K2CU-F40A-C AC16-40AAC100 Omron, K2CU-F40A-C AC16-40AAC100 Datasheet

no-image

K2CU-F40A-C AC16-40AAC100

Manufacturer Part Number
K2CU-F40A-C AC16-40AAC100
Description
HEATER FAULT DETECTOR
Manufacturer
Omron
Series
K2CUr
Datasheets

Specifications of K2CU-F40A-C AC16-40AAC100

Current Rating
16 ~ 40 A
Mounting Type
Panel
Operational Type
Large, Built in Transformer
Voltage - Supply
100 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Gate Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
K2CU-F40A-CAC16-40AAC100
K2CUF40ACAC1640AAC100
Accurate Detection of Heater Element
Burnout Regardless of Heater Capacities
• Accurately detects a burned heater element or elements incor-
• Precisely singles out the burned element even if one heater el-
• Applicable to small- to large-capacity heater elements.
• All K2CU-F large-capacity, built-in current transformer models
• Voltage fluctuation compensation function eliminates false
Model Number Structure
■ Model Number Legend
1. Heater Element Burnout Detector
2. Operation
3. Operating Current Range
Ordering Information
K2CU-F@@A-@GS Model with Gate Input Terminals
Note: A model with a gate input terminal is required to combine the K2CU with a temperature controller that uses PID control for temperature control of a heater. To do
K2CU-@@@-@@
100 VAC
110 VAC
200 VAC
220 VAC
porated by a molding machine or packing machine and outputs
an alarm signal.
ement among several heater elements has been burned out.
work with both single-phase and three-phase heaters.
alarms due to variations in the supply voltage.
Heater Element Burnout Detector
K2CU
F:
P:
0.5: 0.25 to 0.5 A
1:
2:
4:
10: 4 to 10 A
20: 8 to 20 A
40: 16 to 40 A
80: 32 to 80 A
1
so, use a temperature controller with a voltage output.
Large-capacity, built-in Current Transformer model
Small-capacity plug-in model
0.5 to 1 A
1 to 2 A
2 to 4 A
2 3 4
With voltage fluctuation compensation
Control supply voltage
http://www.ia.omron.com/
5 6
K2CU-F10A-CGS
K2CU-F10A-DGS
K2CU-F10A-EGS
K2CU-F10A-FGS
4 to 10 A
K2CU-F20A-CGS
K2CU-F20A-DGS
K2CU-F20A-EGS
K2CU-F20A-FGS
4. Voltage Compensation
5. Control Power Supply Voltage
6. Gate Input
None:
A:
A:
B:
C:
D:
E:
F:
None:
GS:
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
8 to 20 A
100/200 VAC
110/220 VAC
100 VAC
110 VAC
200 VAC
220 VAC
Not provided
Provided
Not provided
Provided
Operating current
K2CU-F40A-CGS
K2CU-F40A-DGS
K2CU-F40A-EGS
K2CU-F40A-FGS
16 to 40 A
K2CU-F80A-CGS
K2CU-F80A-DGS
K2CU-F80A-EGS
K2CU-F80A-FGS
32 to 80 A
1

Related parts for K2CU-F40A-C AC16-40AAC100

K2CU-F40A-C AC16-40AAC100 Summary of contents

Page 1

... With voltage fluctuation compensation 110 VAC 200 VAC 220 VAC Note: A model with a gate input terminal is required to combine the K2CU with a temperature controller that uses PID control for temperature control of a heater so, use a temperature controller with a voltage output. http://www.ia.omron.com/ 4. Voltage Compensation ...

Page 2

... Operating: –10°C to 55°C (with no icing) Ambient humidity Operating: 45% to 85% Weight K2CU-F: approx. 390 g; K2CU-P: approx. 300 g Note: The logical value is an operating value within a range of 0.85 to 1.1 with a voltage fluctuation of 85% to 110%, based on the value at the control supply voltage measured as 1. http://www.ia.omron.com/ ...

Page 3

... Heater elements Approximately 3 VDC Approximately 6 VDC 3. When using a K2CU which has the model number suffix "GS" (a model that incorporates gate input terminals), the control output of the temperature controller must be a voltage output type. http://www.ia.omron.com/ The signal generated by the reference voltage generator is sent to the setting circuit to provide a reference value ...

Page 4

... When power is supplied to the heater (when the contactor is ON), a current flows through the wires to the heater elements. At the same time, a voltage is imposed on the power circuit of the K2CU-F. The current flowing to the heater wires is detected by the detector sections through each Current Transformer (CT) incorporated by the K2CU-F ...

Page 5

... Note: Values in this table are correct when a 200 VAC heater is used on a single-phase or three-phase current. http://www.ia.omron.com/ The knobs of the K2CU-F and K2CU-P as shown in the illustrations are set and 0.7 A respectively. The set operating current is defined as the mean value of the heater current under normal operating conditions and the heater current under a burnout or abnormal condition ...

Page 6

... Confirm that Close the SW indicator remains off. Turn off SW and confirm that the alarm indicator comes on, and that 1 the output relay operates (c)Copyright OMRON Corporation 2008 All Rights Reserved. K2CU with switch SW turned on. Confirm that the alarm SSR K2CU Heater 6 ...

Page 7

... K2CU Heater K2CU-F, K2CU-P The operation of the heater burnout detector can be easily checked as follows Single-phase Circuit Set the operating current to be 0.55 to 0.6 times the heater current. Close the contactor with switch SW turned on. Confirm that the 1 alarm indicator remains off. Turn off SW ...

Page 8

... K2CU-P Contactor SW 1 Heater (c)Copyright OMRON Corporation 2008 All Rights Reserved. K2CU turned on. Confirm that the 1 Contactor K2CU Heater turned on. Confirm that the 1 K2CU-F Contactor K2CU K2CU-F Heater 8 ...

Page 9

... K2CU-P Switch CM1 1 1 Note: Determine the value of R according to the specifications K2CU-F of the K2CU to be used. The dotted line indicates the connection at a supply voltage of 100 or 110 VAC. Eight, M3.5 6 terminal screws Potentiometer knob Alarm indicator 60 95 108 6-dia. mounting hole 3 ...

Page 10

... Note: 1. The dotted lines which pass through the heater burnout detector indicate the line conductor passing through the round “window” of the window-type Current Transformer External relay for self-holding circuit BZ: Alarm buzzer L: Alarm indicator 3. To use a 100 (110) VAC control power supply with K2CU-P, connect it to terminal 7 instead of 6. http://www.ia.omron.com/ Three-phase Heater Y/a L ...

Page 11

... Note: 1. The dotted lines which pass through the heater burnout detector indicate the line conductor passing through the round “window” of the window-type Current Transformer External relay for self-holding circuit BZ: Alarm buzzer L: Alarm indicator 3. To use a 100 (110) VAC control power supply with K2CU-P, connect it to terminal 7 instead of 6. http://www.ia.omron.com/ With External Current Transformer Power supply ...

Page 12

... K2CU-P The K2CU-P can be used only in single-phase circuits. Do not pull out the K2CU-P from the socket when the K2CU-P is energized. Especially when using it in combination with a Current Transformer commercially available, this practice causes the second- ary circuit of the transformer to open, which is very dangerous. ...

Page 13

... Can the K2CU be used for heaters with a voltage of 400/ Q 440? Yes ...

Page 14

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...