89750147 Crouzet USA, 89750147 Datasheet - Page 214

no-image

89750147

Manufacturer Part Number
89750147
Description
STAINLESS SLEEVE-MILL TEMP PRB
Manufacturer
Crouzet USA
Datasheet

Specifications of 89750147

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
7
214
General characteristics
Supply
Frequency (Hz)
Tolerance
Consumption
Display measurement
Display setpoint
Serial link
Type
Protocol
Address
Number of data bits
Transmission speed
Parity
Stop bit
Physical details and protection
Insulation resistance conforming
to IEC 348
Insulation voltage according to
IEC 348
Immunity to interference
conforming to IEC 801-4
Immunity to interference
conforming to IEC 801-2
Accuracy
Temperature limit operation (°C)
Temperature limits stored (°C)
Relative humidity (no
condensation)
Housing
Material housing
Front panel
Protection class according to IEC
529 (IEC 70-1)
Connection
Weight (g)
Approvals
UL / CSA
Protection
Safe-guard
Switch
Control characteristics
Control algorithm
Control type
Sampling time linear input
Sampling time TC and RTD input
Proportional band Pb heat or cool
Proportional band Pb heat - cool
Proportional band Pb
Note : if Pb = 0 % discrete action
Hysteresis (during discrete action) 0.1 to 10 % of scale amplitude
Integral time ti
Note : if ti > 20 min
Derivative time td.
Note : if td=0
Cycle time heating
Cycle time cooling
Heat-cool control
Cool proportional band
Heat-cool control
rC : relative gain
Heat-cool control
dead.overlap band
Digital temperature controllers MIC 48
MIC48
100 to 240 VAC, 24 VACDC
50 / 60
-15 % +10 % Un
8 VA max.
red LEDs-4 digits, 7 segment ,
height 10 mm
green LEDs-4 digits, 7 segment,
height 7.5 mm
RS485
MODBUS, J.BUS
1
8
600
even, odd, no
1
> 100 MΩ
1500 V
Level 3
8000 V
± 0.2 % of the full measurement
scale ± 1 digit at an ambient
temperature of 25
0
-20
20
self-extinguishing UL94 grade VO
Polycarbonate membrane
IP 54
screw terminals
250
in progress
detects a fault in the equipment
caused by external interference and
activates automatic reset without
modification of the process.
the configuration and calibration are
accessed via an internal switch, can
only be accessed when the device
is unplugged.
PID with auto-tune and adaptive
tune : SMART
heat or cool
heat / cool
250 ms
500 ms
1.0 to 100 % of scale amplitude
1.5 to 100 % of scale amplitude
-
20 s to 20 min
integral action is inactive
1 s to 10 min
derivative action is inactive
1 s
1 s
rC x heat proportional band
0.20
-20 % to + 50 % of the heat
proportional band
255
+50
85 % Rh
200 s
200 s
+70 °C
19 200 Bauds
1.00
o
C at Un
Characteristics
Inputs
Thermocouples J, K, R, S, and N
Thermocouples L
Reference junction
Reference junction drift
Input impedance (kΩ)
Calibration (IEC 584-1)
Resist. temp. detector 3-wire Pt
100 conforming to DIN 43760
Line resistance
Input type and standard range TC
Input types and standard
rangeRTD Pt100
Measurement range
Decimal point
Current transformer input for monitoring the load break
Input
Measurement range with
transformer
Resolution
Measurement logic threshold
Measurement update period
Setpoints
Selection input
SP/SP2
Output
Type of output
Action type
Limitation of output power : SOFT-
START- heat action
Limitation of output power : SOFT-
START-heat/cool action
Output specification
OUT 1 Main output N/O contact
OUT 1 Main output logic
Main output cycle time
OUT 2 Cool output or alarm 1
output
OUT 3 Load break output and/or
alarm 2 output
Description of alarms 1 and 2
Type of output
Functions
Reset to zero
Inhibition
Alarm threshold - absolute alarm
Alarm threshold - band alarm
Alarm threshold - deviation alarm
Alarm
IEC 584-1
DIN 43710
Automatic cold junction
compensation : 0 to 50
0.1 °C / °C
> 1 M Ω
20 Ω max. (Resistance temperature
detector)
L (0/400°C) (0/1650°F) (0/900°C)
J (0/400°C) (0/1830°F) (0/1000°C)
K (0/400°C) (0/2190°F) (0/1200°C)
N (0/1400°C) (0/2550°F)
R (0/1760°C) (0/3200°F)
S (0/1760°C) (0/3200°F)
(-199.9/400.0°C) (-199.9/400.0°F)
adjustable : - - - -, - - - . -, - - . - -, - . -
- -
50 mA AC
10 A
10 to 20 A : 0.1 A
21 to 100 A : 1 A
Relay output : NO or NC
Logic output : level 1 or 0
50 ms
- main setpoint : SP
- auxiliary setpoint : SP2
50 mA AC
selection via external N/C type
contact
discontinuous
can be programmed for heating
and/or cooling
adjustable from 0 to 100 %
adjustable from -100 to +100 %
3A 250 V AC resistive (N/C contact
is possible via a jumper)
Level 0 : <0.5 V DC
Level 1 :
14 V DC±20 % @ 20 mA max
24 V DC±20 % @ 1 mA max
1 s
N/O-2A contact, 250 V AC resistive
N/O-2A contact, 250 V AC resistive
direct or reverse
absolute alarm
band alarm
deviation alarm
Manual / automatic
Configuration
absolute value independent from
SP
value relative to SP, adjustable from
0 to 500 °C/°F
value relative to SP, adjustable
from-500 °C/°F (negative deviation)
to + 500°C/°F (positive deviation)
0.1 to 10 % of scale amplitude
(Thermocouples)
(-200/800°C) (-330/1470°F)
For more information www.crouzet.com
99 s
100 A
o
C

Related parts for 89750147