided on this port and are assigned as follows: Table 2 ...

Page 29

... The Intellislot MULTIPORT4CARD allows you to install MultiLink software on four computers and coordinate shutdown in the event of a power failure. The Intellislot RELAY CARD-INT provides dry contact relay outputs for custom wired applications and delivers support for built-in shutdown for AS/400 systems. CAUTION ...

Page 30

Remote Emergency Power Off The UPS is equipped with a Remote Emergency Power Off (REPO) connector. The user must supply a means of interfacing with the REPO circuit to allow disconnecting the UPS input feeder breaker to remove all ...

Page 31

M AINTENANCE 11.1 Internal Battery The S4K5U requires very little maintenance. The batteries are valve-regulated, non-spillable, flame retardant, lead acid, and should be kept charged to obtain their designed life. The UPS continuously charges the batteries when connected to ...

Page 32

Internal Battery Replacement CAUTION ! A battery can present a risk of electrical shock and high short circuit current. Observe the following precautions before replacing the batteries: • Remove rings, watches and other metal objects. • Use a Phillips ...

Page 33

Remove the 5U bezel panel on the front of the UPS by removing the screws located on the sides of the bezel (see illustration at right). 2. Remove battery access door by loosening the captive screws and tipping the ...

Page 34

AC Power Connections Power connections may be disconnected from the UPS cabinet via a removable distribution box. This may be a convenient feature if the UPS must be moved a short distance or replaced. This box allows power connections ...

Page 35

T ROUBLESHOOTING The information below indicates various symptoms a user may encounter in the event the S4K5U develops a problem. Use this information to determine whether external factors caused the problem and how to remedy the situation ...

Page 36

Table 4 Troubleshooting guide Cause Problem UPS fails to start when the UPS is short-circuited or ON button is pressed. overloaded. UPS not plugged in. UPS input protection fuse Battery indicator LED is has blown/opened. illuminated. Mains voltage out of ...

Page 37

Table 4 Troubleshooting guide (cont’d) Cause Problem Fault and LEDs D&E are Charger malfunction Illuminated Battery source is not Battery LED is flashing. available; continuous horn. Table 5 Alarm conditions Condition Battery Mode (mains failure) Low Battery Output Overload (Bypass) ...

Page 38

Table 6 Battery run times Load% 10% 20% 30% 40% 50% Internal Battery (minutes) 60% 70% 80% 90% 100% 10% 20% 30% 40% Internal Battery 50 External Battery 60% Cabinet (minutes) 70% 80% 90% 100% 10% 20% 30% ...

Page 39

Auto-Learning Battery Run Times As batteries age, the estimated runtimes may become less accurate. The S4K5U is programmed to “learn” from a full battery discharge and modify the estimated runtime for the measured battery capacity. This can improve accuracy ...

Page 40

S (S PECIFICATIONS Table 7 UPS specifications Model Number Model Rating Dimensions mm (in.) Unit Shipping Weight kg (lbs) Input AC Parameters Nominal Operating Frequency Factory Default VAC User ...

Page 41

Table 8 Power distribution specifications Model Number Amps Rating Input Power Connection Output Power Connection Includes: Two IEC320 C19 16A/250V sockets Input Branch Circuit Breaker Table 9 External battery cabinet specifications Model Number Used w/ UPS model Dimensions ...

Page 42

Tabelle 10 Technische Daten zur USV Modellnummer Betriebsspannungsbereich ohne Batteriebetrieb Maximal zulässiger V AC-Wert Eingangsfrequenz ohne Batteriebetrieb Eingangsleistungsanschluss Ausgangs-Wechselstromparameter Standardeinstellung ab Werk Ausgangsanschlüsse Frequenz Wellenform Hauptmodusüberlast Batterieparameter Typ Anzahl x V Batteriehersteller /Teilenr. Sicherungszeit Wiederaufladezeit (interne Batterien) Bypass-Schutzgrenzen ...

Page 43

Tabelle 12 Technische Daten zum externen Batteriegehäuse Modellnummer Verwendet mit USV-Modell Abmessungen (in.) Gerät (mit Blende) Versand Gewicht kg (lbs) Gerät Versand Batterieparameter Typ Anzahl x V Batteriehersteller /Teilenr. Sicherungszeit Umgebung Betriebstemperatur Lagertemperatur Relative ...

Page 44

Specifications (Sechnische Daten) 38 ...

Page 45

...

Page 46

S4K5U6000-5 T ECHNICAL U.S.A………………………………(800) 377-4384 International………….……………(847) 268-6000 While every precaution has been taken to ensure accuracy and completeness in this manual, Sola/Hevi-Duty assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any ...

Related keywords