K2CU-F40A-C AC16-40AAC100 Omron, K2CU-F40A-C AC16-40AAC100 Datasheet - Page 3

no-image

K2CU-F40A-C AC16-40AAC100

Manufacturer Part Number
K2CU-F40A-C AC16-40AAC100
Description
HEATER FAULT DETECTOR
Manufacturer
Omron
Series
K2CUr
Datasheets

Specifications of K2CU-F40A-C AC16-40AAC100

Current Rating
16 ~ 40 A
Mounting Type
Panel
Operational Type
Large, Built in Transformer
Voltage - Supply
100 VAC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Gate Input
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
K2CU-F40A-CAC16-40AAC100
K2CUF40ACAC1640AAC100
Operation
K2CU-F@@A-@GS Series
When power is supplied to the heater (when the SSR is ON), a cur-
rent flows through the wires to the heater elements. At the same
time, a voltage is imposed on the gate circuit and the K2CU-
F@@A@GS begins monitoring the current flowing through the heater
wires.
The current flowing to the heater wires is detected by the detector
sections through each Current Transformer (CT) incorporated by the
K2CU-F@@A-@GS.
The current signals transmitted by the two CTs are sent to the cur-
rent-voltage converters, smoothing circuits, and comparators as
shown in the diagram.
Heater elements
Power supply
CT
2
SSR
CT
1
http://www.ia.omron.com/
Note: 1. The dotted lines indicate the line conductors passing through the windows of the current transformers.
G+
2. The current flowing into the gate circuit (between G+ and G−) is as follows:
3. When using a K2CU which has the model number suffix "GS" (a model that incorporates gate
Approximately 1.4 mA at 5 VDC
Approximately 3.4 mA at 12 VDC
Approximately 6.7 mA at 24 VDC
input terminals), the control output of the temperature controller must be a voltage output type.
G−
+
DC
Temperature
controller
To each circuit
Alarm indicator
Output relay
X
S
X/c
1
The signal generated by the reference voltage generator is sent to
the setting circuit to provide a reference value. The reference value is
sent to the comparators. Each comparator compares its heater ele-
ment current input and the reference value. If the input is lower than
the reference value, a signal is sent to the output circuit.
There are two detector sections operating independently. If either of
the input signals from the CTs is lower than the reference value, the
output relay and alarm indicator will be activated.
The K2CU-F@@A-@GS incorporates a voltage fluctuation compen-
sation function which automatically corrects the reference value if the
supply voltage fluctuates.
S
CM
b
a
2
1
1
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
1
Buzzer
BZ
K2CU
3