C200H-CN711 Omron, C200H-CN711 Datasheet

no-image

C200H-CN711

Manufacturer Part Number
C200H-CN711
Description
C200H I/O CABLE, .7M
Manufacturer
Omron
Datasheet

Specifications of C200H-CN711

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
I/O Connecting Cable
I/O Modules
Special I/O Modules
CS1 CPU Bus Modules
Expansion Rack
I/O Modules
Special I/O Modules
CS1 CPU Bus Modules
CPU Rack
Serial Communications
Board
Remote I/O Master Unit
Power
Supply
Unit
CPU Backplane
Memory Card
I/O Backplane
Power
Supply
Unit
CPU Rack
A CPU Rack consists of a CPU, Power Supply Unit, CPU
Backplane, Basic I/O Modules, Special I/O Modules, and
CPU Bus Modules. The Serial Communications Board and
Memory Cards are optional.
Note:
Expansion Racks
Both C200H and CS1 Expansion Racks can be used.
• C200H Expansion I/O Racks can be connected to CPU
• CS1 Expansion Racks can be connected to CPU Racks or
An Expansion Rack consists of a Power Supply Module, a
CS1 or C200H Expansion I/O Backplane , Basic I/O Mod-
ules, Special I/O Modules, and a CS1 CPU Bus Modules.
Long-distance Expansion Racks
An I/O Control Module and I/O Interface Modules can be
used to extend the normal limit of 12 m to 50 m for each of
two series of CS1 Expansion Racks. The following Mod-
ules can be mounted to Long-distance Expansion Racks:
CS1 Basic I/O Modules, CS1 Special I/O Modules, and
CS1 CPU Bus Modules. (C200H Modules cannot be
mounted to Long-distance Expansion Racks.)
System Power and Expansion
Racks, CS1 Expansion Racks, or other C200H Expansion
I/O Racks.
other CS1 Expansion Racks.
Programmable Controller
The Backplane depends on the type of CPU Rack, Ex-
pansion I/O Racks, and Slave Racks that are used.
CS1
C--149

Related parts for C200H-CN711

C200H-CN711 Summary of contents

Page 1

... CS1 Expansion Racks can be connected to CPU Racks or other CS1 Expansion Racks. An Expansion Rack consists of a Power Supply Module, a CS1 or C200H Expansion I/O Backplane , Basic I/O Mod- ules, Special I/O Modules, and a CS1 CPU Bus Modules. Long-distance Expansion Racks An I/O Control Module and I/O Interface Modules can be used to extend the normal limit for each of two series of CS1 Expansion Racks ...

Page 2

... Flash memory (See note.) Flash memory (See note.) Flash memory (See note.) Memory Card adapter (This table continues on the next page.) CS1 These Backplanes are for CS1 Mod- ules only. Use CS1W-BCjj3 Back- planes for C200H Modules. planes for C200H Modules ...

Page 3

... Connects the CQM1-PRO01-E Programming Console. (Length: 0.05 m) Connects the C200H-PRO27-E Programming Console. (Length: 2.0 m) Connects the C200H-PRO27-E Programming Console. (Length: 6.0 m) Windows-based Support Software for Windows 95/98/Me or Windows pp NT/2000/XP NT/2000/XP Note: Can connect through peripheral port or through RS-232C port Note: Can connect through peripheral port or through RS 232C port on CPU Module or Serial Communications Board ...

Page 4

... CS1 Expansion Rack p CS1 Expansion I/O Backplane Power Supply Module For connection to a CPU Backplane or CS1 Expansion I/O Back- plane: CS1 I/O Connecting Cable For connection to a C200H Expansion I/O Backplane: CS1 to C200H I/O Connecting Cable C200H Expansion I C200H Expansion I/O Backplane ...

Page 5

... CS1W-CN221 CS1W-CN321 CS1W-CN521 CS1W-CN131 CS1W-CN131-B2 C200H-CN311 C200H I/O Connecting / g Cables C bl C200H-CN711 C200H-CN221 C200H-CN521 C200H-CN131 J Expansion Rack Patterns The following diagrams show the 5 possible patterns of Expansion Racks. CPU Rack with CS1 Expansion Racks CPU Rack CS1 I/O Connecting CS1 Expansion Rack ...

Page 6

... CS1 Expansion Rack 50 m Long-distance Connecting Cable I/O Interface Module CS1 Expansion Rack Long-distance Connecting Cable I/O Interface Module CS1 Expansion Rack Terminating Resistor CPU Rack with C200H Expansion I/O Racks CS1 to C200H I/O C200H Expansion I/O Connecting Rack Cable C200H I ...

Page 7

... I/O Interface Module CS1 Expansion Rack Long-distance Connecting Cable I/O Interface Module CS1 Expansion Rack Terminating Resistor Note: C200H Modules cannot be mounted to Long-distance Expansion Racks. (They can be mounted to the CS1 Expansion Rack with the I/O Control Module mounted.) Programmable Controller CPU Rack ...

