Some processes require a ramp with a gradual increase in power to
reach a new setpoint value. In addition, this ramp may require a
different gradient in order to switch from one setpoint to another. This
second value may be higher or lower than the original.
For example, a process may require a rapid heating period and a slow
cooling period.
It is for this reason that the MIC offers these two options. Two ramps
can be programmed independently - one to rise from «SP A» to a
higher setpoint value «SP B» and the second to reduce to a lower
setpoint «SP C».
Note:
This function can also be applied to switching from SP to SP2.
SP : Normal operating temperature of the process
SP2 : Temperature when idle.
Communication via the RS 485 serial link
compatible with C.BUS, MODBUS and
J.BUS protocol
For more information www.crouzet.com
This function continuously monitors current at the load.
It informs the user immediately of a break in the heating element.
MIC 48: Loads up to 100 A can be checked using an external current
transformer.
In addition, the load current can be monitored during the process.
Its value in amps can be read directly by pressing the
CTD 24: The software integrates this function without a sensor.
Two independent ramps for switching from one setpoint to another.
Heating element break monitoring function
ADDITIONAL FUNCTIONS ONLY AVAILABLE ON THE MIC 48 AND CTD 24
RPX
PLC
operator console
DIAL 5
SP / SP2 are selected by an external
switch without needing to touch the MIC
48 controller, and via the keypad on the
CTD 24.
F
key.
F
7192 / 7392 coun-
ter
threshold
checked
Current
SP B
SP C
SP A
output
output
Alarm
to be
Main
Setpoint
break monitoring
Main MIC 48
MIC 48 load
output
1st setpoint change
input
CY1
2 ramps which can be pro-
grammed independently to
switch from one setpoint to
another
O
U
T
1
2
3
Switching device
Solid state relay
2nd setpoint change
MIC 48
F
REM
°C
°F
ST
SP2
MIC 48
controller
Load break alarm
Current
transformer
Load
output
Time
Time
209
7

Related parts for 89750147