GT3F-1AD24 IDEC, GT3F-1AD24 Datasheet

no-image

GT3F-1AD24

Manufacturer Part Number
GT3F-1AD24
Description
GT3F-1AD24 8PIN DPDT TRUE POWER OFF DELAY TIMER
Manufacturer
IDEC
Datasheet
Timers
Key features of the GT3A series include:
Specifi cations
Operation
Time Range
Rated Voltage
Contact Ratings
Minimum Applicable Load
Voltage Tolerance
Error
Setting Error
Reset Time
Insulation Resistance
Dielectric Strength
Power Consumption
(approximate)
Mechanical Life
Electrical LIfe
Weight (approximate)
Vibration Resistance
Shock Resistance
Operating Temperature
Operating Humidity
Storage Temperature
Housing Color
4 selectable operation modes on each model
External start, reset, and pause inputs
Panel mount or socket mount
Large variety of timing functions
Power and output status indicating LEDs
UL, c-UL Listed
File No. E55996
(200V AC, 60Hz)
Delayed SPDT
GT3A-1
10.8VA
63g
50,000 operations minimum (rated load)
10,000,000 operations minimum
GT3A Series — Analog Timers
USA: 800-262-IDEC
30V DC, 1A (resistive load)
125V AC/250V AC, 3A;
Between power and output terminals: 2,000V AC, 1 minute
Between contacts of different poles: 2,000V AC, 1 minute
instantaneous SPDT
Between contacts of the same pole: 750V AC, 1 minute
Delayed SPDT +
(200V AC, 60Hz)
24VAC/1.2VA
24VDC/0.7W
Operating extremes: 100m/sec
Multi-mode
12VDC/1W
±0.2%, ±10 msec (repeat, voltage, temperature)
GT3A-2
Damage limits: 500m/sec
13.5VA
AD24: 20.4 to 26.4V AC/21.6 to 26.4V DC
73g
Canada: 888-317-IDEC
AF20 (100V AC): 85 to 264V AC
100m/sec
5V, 10mA (reference value)
24V AC, 50/60Hz / 24V DC
100 to 240V AC, 50/60Hz
D12: 10.8 to 13.2V DC
60msec maximum
100MW minimum
0.1s to 180 hours
±10% maximum
45 to 85% RH
–10 to +50°C
–30 to +80°C
2
12V DC
(approximate 10G)
Gray
2
(approximate 50G)
2
(approximate 10G)
(200V AC, 60Hz)
Delayed DPDT
24VAC/1.3VA
12VDC/1.1W
24VDC/0.6W
GT3A-3
14.4VA
100,000 operations minimum (rated load)
79g
5,000,000 operations minimum
30V DC, 5A (resistive load)
125V AC/250V AC, 5A;
GT3A Series
Multi-mode with inputs (11 pins)
14.4VA (200V AC, 60Hz)
4.7VA (100V AC, 60Hz),
Delayed DPDT
GT3A-4,-5,-6
24VAC/1.3VA
12VDC/0.8W
24VDC/0.6W
80g
805

Related parts for GT3F-1AD24

GT3F-1AD24 Summary of contents

Page 1

... Operating extremes: 100m/sec Damage limits: 500m/sec –10 to +50° 85% RH –30 to +80°C Gray USA: 800-262-IDEC Canada: 888-317-IDEC GT3A Series GT3A-3 GT3A-4,-5,-6 Multi-mode with inputs (11 pins) 125V AC/250V AC, 5A; 30V DC, 5A (resistive load) Delayed DPDT Delayed DPDT 14.4VA 4 ...

Page 2

... Delayed DPDT (resistive load) Time Range Output Contact Input 250V AC, 5A, Start 0.1 seconds Delayed 24V DC, 5A Reset to 180 hours DPDT (resistive load) Gate www.idec.com Timers Complete Part No. 8-Pin 11-Pin GT3A-1AF20 GT3A-1EAF20 GT3A-2AF20 GT3A-2EAF20 GT3A-2D12 GT3A-2ED12 GT3A-2AD24 GT3A-2EAD24 GT3A-3AF20 GT3A-3EAF20 GT3A-3D12 ...

Page 3

... Delayed C Contact (8p) (NO (11p) POWER Indicator OUT Cycle 3 Item Terminal Number (ON fi rst) Set Time (8p) Power (11p) MODE (8p) (NC (11p) Delayed D Contact (8p) (NO (11p) POWER Indicator OUT Timing Diagrams/Schematics (+) j POWER Operation Operation Operation Operation USA: 800-262-IDEC Canada: 888-317-IDEC GT3A Series 807 ...

