DD-9616BE-2A DENSITRON, DD-9616BE-2A Datasheet - Page 13

no-image

DD-9616BE-2A

Manufacturer Part Number
DD-9616BE-2A
Description
PMOLED, 96*16, BLUE
Manufacturer
DENSITRON
Datasheet

Specifications of DD-9616BE-2A

Resolution
96 X 16
Viewing Area (h X W)
5.504mm X 23.104mm
Pixel Size (h X W)
0.204mm X 0.204mm
Voltage Rating
2.8V
Interface
Serial
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
5 FUNCTIONAL SPECIFICATION
5.1 COMMANDS
5.2 POWER UP/DOWN SEQUENCE
To protect panel and extend the panel lifetime, the driver IC power up/down routine should
include a delay period between high voltage and low voltage power sources during turn on/off.
It gives the panel enough time to complete the action of charge and discharge before/after the
operation.
5.3 RESET CIRCUIT
Product No.
Copyright ©2009 DENSITRON TECHNOLOGIES plc. All rights reserved. – Proprietary Data
When RES# input is low, the chip is initialized with the following status:
Please refer to the Technical Manual for the SSD1306
1. Display is OFF
2. 128×64 Display Mode
3. Normal segment and display data column and row address mapping (SEG0 mapped
to column address 00h and COM0 mapped to row address 00h)
4. Shift register data clear in serial interface
5. Display start line is set at display RAM address 0
6. Column address counter is set at 0
7. Normal scan direction of the COM outputs
8. Contrast control register is set at 7Fh
9. Normal display mode (Equivalent to A4h command)
5.2.1 POWER UP SEQUENCE
5.2.2 POWER DOWN SEQUENCE
1. Power up V
2. Send Display off command
3. Initialization
4. Clear Screen
5. Power up V
6. Delay 100ms
7. Send Display on command
1. Send Display off command
2. Power down V
3. Delay 100ms
4. Power down V
(When V
(When V
completely discharges)
CC
CC
DD-9616BE-2A
DD
CC
is reach 0 and panel is
is stable)
CC
DDIO
REV. A
V
V
SS
SS
/Ground
/Ground
V
V
V
V
DD
CC
CC
DD
Display off V
V
DD
ON V
CC
CC
off V
ON Display On
Page
DD
off
13 / 24