ADUM4160BRWZ-RL Analog Devices Inc, ADUM4160BRWZ-RL Datasheet - Page 7

no-image

ADUM4160BRWZ-RL

Manufacturer Part Number
ADUM4160BRWZ-RL
Description
Full/Low Speed USB Digital Isolator
Manufacturer
Analog Devices Inc
Series
iCoupler®r
Datasheet

Specifications of ADUM4160BRWZ-RL

Design Resources
USB Hub Isolator Circuit (CN0158) USB Cable Isolator Circuit (CN0159) USB Peripheral Isolator Circuit (CN0160)
Inputs - Side 1/side 2
2/2
Number Of Channels
4
Isolation Rating
5000Vrms
Voltage - Supply
3.1 V ~ 5.5 V
Data Rate
12Mbps
Propagation Delay
60ns
Output Type
Logic
Package / Case
16-SOIC (0.300", 7.5mm Width)
Operating Temperature
-40°C ~ 105°C
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
105C
Package Type
SOIC W
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ADUM4160BRWZ-RL
Manufacturer:
AD
Quantity:
101
Part Number:
ADUM4160BRWZ-RL
Manufacturer:
ADI/亚德诺
Quantity:
20 000
ABSOLUTE MAXIMUM RATINGS
Ambient temperature = 25°C, unless otherwise noted.
Table 7.
Parameter
Storage Temperature (T
Ambient Operating Temperature (T
Supply Voltages (V
V
Input Voltage
Output Voltage
Average Output Current per Pin
Common-Mode Transients
1
2
3
4
All voltages are relative to their respective ground.
V
downstream sides of the coupler, respectively.
See Figure 2 for maximum rated current values for various temperatures.
Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause latch-
up or permanent damage.
DD2
DDI
(V
(V
Side 1 (I
Side 2 (I
)
, V
UD+
DD−
1
BUS1
,V
, V
, and V
UD−
DD+
O1
O2
, V
)
)
, V
SPU
DD2
SPD
, V
)
, V
1, 2
BUS2
BUS1
PIN
refer to the supply voltages on the upstream and
)
, V
1, 2
ST
BUS2
)
4
, V
DD1
3
,
A
)
Rating
−65°C to +150°C
−40°C to +105°C
−0.5 V to +6.5 V
−0.5 V to V
−0.5 V to V
−10 mA to +10 mA
−10 mA to +10 mA
−100 kV/µs to +100 kV/µs
DDI
DDO
+ 0.5 V
+ 0.5 V
Rev. B | Page 7 of 16
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
Table 8. Maximum Continuous Working Voltage
Parameter
AC Voltage, Bipolar
Waveform
AC Voltage, Unipolar
Waveform
DC Voltage
1
ESD CAUTION
Refers to continuous voltage magnitude imposed across the isolation
barrier. See the Insulation Lifetime section for more details.
Basic Insulation
Reinforced Insulation
Basic Insulation
Reinforced Insulation
Max
537
848
537
848
537
Unit
V peak
V peak
V peak
V peak
V peak
Constraint
50-year minimum
lifetime
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
Maximum approved
working voltage per
IEC 60950-1
ADuM4160