Page 4

... Mode s k Selection (-) (+) j POWER Operation ON-Delay 1 T MODE A Interval 1 MODE Operation T B Cycle 1 (OFF fi rst) MODE C Operation T T Cycle 3 (ON fi rst) MODE D www.idec.com 8-Pin 11-Pin (-) (+) (-) POWER POWER Item Terminal Number Operation Set Time (8p) Power (11p (8p) (NC (11p) ...

Page 5

... Delayed Contact (NO POWER Indicator OUT Set Time T = Set time Ta = Shorter than set time T" (Transistor Input Reset Start Gate (-) (+) (-) j j POWER USA: 800-262-IDEC Canada: 888-317-IDEC GT3A Series (B Type) Start Reset (+) (-) (+) j POWER POWER Operation T' T" Operation T" T" Operation T" Operation 809 ...

Page 6

... POWER Indicator OUT Set Time T = Set time Ta = Shorter than set time T" 810 (Transistor Input Reset Start Gate (-) (+) (-) j POWER (NC) (NO (NC) (NO (NC) (NO (NC) (NO www.idec.com (B Type) Start Reset (+) (-) j j POWER POWER Operation T' T" Operation Ta T' T" T Operation Operation T T' Timers (+) T" Ta T" ...

Page 7

... POWER Indicator OUT Set Time T = Set time Ta = Shorter than set time T" (Transistor Input Reset Start Gate (-) (+) (-) j j POWER USA: 800-262-IDEC Canada: 888-317-IDEC GT3A Series (B Type) Start Reset (+) (-) (+) j POWER POWER Operation T' T" Operation T' T" Operation T' T" Operation Ta T' T" 811 ...

Page 8

... Selection www.idec.com POWER Indicator (fl ashes during time-delay period) m Setting Knob l Time Range Selector 1S, 10S, 10M, 10H Remarks The desired operation mode can be selected from the and D modes using the Operation Mode Selector. Change the operation mode from and D in turn by turning the operation mode selector clockwise using a fl ...

Page 9

... Operating extremes: 100N (approximate 10G) Damage limits: 500N (approximate 50G) –10 to +50°C –30 to +80° 85% RH 70g 75g USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series GT3D-4 GT3D-8 Multi-mode one-shot output 125V AC/250V AC, 5A; 30V DC/5A (resistive load) Delayed DPDT Delayed DPDT 3 ...

Page 10

... AC/DC Output Contact Rated Voltage Code 100 to 240V AC (50/60Hz) Delayed DPDT 24V AC/DC Output Contact Rated Voltage Code 100 to 240V AC (50/60Hz) Delayed DPDT 24V AC/DC www.idec.com Timers Complete Part No. 8-Pin 11-Pin GT3D-2AF20 GT3D-2EAF20 GT3D-2AD24 — GT3D-3AF20 GT3D-3EAF20 GT3D-3AD24 — Complete Part No. ...

Page 11

... Digital Time Digital Time Display Display UP UP Timing Diagrams/Schematics 11-Pin (+) (-) (+) j POWER Operation Operation Set Time Set Time Operation Operation Set Time Set Time Operation Operation Set Time Set Time Operation Operation Set Time Set Time USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series 815 ...

Page 12

... OUT OUT Time Elapsed DOWN DOWN Digital Time Digital Time Display Display 816 11-Pin (+) (-) (+) j POWER Operation Operation Set Time Set Time Operation Operation Set Time Set Time Operation Operation Set Time Set Time Operation Operation Set Time Set Time www.idec.com Timers ...

Page 13

... POWER Terminal Number Terminal Number (NC) (NC (NO) (NO OUT OUT DOWN DOWN Terminal Number Terminal Number (NC) (NC (NO) (NO OUT OUT DOWN DOWN USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series (Transistor Input) Start Reset Start Reset (-) (+) (-) j j POWER POWER Operation Operation Operation Operation (+) 817 ...

Page 14

... OUT OUT DOWN DOWN Terminal Number Terminal Number (NC) (NC (NO) (NO OUT OUT DOWN DOWN Terminal Number Terminal Number Start Start ( ( ( (B) Reset Reset ( ( ( (B) Gate Gate ( ( (NC) (NC (NO) (NO DOWN DOWN www.idec.com Operation Operation T T Operation Operation T T Operation Operation T’ T’ Timers ...

Page 15

... Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series Operation Operation T’ T’ Operation Operation T’ T” Operation Operation T T’ T” Operation Operation T’ T” 819 ...

Page 16

... (NC) (NC (NO) (NO DOWN DOWN Terminal Number Terminal Number Start Start ( ( ( (B) Reset Reset ( ( ( (B) Gate Gate ( ( (NC) (NC (NO) (NO DOWN DOWN www.idec.com Operation Operation Ta T’ T” T Operation Operation T’ T” T Operation Operation Ta T T’ T” Operation Operation Ta T’ T” T” Timers ...