Page 8

... CIO 0000 to CIO 9999. The first word setting can be changed only with a Programming Device other than a Programming Console. 2. The Module number setting on the front of C200H Group-2 High-density I/O Modules is ignored. Words are allocated to these Modules based on their location in the Rack. ...

Page 9

... Basic I/O Modules can be mounted to the CPU Rack, CS1 Expansion Racks, and C200HX/HG/HE Expansion I/O Racks. Note: CS1 Basic I/O Modules cannot be mounted to C200HX/ HG/HE Expansion I/O Racks. Allocation Methods 1. CPU Rack Basic I/O Modules on the CPU Rack are allocated words left to right ...

Page 10

System Power and Expansion I/O Allocations 3. CS1 Long-distance Expansion Racks Words are allocated to series A and then series B. Other- wise, allocations are the same as for other Racks. I/O Control Module Series Series B A I/O Interface ...

Page 11

... Special I/O Modules can be mounted to the CPU Rack, CS1 Expansion Racks, and C200H Expansion I/O Racks*. Note: *CS1 Special I/O Modules cannot be mounted to C200H Expansion I/O Racks. Each Module is allocated 10 words in the Special I/O Mod- ule Area, as shown in the following table. ...

Page 12

... Condition 2: Maximum Total Current Supply A × 5 VDC + B × 26 VDC + C × 24 VDC ≤ Max. Power shown in table 1. J Example Calculations Example 1 In this example, the following Modules are mounted to a CPU Rack with a C200HW-PA204S Power Supply Module. Module Model CPU Backplane CS1W-BC083 ...

Page 13

... CS1 Expansion Backplanes (for CS1 Modules only) CS1 Expansion Backplanes (for CS1 Modules only) CS1 Expansion Backplanes CS1 Expansion Backplanes I/O Interface Module C200H Expansion I/O Backplanes C200H Expansion I/O Backplanes Note: Add 0.15 A per port when the NT-AL001-E is connected. Basic I/O Modules Category Name ...

Page 14

... Triac Output Modules CS1 Output Modules CS1 Output Modules Relay Output Modules Relay Output Modules Transistor Output Modules Transistor Output Modules Triac Output Modules C200H Group 2 High density C200H Group-2 High-density Transistor Output Modules Transistor Output Modules Output Modules C--162 Programmable Controller ...

Page 15

... Name CS1 I/O Modules CS1 I/O Modules DC Input/Transistor Output DC Input/Transistor Output Modules CS1 I/O Modules CS1 I/O Modules C200H I/O Modules C200H I/O Modules B7A Interface Modules B7A Interface Modules Analog Timer Module Special I/O Modules Category Name DC Input Module C200H ...

Page 16

... System Power and Expansion Current Consumption Special I/O Modules (continued) Category Name C200H Special C200H Special ID Sensor Modules ID Sensor Modules I/O Modules I Fuzzy Logic Module Voice Module PC Card Module DeviceNet Master Module DeviceNet I/O Link Module Profibus-DP Master Module Profibus I/O Link Module ...

Page 17

... Transistor Output Modules Transistor Output Modules CS1 Output Modules CS1 Output Modules Relay Output Modules Relay Output Modules Analog Intput Module C200H Special I/O Modules C200H Special I/O Modules Analog Output Modules Analog Output Modules Analog I/O Module ID Sensor Modules ID Sensor Modules ...

Page 18

... Check that correct operation is possible in cases where changes in input specifications may influence operation. The internal 5-V current consumption increases from 120 mA to 150 mA (C200H-ID219) and from 100 mA to 150 mA (C200H-ID217). Check that the increased current is within the range of the power supply. 16-point Sinking Transistor Output Modules ...

Page 19

... V, ON response time increases from 0 0.5 ms, OFF response time increases from 0 ms.) The internal 5-V current consumption increases (from 180 mA to 270 mA). Check that the increased current is within the range of the power supply. System Power and Expansion Replacing C200H I/O Modules Corresponding CS1 I/O Module CS1W-OD212 Corresponding CS1 I/O Module CS1W-OD231 ...

Page 20

... System Power and Expansion Replacing C200H I/O Modules 64-point Sinking Transistor Output Modules Item C200H I/O Module Model number C200H-OD219 Description 64-point Transistor Output (sinking) Modules with connectors. The connectors and the pin arrangement are the same. The output current capacity increases (from 100 mA to 0.3 A per point, 1 ...

Page 21

... Notes The terminal arrangement must be changed. The ON/OFF response time changes (C200H-OC225 only). Check that correct operation is possible in cases where an increased ON/OFF response time may influence operation. (Increases from ms) The internal 5-V current consumption increases (from the range 130 and from the range ...

Related keywords