Coil Voltage Vdc Nom
24V
Coil Resistance
360ohm
Contact Configuration
SPDT
Relay Terminals
Quick Connect
Terminal Type
Quick Connect
No. Of Poles
1
Contact Carrying Power
1.6W
Carry Current
60A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
54
Contact Data
Contact configuration
Circuit symbol
(see also Pin assignment)
Rated voltage
Rated current
Limiting continuous current
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended load
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load without
component in parallel to the coil)
Max switching rate at nominal load
1)
2)
3)
4)
Load Limit Curve
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 14 V for 12 V or 28 V for 24 V load voltages.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
Special high performance 24 V version with contact gap > 0.8 mm, part number V23134-A0056-X432/-X433 (see ordering information).
See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/
2)
1)
4)
NO contact
NC contact
125°C
23°C
85°C
Plug-In Relays
Mini ISO Relays
Power Relay F4 / VF4
All specifications subject to change. Consult Tyco Electronics for latest specifications.
operations
40 A, 14 V
> 2 x 10
1 Form A or 1 Form A (2 x 87)
120 A
12 V
40 A
60 A
Typ. 15 mV, 200 mV max.
1 Make contact/
5
60 A
40 A
17 A
or
operations
20 A, 28 V
> 1 x 10
120 A
24 V
20 A
20 A
5
2 x 25 A, 14 V
6 operations per minute (0.1 Hz)
operations
2 x 100 A
> 2 x 10
Typ. 2 x 15 mV, 200 mV max.
2 x 25 A
2 x 40 A
12 V
1 Double make contact/
See load limit curve
Load limit curve 1
during transit time (changeover contact)
Load limit curve 2
no stationary arc (make contact)
Silver based
5
> 10
1 Form U
2 x 32 A
2 x 25 A
2 x 11 A
1 A at 5 V
7
operations
2 x 15 A, 28 V
operations
2 x 100 A
> 1 x 10
2 x 15 A
2 x 15 A
24 V
^
= arc extinguishes
^
= safe shutdown,
5
(NO contact) (NO contact) (NO contact)
operations
40 A, 14 V
45/120 A
> 2 x 10
30/40 A
40/60 A
NC/NO
12 V
Typ. 15 mV, 200 mV max.
Typ. 20 mV, 250 mV max.
1 Changeover contact/
5
operations
20 A, 28 V
45/120 A
> 1 x 10
1 Form C
45/60 A
30/40 A
12/17 A
15/20 A
15/20 A
NC/NO
NC/NO
24 V
Catalog 1308028-2
5
(NC contact)
operations
operations
Revised 4-2009
30 A, 28 V
10 A, 28 V
> 1 x 10
> 5 x 10
45/120 A
20/30 A
20/30 A
NC/NO
24 V
3)
5
5