Page 17

... UP UP Set Time Set Time GT3D-4 Timing Diagrams Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( Terminal Number Terminal Number ( ( ( ( ( ( ( ( ( ( USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series Operation Operation T T’ T” Operation Operation T’ T” Operation Operation Ta Ta T’ T” Ta 821 ...

Page 18

... Reset Gate Gate (NC) (NC (NO) (NO DOWN DOWN Terminal Number Terminal Number Start Start Reset Reset Gate Gate (NC) (NC (NO) (NO DOWN DOWN www.idec.com (Transistor Input Start Gate (-) (+) j POWER Operation Operation Tb T’ T” Operation Operation T’ T” Ta Operation Operation T’ T” Tb Timers ...

Page 19

... M 999 H 99.9 Selection USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series m Time Setting Digital Switch l Time Range Selector 9.99S – 99.9H Remarks 1. Use the fl at screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation may be necessary ...

Page 20

... S 99.9 999 99.9 M 999 H 99.9 Selection www.idec.com Timers m Time Setting Digital Switch l Time Range Selector 9.99S – 99.9H Remarks 1. Use a fl at screwdriver to set the selectors. Since selectors do not turn all the way around, both clockwise and counterclockwise rotation is necessary. 2. The j Indicator Mode Selector determines whether the Digital Time Display shows the time elapsed or time remaining ...

Page 21

... Use the m Time Setting Digital Switch to set the desired period of time important to remember that the setting of the l Time Range Selector determines the units of time measurement as well as the implied decimal point location. USA: 800-262-IDEC Canada: 888-317-IDEC GT3D Series m Time Setting Digital Switch l Time Range Selector 9.99S – ...

Page 22

... An inrush current fl ows during the minimum power application time. AF20: approximate 0.4A, AD24: approximate 1.2A 2. GT3F does not read the preset time range shown on the knob after power is turned off. Note that minimizing the preset time, by turning the knob to zero, does not shorten the delay time after power is removed. ...

Page 23

... DC, 3A (resistive load) Timing Diagrams/Schematics Delayed SPDT Output, with Reset Input Operation USA: 800-262-IDEC Canada: 888-317-IDEC GT3F Series Complete Part Number Optional Input 8-Pin 11-Pin GT3F-1AF20 GT3F-1EAF20 Reset GT3F-1AD24 GT3F-1EAD24 GT3F-2AF20 GT3F-2EAF20 None (8p) Reset (11p) GT3F-2AD24 GT3F-2EAD24 GT3F-1E (11-pin) 827 ...

Page 24

... When power is applied, the NO contact closes. When power is removed, the timing period begins. When time has elapsed, the NO contact opens. Optional reset input will return contacts to original state before time elapses Set time Ta = Shorter than set time Second Tr = Minimum Power Application Time GT3F-1: 1 Second Item Terminal Number Power Reset ...

Page 25

... Step 2 The set time is selected by turning the l Setting Knob. Instructions: Setting GT3F Series Timers Selection k Time Range Selector Time range can be selected from 1S and 10S using a fl at screwdriver and fi different dials 18, and are displayed in the six windows by turning the Dial Selector, allowing for selecting the best suited scale ...

Page 26

... Circuit Insulating Transformer On the GT3F timers, connect the input signals to terminal No.1 and 4 only on the 8-pin type; connect the input signals to terminal No. 6 and 7 only on the 11-pin type. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged. Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wir- ing. The GT3F, consisting of a high-impedance circuit, may not be reset due to the infl ...

Page 27

... Time Selector Time 0.05 sec 0.1 sec 0.25 sec 0.5 sec USA: 800-262-IDEC Canada: 888-317-IDEC GT3S Series Delta Output Indicator Star Setting Knob k Star-Delta Switching Time Selector 0.05 sec, 0.1 sec, 0.25 sec, 0.5 sec Part No. ...

Page 28

... Between contacts of the same pole: 750V AC, 1 minute Vibration Resistance 100 m/sec 2 (Approx. 10G) Operating extremes: 100m/sec Shock Resistance Damage limits: 500m/sec Type 2.3VA (100V AC, 60Hz), Power GT3S-1 4.0VA (200V AC, 60Hz) Consumption Type 2.3VA (100V AC, 60Hz), (Approx.) GT3S-2 3.8VA (200V AC, 60Hz) 832 2 (Approx. 10G) 2 (Approx. 50G) www.idec.com Timers ...

