60198 SQUARE D, 60198 Datasheet - Page 33

MINIATURE CIRCUIT BREAKER 240V 30A

60198

Manufacturer Part Number
60198
Description
MINIATURE CIRCUIT BREAKER 240V 30A
Manufacturer
SQUARE D
Series
Multi 9r
Datasheet

Specifications of 60198

Rohs Compliant
YES
Actuator Style
Toggle
No. Of Poles
3
Current Rating
30A
Voltage Rating Vac
240V
Mounting Type
DIN Rail
© 2002–2010 Schneider Electric
All Rights Reserved
UL 1053 Listed GFP Ground Fault Protectors
The GFP Ground Fault Protector provides ground fault protection for electrical circuits. It will
automatically open the circuit in the case of a ground fault between phase and ground greater than 10,
30 or 300 mA, depending on the model. An electromechanical release operates without any auxiliary
source of supply to open the circuit. The GFP is available in 2-pole and 4-pole (3 or 4-wire) versions.
NOTE: The GFP has only one protective function—detection of ground fault current. There is no
thermal or magnetic overcurrent protection. Therefore, the circuit must be protected upstream by an
approved device such as the Multi 9 C60, QOU, QO, or HGL circuit breaker, or a fuse.
Multi 9 GFP products contain Si technology to increase immunity to noise and to minimize the potential
for nuisance tripping in noisy electrical environments.
The toggle on the front of the GFP is used to reset the device after it has tripped. It should not be used
to switch loads. A test button located on the front of the GFP is provided to allow periodic testing of the
device. The tripped condition due to ground fault is displayed on the front face by a red mechanical
indicator.
Remote monitoring and control can be provided with optional C60 accessories including the OF
Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release and/or MX + OF Shunt Trip.
NOTE: These auxiliaries require the use of the OFS Auxiliary Switch (Cat. No. 26923) to adapt to the
ID Residual Current Switch.
Table 31:
Standards
Voltage Rating
Current Rating (40°C)
Ground Fault Sensitivity:
Short-Circuit Current Rating
Frequency
Mounting
Connection, Box Lug
Padlocking in the “Tripped”
Position is Possible
Ground-Fault Indication
Temperature
Tropicalization
See Table 29 for dimensions and weights
UL 1053 (not CSA certified)
IEC 61008
CE Marked
Specifications for UL 1053 Listed GFP Ground Fault Protectors
Two Poles at 120 or 240 Vac (-15/+10%)
Two Poles at 277 or 480Y/277 Vac (-15/+10%)
Four Poles at 240 Vac or 480Y/277 Vac (-15/+10%)
25 A, 40 A, 63 A, 80 A or 100 A
GFP30
GFP100
GFP300
10 kA with Recommended Circuit Breaker or
Fuse Upstream
50 or 60 Hz.
35 mm DIN rail
Wire: 75°C copper wire only, stranded or solid
14 to 2 AWG (2.5 to 35 mm
Use a Padlocking Device
Red Indicator Flag on Front Face
Operating Temperature
Storage Temperature
Treatment 2
Section 4—Ground-Fault Protection Devices
2
)
Depending on Catalog Number
Must Trip at 29.9 mA; Must Not Trip Below 22.1 mA
Must Trip at 98.9 mA; Must Not Trip Below 73.1 mA
Must Trip at 299 mA; Must Not Trip Below 221 mA
See bulletin GHA1080850AB
Torque to 31 lb-in (3.5 N•m)
Requires Addition of OFS on Left Side of Circuit
Breaker plus Padlocking Attachment M9PAFL
-25 to +60°C (-13 to +140°F)
Relative humidity 95% at 55°C (131°F)
-40 to +70°C (-40 to + 158°F)
Multi 9™ System Catalog
07/2010
33