EGB3100FFG EATON CUTLER HAMMER, EGB3100FFG Datasheet - Page 188

CIRCUIT BREAKER, THERMAL MAG, 3P, 100A

EGB3100FFG

Manufacturer Part Number
EGB3100FFG
Description
CIRCUIT BREAKER, THERMAL MAG, 3P, 100A
Manufacturer
EATON CUTLER HAMMER
Series
Gr
Datasheet

Specifications of EGB3100FFG

Actuator Style
Toggle
No. Of Poles
3
Current Rating
100A
Voltage Rating Vdc
250V
Voltage Rating Vac
480V
Mounting Type
DIN Rail
Terminals
Screw
12-188
12
Special Low Magnetic Protection Application MCP
Table 12-308. 600 Vac Maximum, 250 Vdc Maximum
Note: HMCP 25 – 100 A come with line and load steel body terminals,
3T100FB.
MCPs for Application with Motor Starters Equipped
with Electronic Overload Relays
Table 12-309. 600 Vac Maximum, 250 Vdc Maximum
Cont.
Amps
100
NEMA
Starter
Size
0
0
25
50
70
For dc applications, actual trip levels are approximately 40% higher
than values shown.
Series C Molded Case Circuit Breakers
Motor Circuit Protectors
Low Magnetic Protection — F-Frame
Cont.
Amps
3
7
Cam
Setting
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Cam
Setting
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
MCP
Trip
Setting
103
109
115
120
115
122
130
139
145
153
160
170
160
174
185
196
207
218
229
240
Motor
Full Load
Current
Amperes
(FLA)
1.1 – 1.2
1.3 – 1.5
1.6 – 1.7
1.8 – 1.9
2.0 – 2.2
2.3 – 2.5
1.5 – 2.0
2.1 – 2.5
2.6 – 3.1
3.2 – 3.6
3.7 – 3.9
4.3 – 4.7
4.8 – 5.2
5.3 – 5.7
40
43
46
49
52
55
58
60
80
87
93
98
.69 –
.92 – 1.0
.91
MCP
Catalog
Number
HMCP025D0C
HMCP050G2C
HMCP070J2C
HMCP100L3C
MCP
Trip
Setting
12
15
18
21
24
27
30
21
28
35
42
49
56
63
70
9
MCP
Catalog
Number
HMCPS003A0C
HMCPS007C0C
For more information visit: www.eaton.com
Price
U.S. $
Price
U.S. $
Table 12-309. 600 Vac Maximum, 250 Vdc Maximum (Continued)
Note: HMCPS 3 – 100 A come with line and load steel body
terminals, 3T100FB. HMCPS 150 A come with line and load steel
body terminals, 3T150FB.
NEMA
Starter
Size
0
1
2
3
4
4
Motor FLA ranges are typical. The corresponding trip setting is at
13 x the minimum FLA value shown. Where a 13 x setting is required
for an intermediate FLA value, alternate cam settings and/or MCP
ratings should be used.
For dc applications, actual trip levels are approximately 40% higher
than values shown.
Settings above 130 amperes are for special applications. NEC Article
430-110(a) requires the ampere rating of the disconnecting means to
be not less than 115% of the motor full load ampere rating.
Cont.
Amps
15
30
50
100
150
150
Cam
Setting
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
A
B
C
D
E
F
G
H
Motor Full
Load Current
Amperes
(FLA)
103.8 – 115.2
115.3 – 126.7
115.0 – 130.7
Discount Symbol. . . . . . . . . . . . . . . . . . . . . . . . . CB-2
10.4 – 11.4
11.5 – 12.6
11.5 – 13.7
13.8 – 16.0
16.1 – 18.3
18.4 – 20.6
20.7 – 22.9
23.0 – 25.2
11.5 – 15.2
15.3 – 19.1
19.2 – 22.9
23.0 – 26.8
26.9 – 30.6
30.7 – 34.5
34.6 – 38.3
38.4 – 42.1
23.0 – 30.6
30.7 – 38.3
38.4 – 46.0
46.1 – 53.7
53.8 – 61.4
61.5 – 69.1
69.2 – 76.8
76.9 – 84.5
34.6 – 46.0
46.1 – 57.5
57.6 – 69.1
69.2 – 80.6
80.7 – 92.2
92.3 – 103.7
57.0 – 75.0
76.0 – 95.0
96.0 – 114.0
3.4 –
4.6 –
5.7 –
6.9 –
8.0 –
9.2 – 10.3
6.9 –
9.2 – 11.4
4.5
5.6
6.8
7.9
9.1
9.1
MCP
Trip
Setting
1000
1050
1200
1350
1500
1000
1250
1500
1750
2000
2250
2500
105
120
135
150
120
150
180
210
240
270
300
150
200
250
300
350
400
450
500
300
400
500
600
700
800
900
450
600
750
900
750
45
60
75
90
90
MCP
Catalog
Number
HMCPS015E0C
HMCPS030H1C
HMCPS050K2C
HMCPS100R3C
HMCPS150T4C
HMCPS150U4C
November 2008
CA08101001E
Price
U.S. $