Page 29

... The star delayed contact goes on when power is turned on and goes off after a set time for the star contact (T delayed contact goes on after star-delta switching time (T The instantaneous contact goes on when power is turned on and goes off when power is turned off Star ON time (Set Time Star-delta switching time USA: 800-262-IDEC Canada: 888-317-IDEC GT3S Series Operation The delta 1 ) and goes off when power is turned off ...

Page 30

... Damage limits: 490m/sec (approx. 50G times in each of 3 axes IP40 (enclosure), IP20 (socket) (IEC60529) 2.3VA 4.6VA 1.8VA/0.9W Free 40Hx 36W 72g www.idec.com Timers Contact Ratings Allowable Contact Power 960VA/120W Allowable Voltage 250V AC/150V DC Allowable Current 5A Maximum permissible 1800 cycles per hour ...

Page 31

... Time Range Time Range Scale Selector sec - 60 sec 1M 6 sec - 6 min 10H USA: 800-262-IDEC Canada: 888-317-IDEC GT3W Series Rated Voltage Pin Confi guration New Part Numbers 8 pin GT3W-A11AF20N 100 to 240V AC (50/60Hz) 11 pin GT3W-A11EAF20N 8 pin GT3W-A11AD24N 24V AC/DC 11 pin GT3W-A11EAD24N 8 pin ...

Page 32

... Delayed (NC) OFF during T1 Contact 1-3 ON during T2 Ry1 (NO) 5-8 Delayed (NC) OFF during T1 Contact 6-8 ON during T2 Ry2 (NO) OUT1 Indicator OUT2 Set Time www.idec.com (+) Operation Chart Operation Description No. 2-7 ON during T1 OFF during T2 ON during T1 OFF during Operation Description No. 2-7 ON during T1 ON after T1, ...

Page 33

... Install the Electronic Timer according to instructions described in this catalog. • Make sure that the operating conditions are as described in the specifi ca- tions. If you are uncertain about the specifi cations, contact IDEC in advance. • In these directions, safety precautions are categorized in order of importance to Warning and Caution ...

Page 34

... GT3F-1, 2 (8-pin) SR2P-05C GT3W (8-pin) GT3S GT3A- (11-pin) GT3A- GT3D- (11-pin) SR3P-05C GT3D-4, 8 GT3F-1, 2 (11-pin) GT3W (11-pin) GT3A- (8-pin) GT3D- (8-pin) GT3F-1, 2 (8-pin) SR2P-06 GT3W (8-pin) GT3S GT3A- (11-pin) GT3A- GT3D- (11-pin) SR3P-06 GT3D-4, 8 GT3F-1, 2 (11-pin) GT3W (11-pin) — BNDN1000 Insert the springs into the slots ...

Page 35

... GT3A- (8-pin) GT3D- (8-pin) GT3W- (8-pin) SR2P-51 GT3F- (8-pin) GT3S GT3A- (11-pin) GT3D- (11-pin) SR3P-51 GT3W- (11-pin) GT3F- (11-pin) Appearance (Shown: SR6P-M08G for Wiring Socket Adapter) USA: 800-262-IDEC Canada: 888-317-IDEC GT3 Series Accessories Applicable HD Springs Appearance Part No. SFA-402 Use with Timers Part No ...

Page 36

... Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for input wiring. 840 Instructions: Wiring Inputs for GT3 Series Input Terminal 2 10 Power Input Terminal 2 10 www.idec.com Timers ...

Page 37

... The time-delay operation is suspended while the gate input Gate Input is on (pause). Inputs Instructions, continued No-voltage contact inputs and NPN open collector transis- tor inputs are applicable. 24V DC, 1mA maximum Input response time: 50msec maximum USA: 800-262-IDEC Canada: 888-317-IDEC GT3 Series Instructions 841 ...

Page 38

... Dimensions 36.0 70.0 5.6 NOTE: GT3W series are UL Listed when used in combination with following IDECʼs sockets: GT3W-A11, A33: SR2P-06* pin type socket. GT3W-A11E: SR3P-05* pin type socket. (*-May be followed by A,B The socket to be used with these timers are rated: -Conductor Temperature Rating 60º ...

Page 39

... USA: 800-262-IDEC Canada: 888-317-IDEC GT3 Series Dimensions 3.82" (98mm) Maximum Panel Thickness 0.03" to 0.2" (0.8 to 5mm) 0.066" 1.66" (1.7mm) (42.5mm) 0.12" Wiring Socket Adapter 2.39" (61.2mm) (3mm) 843 ...

Page 40

... When using solid state devices, be cautious of inrushes and back-EMF that may exceed the ratings on such devices. Some timers are specially designed so that signal inputs switch at a lower voltage than is used to power the timer (models designated as “B” type). Timing Accuracy Formulas 2 Maximum Scale Value www.idec.com Timers ...

Related keywords