Page 1
... Mobile Phones, Netbooks, Consumer Electronics, Auto Navigation Systems, and Personal Navigation Devices. The HMC5883L utilizes Honeywell’s Anisotropic Magnetoresistive (AMR) technology that provides advantages over other magnetic sensor technologies. These anisotropic, directional sensors feature precision in-axis sensitivity and linearity. These sensors’ solid-state construction with very low cross-axis sensitivity is designed to measure both the direction and the magnitude of Earth’ ...
Page 2
... HMC5883L SPECIFICATIONS ( * Tested at 25°C except stated otherwise.) Characteristics Power Supply Supply Voltage Average Current Draw No measurement average, MA1:MA0 = 00) Performance Full scale (FS) – total applied field (Typical) Field Range Mag Dynamic Range Resolution Linearity Hysteresis Cross-Axis Sensitivity Test Conditions: Cross field = 0.5 gauss, ...
Page 3
... HMC5883L Absolute Maximum Ratings Characteristics Supply Voltage VDD Supply Voltage VDDIO PIN CONFIGURATIONS Pin Name 1 SCL 2 VDD SETP 9 GND GND 12 SETC 13 VDDIO DRDY 16 SDA Arrow indicates direction of magnetic field that generates a positive output reading in Normal Measurement configuration. www.honeywell.com (* Tested at 25°C except stated otherwise.) 2 Serial Clock – ...
Page 4
... HMC5883L PACKAGE OUTLINES PACKAGE DRAWING HMC5883L (16-PIN LPCC, dimensions in millimeters) MOUNTING CONSIDERATIONS The following is the recommend printed circuit board (PCB) footprint for the HMC5883L. 0.300 4 1.275 0.450 1.275 x 8 0.100 3.000 HMC5883 Land Pad Pattern (All dimensions are in mm) 3.000 x 12 ...
Page 5
... The HMC5883L is a fine pitch LCC package. Refer to previous figure for recommended PCB footprint for proper package centering. Size the traces between the HMC5883L and the external capacitors (C1 and C2) to handle the 1 ampere peak current pulses with low voltage drop on the traces. ...
Page 6
... HMC5883L DUAL SUPPLY REFERENCE DESIGN SINGLE SUPPLY REFERENCE DESIGN 6 www.honeywell.com ...
Page 7
... HMC5883L PERFORMANCE The following graph(s) highlight HMC5883L’s performance. Typical Resolution Typical Measurement Period in Single-Measurement Mode * Monitoring of the DRDY Interrupt pin is only required if maximum output rate is desired. www.honeywell.com 7 ...
Page 8
... Self Test To check the HMC5883L for proper operation, a self test feature in incorporated in which the sensor is internally excited with a nominal magnetic field (in either positive or negative bias configuration). This field is then measured and reported. ...
Page 9
... HMC5883L configurations. This prevents drawing down the supply voltage (VDD). MODES OF OPERATION This device has several operating modes whose primary purpose is power management and is controlled by the Mode Register. This section describes these modes. Continuous-Measurement Mode During continuous-measurement mode, the device continuously makes measurements, at user selectable rate, and places measured data in data output registers. Data can be re-read from the data output registers if necessary ...
Page 10
... HMC5883L REGISTERS This device is controlled and configured via a number of on-chip registers, which are described in this section. In the following descriptions, set implies a logic 1, and reset or clear implies a logic 0, unless stated otherwise. Register List The table below lists the registers and their access. All address locations are 8 bits. ...
Page 11
... HMC5883L Configuration Register A The configuration register is used to configure the device for setting the data output rate and measurement configuration. CRA0 through CRA7 indicate bit locations, with CRA denoting the bits that are in the configuration register. CRA7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. ...
Page 12
... HMC5883L Configuration Register B The configuration register B for setting the device gain. CRB0 through CRB7 indicate bit locations, with CRB denoting the bits that are in the configuration register. CRB7 denotes the first bit of the data stream. The number in parenthesis indicates the default value of that bit. ...
Page 13
... HMC5883L Mode Register The mode register is an 8-bit register from which data can be read or to which data can be written. This register is used to select the operating mode of the device. MR0 through MR7 indicate bit locations, with MR denoting the bits that are in the mode register ...
Page 14
... HMC5883L Data Output X Registers A and B The data output X registers are two 8-bit registers, data output register A and data output register B. These registers store the measurement result from channel X. Data output X register A contains the MSB from the measurement result, and data output X register B contains the LSB from the measurement result. The value stored in these two registers is a 16-bit value in 2’ ...
Page 15
... HMC5883L DZRA7 DZRA6 (0) (0) DZRB7 DZRB6 (0) (0) Data Output Register Operation When one or more of the output registers are read, new data cannot be placed in any of the output data registers until all six data output registers are read. This requirement also impacts DRDY and RDY, which cannot be cleared until new data is placed in all the output registers ...
Page 16
... The format of the data bytes (payload) shall be case sensitive ASCII characters or binary data to the HMC5883L slave, and binary data returned. Negative binary values will be in two’s complement form. The default (factory) HMC5883L 8-bit slave address is 0x3C for write operations, or 0x3D for read operations. ...
Page 17
... OPERATIONAL EXAMPLES The HMC5883L has a fairly quick stabilization time from no voltage to stable and ready for data retrieval. The nominal 6 milli-seconds with the factory default single measurement mode means that the six bytes of magnetic data registers (DXRA, DXRB, DZRA, DZRB, DYRA, and DYRB) are filled with a valid first measurement ...
Page 18
... C2 nominally 0.22 µF in capacitance. Low ESR characteristics may not be in many small SMT ceramic capacitors (0402 prepared to up-size the capacitors to gain Low ESR characteristics. ORDERING INFORMATION Ordering Number HMC5883L-TR Tape and Reel 4k pieces/reel FIND OUT MORE For more information on Honeywell’s Magnetic Sensors visit us online at www.honeywell.com/magneticsensors or contact us at 800-323-8295 (763-954-2474 internationally) ...