209-2-1-62-4-9-60 AIRPAX, 209-2-1-62-4-9-60 Datasheet - Page 15

CIRCUIT BREAKER, HYD-MAG, 2P, 240V, 60A

209-2-1-62-4-9-60

Manufacturer Part Number
209-2-1-62-4-9-60
Description
CIRCUIT BREAKER, HYD-MAG, 2P, 240V, 60A
Manufacturer
AIRPAX
Series
209r
Datasheet

Specifications of 209-2-1-62-4-9-60

Input Voltage Vac
240V
No. Of Poles
2
Current Rating
60A
Interrupting Capacity
5kA
Trip Time
18s
Voltage Rating Vdc
0V
Trip Time Max
18sec
Trip Time Min
2sec
Mounting Type
Panel
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
http://airpax.sensata.com/
*219 also applicable for CSA approval only.
Volts (Volts)
Voltage (V)
65
125
125/250
120
120/240
120/240
240
240
239 Circuit Breakers (Marine)
Voltage (V) Frequency (Hz) Min. Poles UL/CSA
125
279 Circuit Breakers for use in Communications Equipment
Voltage (V)
160
Volts (Volts)
Voltage (V)
125
125
125/250
300
125/250
125/250
250
277
277/480
277/480
347/600
347/600
480
600
125/250
229D Supplementary Protectors (Ignition Protected)
Voltage (V) Frequency
65
250
229G Supplementary Protectors (Generator Use – UL489 Field wired)
Voltage (V) Frequency
277/480
347/600
239 Supplementary Protectors (Marine)
Voltage (V) Frequency
250
125/250
240
240/415
Notes: (1) With 225A maximum series fuse
209 SERIES AgENCY APPROVALS
229 SUPPLEMENTARY PROTECTORS* AgENCY APPROVALS
Frequency
(Hz)
DC
DC
DC
DC
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
400
(Hz)
DC
50/60
(Hz)
50/60
50/60
(Hz)
50/60
50/60
50/60
50/60
Frequency (Hz) Min. Poles UL/CSA
DC
DC
DC
50/60
50/60
50/60
50/60
400
DC
Frequency (Hz) Min. Poles UL/CSA
DC
UG
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
A, D
UG
A, D
A, D
UG
A, D
A, D
UG
A, D
A, D
-
-
1
1
2
1 only
2
2 only
1
1
1
1
FW
0
0, 3
0, 3
0, 3
0
0
0, 3
0, 3
0
0, 3
0
0, 3
0
0
0, 3
FW
0, 3
0, 3
FW
0, 3
0, 3
FW
0, 3
0, 3
-
-
Rated Current (Amps)
.10-100
.10-125
.10-20
.10-50
.10-100
.10-50
.10-100
.10-100
.10-100
.10-100
Phase
-
-
-
-
1
1
1
1
1 & 3
1 & 3
1 & 3
1 & 3
3
3
1
Phase
-
1
Phase
3
3
Phase
1 & 3
1
1 & 3
3
Min.
Poles
1
1
2
2
2
2
1
1
2
2
2
2
3
3
2
Min.
Poles
1
1
Min.
Poles
3
3
Min.
Poles
1
2
1
3
VDE
-
.10-100
-
-
-
-
.10-100
-
VDE
-
VDE
-
TC
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
TC
1
1
TC
1
1
TC
1
1
-
-
OL
0
0
1
0
1
0
0
1
1
0
0
0
0
0
0
OL
1, (0,
CSA )
1, (0,
CSA)
OL
1
1
OL
1
1
-
-
Interrupting Capacity (Amps)
UL 489 & CSA
25000
10000
5000
10000
5000
10000
5000
2500
UL489 & CSA
5000
UL489A
5000
Rated Current (Amps)
UL/CSA
.10-100
.10-120
.10-20
.10-100
.10-115
.10-100
.10-100
.10-100
.10-100
.10-100
.10-100
.10-100
.10-100
.10-77
.10-100
UL/CSA
.10-100
.10-100
UL/CSA
.10-100
.10-77
UL/CSA
.10-100
.10-100
-
-
VDE
.10-100
.10-100
-
-
-
-
-
-
-
-
-
-
-
-
-
VDE
-
-
VDE
-
-
VDE
-
-
.10-100
.10-100
VDE
-
4000
-
-
-
-
4000
-
VDE
-
VDE
-
Interrupting Capacity (Amps)
UL 1077 & CSA No. 235
U2, 10000 / U1, 5000
U2, 5000 / U1, 5000
U1, 5000
U1, 5000
U2, 5000
