HIRK-433A RF Solutions, HIRK-433A Datasheet
HIRK-433A
Specifications of HIRK-433A
Related parts for HIRK-433A
HIRK-433A Summary of contents
Page 1
... The outputs may be programmed for momentary or latching configuration. The modules have flash re-programmability feature to enable field re-programming of the controller. Part Numbers Part Number Superhetrodyne Receiver Decoder AM 315MHz HiRK-315A Superhetrodyne Receiver Decoder AM 433MHz HiRK-433A HiR6-433A SuperRegenerative Low Power Rx Decoder AM 433MHz HIRK-433F DS010-7 Nov 08 D ...
Page 2
... LED 22 O/P2 23 O/P3 24 O/P4 25 O/P1 Compatibility with older versions of this module ** AM-HiRK: To remain compatible with previous versions of the product, this pin may be removed and ignored. AM-HiRH : Please contact sales for part HiRK-433P534 DS010-7 Nov 08 D ECEIVER ECODER +5V Supply Voltage – RF section ...
Page 3
... RF R HiRK Application Circuit 1 3 Vcc GND Data Outputs Outputs are digital CMOS/TTL (PIC Micro) with a series 220 Ω protection resistor. Outputs are all normally low, active high. Link Positions Link1 Open Open Connected Connected Mom : This output is valid for the duration of valid key press of the transmitter switch Latch: This output changes state on each valid transmitter switch press ...
Page 4
... Active Low data Output 3 (has a 220Ω series resistor) Active Low data Output 4 (has a 220Ω series resistor) Pulled high : HiR6 operating normally. Pulled Low : HiR6 microcontroller enters sleep mode. ©2006 REG No 277 4001, England. HIRK-315 HIRK-433 H . HIR6-433 YBRID Description Page 4 ...
Page 5
... Latch/ Mom Transmitter Switch / Output Table O/P 1 O/P 2 Centre Switch LH Switch RH Switch LH Switch RH Switch ©2006 REG No 277 4001, England. HIRK-315 HIRK-433 H . HIR6-433 YBRID LED drive example O/P 1 Vcc O/P 4 O Vcc Status 1K LED Learn Sw Run / Sleep I/P Serial Data O/P ...
Page 6
... A carriage return character and a line feed character. • Please note that older versions of the HIRK used a different data format of 57.6K 7 Data Bits and 1 stop bit, these modules will be prefixed with AR4 on the end of the part number or below. These modules may still be ordered but we would highly recommend that the new HIRK modules (AR5 and above) are incorporated into new products ...
Page 7
... pressed: 2345678H (2345678h if the battery voltage in the transmitter is low) DS010-7 Nov 08 D ECEIVER ECODER A( $0A ©2006 REG No 277 4001, England. HIRK-315 HIRK-433 H . HIR6-433 YBRID 10 bytes of data transmitted Line feed (last character) Carriage return Transmitter button information with battery status Transmitter serial number Page 7 ...
Page 8
... RF R Absolute Maximum Ratings Supply Voltage (+5Vcc to GND)..........................................-0 Volts. Storage Temperature..........................................................-30 to +85 Operating Temperature....................................................... -20 to +70 Technical Specification of HiRK AM Modules o Ambient temperature = 25 Celsius. Electrical Specification Supply Voltage Supply Current Receiver Frequency Receiver Frequency Working Frequency (custom Frequencies Available) Data output voltage: (any data output) ...
Page 9
... Nov 08 D ECEIVER ECODER Min Typical 4.5 5.0 1.6 1 315.0 433.92 200 Vdd - .7 150 +/- 2 -95 Complies to ETS300-339 -25 ©2006 REG No 277 4001, England. HIRK-315 HIRK-433 H . HIR6-433 YBRID Max Dimension 5 MHz stock frequency MHz stock frequency 450 MHz Please contact Sales Dept 0 out = 8 ...
Page 10
... Information contained in this document is believed to be accurate , however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from R.F.Solutions Ltd. DS010-7 Nov 08 D ECEIVER ECODER 63.5 Component Side HiRK or HiR6 Decoder Module Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street, Lewes, E Sussex, BN8 6JL ...