CRD-5376 Cirrus Logic Inc, CRD-5376 Datasheet - Page 37

Audio Modules & Development Tools Ref Bd LP Mlt-Ch Decimation Filter

CRD-5376

Manufacturer Part Number
CRD-5376
Description
Audio Modules & Development Tools Ref Bd LP Mlt-Ch Decimation Filter
Manufacturer
Cirrus Logic Inc
Datasheet

Specifications of CRD-5376

Description/function
Audio D/A
Operating Supply Voltage
3.3 V
Product
Audio Modules
Supply Current
300 mA
For Use With/related Products
CS3301A, CS3302A, CS4373A, CS5371A, CS5372A, CS5376A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
3.3.3
The Analog Front End sub-panel configures the amplifier, modulator, and test DAC pin options. Pin op-
tions are controlled through the GPIO outputs of the digital filter.
Any changes made under this sub-panel will not be applied to the target board until the Configure button
is pushed. The Configure button writes the new configuration to the target board and then enables the
data Capture button.
3.3.4
The Test Bit Stream sub-panel configures test bit stream (TBS) generator parameters. The digitial filter
data sheet describes TBS operation and options.
The DAC Quick Set controls automatically set the Interpolation, Clock Rate, and Gain Factor controls
based on the selected Mode, Freq, and Gain. Additional configurations can be programmed by writing the
Interpolation, Clock Rate, and Gain Factor controls manually.
Any changes made under this sub-panel will not be applied to the target board until the Configure button
is pushed. The Configure button writes the new configuration to the target board and then enables the
data Capture button.
DS612RD2
Amp Mux
DAC Mode
Gain
Sw
DAC Quick Set
Interpolation
Clock Rate
Gain Factor
Sync
Loopback
Control
Control
Analog Front End
Test Bit Stream
Selects the input source for the CS3301A/02A amplifiers. An internal termination,
external INA inputs or external INB inputs can be selected.
Selects the operational mode of the CS4373A test DAC. The test DAC operational
modes are AC dual output (OUT&BUF), AC precision output (OUT only), AC buffered
output (BUF only), DC common mode output (DC Common), DC differential output
(DC Diff), or AC common mode output (AC Common). The test DAC can also be
powered down (PWDN) when not in use to save power.
Sets the amplifier gain range and test DAC attenuation. Amplifier gain and DAC
attenuation settings of 1x, 2x, 4x, 8x, 16x, 32x, or 64x can be selected and are con-
trolled together.
Selects how the DAC_BUF to INA analog switches are enabled.
Automatically sets test bit stream options. Mode selects sine or impulse output mode,
Freq selects the test signal frequency for sine mode, and Gain selects the test signal
amplitude in dB.
Manual control for the data interpolation factor of the test bit stream generator.
Manual control for the output clock and data rate of the test bit stream generator.
Manual control to set the test bit stream signal amplitude.
Enables test bit stream synchronization by the MSYNC signal.
Enables digital loopback from the test bit stream generator output to the digital filter
input.
Description
Description
CRD5376
37