U1, 10000
U1, 5000
U1, 5000
C2, 10000(1) / C1, 10000
U2, 5000 / U1, 5000
C1, 10000(1)
U1, 5000
C2, 10000(1) / C1, 10000
C2, 10000(1) / C1, 10000
U2, 1500 / U1, 2000
UL1500 & CSA
U2, 1000/U1,1000
U2, 1000/U1, 1000
UL1077 & CSA
U2, 2500
U2, 2000
UL1077 & CSA
U1, 5000
U1, 5000
-
-
209/219/229/249/279 Series - Agency Approvals
Volts (Volts)
Voltage (V)
125
120/240
120/240
240
240/415
277
277/480
277/480
480
600
250
Notes: (1) With 225 A maximum series fuse
219 MANUAL MOTOR CONTROLLERS AgENCY APPROVALS
VDE
4000
4000
-
-
-
-
-
-
-
-
-
-
-
-
-
VDE
-
VDE
-
-
VDE
-
-
4000
4000
Frequency (Hz) Min. Poles UL
DC
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
50/60
400
General notes
All supplementary protectors are of the overcurrent (OC) type
The family of protectors has been evaluated for end use application for use group
(UG) A and D
The terminals (FW) – Terminals are coded as follows:
0 – Suitable for factory wiring only
1 – Line terminals evaluated for field wiring
2 – Load terminals evaluated for field wiring
3 – Line and Load terminals evaluated for field wiring
The maximum voltage ratings for which the protectors have been tested are
shown in the chart
The current is the amperage range that the protectors have been tested
The tripping current (TC) – Tripping Current is coded as a percentage of the
ampere rating:
0 – Tripping current is less than 125% of ampere rating
1 – Tripping current is in the range of 125% to 135% of ampere rating
2 – Tripping current is more than 135% of ampere rating
3 – Tripping current is 135% and meets MCCB trip time requirements
The overload rating (OL) - Designates whether the protector or family of
protectors has been tested for general use or motor starting applications.
0 – tested at 1.5 times amp rating for general use
1 – tested at 6 times AC rating or 10 times DC rating for motor starting
The short circuit current rating (SC) – The short circuit rating in amperes
following a letter and number designating the test conditions and any calibration
following the short circuit test is defined below:
C – Indicates short circuit test was conducted with series overcurrent protection
U – Indicates short circuit test was conducted without series overcurrent
1 – Indicates a recalibration was not conducted as part of the short circuit
2 – Indicates a recalibration was performed as part of the short circuit testing
3 – Indicates recalibration was performed along with the dielectric and voltage
testing
withstand for “Suitable for Further Use” rating
protection
1
2
2
1
2
1
2
2
2
2
1
Rated Current (Amps)
.10-100
.10-100
.10-100
.10-100
-
.10-100
.10-100
.10-100
.10-100
.10-77
.10-100
VDE
.10-100
-
-
.10-100
.10-100
-
-
-
-
-
-
Interrupting Capacity (Amps)
UL 508
5000
5000
10000
5000
-
5000
5000
10000(1)
10000(1)
10000(1)
5000
VDE
4000
-
-
4000
4000
-
-
-
-
-
-
178

Related parts for 209-2-1-62-4-9-60