3G2A5-DA002 Omron, 3G2A5-DA002 Datasheet - Page 49

no-image

3G2A5-DA002

Manufacturer Part Number
3G2A5-DA002
Description
C500 2-D/A: 0 TO +10V
Manufacturer
Omron
Datasheet

Specifications of 3G2A5-DA002

Lead Free Status / Rohs Status
Lead free / RoHS Compliant
System Configurations
Where I/O Units Can be
Mounted
36
Special I/O
Units
Host Link
Units
I/O Units
Memory Packs RAM or ROM Packs are available. The ROM Pack requires a separately available EPROM chip.
Remote I/O
Master Unit
16-, 32-, 64-point I/O
Interrupt Input
Special I/O
I/O Link
PC Link
Host Link (see note 1)
SYSMAC Link
SYSMAC Net Link
File memory
Remote I/O Master
Remote I/O Slave
Unit
The number of Special I/O Units that can be used depends upon the number of points available and
the number of points the Special I/O Unit requires. Be sure to check the current capacity for each I/O
Unit and the CPU.
When using 3G2A5-LK103(-P)/LK203 Host Link Units, a maximum of two Rack-mounting Host Link
Units can be mounted to the CPU Rack or I/O Rack. An additional CPU-mounting Host Link Unit can
be mounted to the CPU, making the total number of Host Link Units three.
When using 3G2A5-LK101-(P)EV1/LK201-EV1 Host Link Units, only one Rack-mounting Host Link
Unit can be mounted to the CPU Rack or I/O Rack. An additional CPU-mounting Host Link Unit can
be mounted to the CPU, making the total number of Host Link Units two.
These Host Link Units cannot be mounted on Expansion I/O Rack.
If the SYSMAC Net Link Unit is mounted, either 3G2A5-LK103(-P) or 3G2A5-LK203 can be mounted
as Rack-mounting Host Link Unit. Both models cannot be mounted at the same time.
Standard I/O Units are available with 16, 32, or 64 points. These Units can be mounted to or removed
from the Rack if there is an I/O Remove Unit mounted to the Rack. Refer to Section 2 Description of
All Components for details.
Install identical Memory Packs in both CPUs, if you are using a C2000H Duplex PC.
Up to eight Remote I/O Master Units can be mounted to both the I/O Rack and the Expansion I/O
Racks. When the Remote I/O Unit is mounted to a Rack, a Rack number must be set so that the CPU
can identify the Remote I/O Unit. Mount the Remote I/O Slave Unit to the leftmost position (the I/O
Interface Unit position) on the Slave Rack. For details, refer to the C1000H/C2000H Operation
Manual.
Note
YES
YES (4 max.)
YES
YES
YES (2 max.)
YES
YES
YES
YES (1 max.)
YES
NO
The table below summarizes the Units that can be used in the systems de-
scribed in this manual.
The table below summarizes specific Units that can and cannot be mounted in
the CPU and Expansion Racks and the number that can be used in each PC. For
detailed information about the Units listed below, refer to the Operation Manual
for the individual Unit.
CPU Rack
1. A CPU-mounting Host Link Unit can be mounted, in addition to the Rack-
2. The Position Control Unit (3G2A5-NC103-E) and the PID Unit each require
3. The following Units can only be mounted to one of the three or five rightmost
C1000H and C2000H Simplex
mounting Host Link Unit.
two I/O slots on the CPU Rack and the Expansion I/O Racks
slots on the CPU Backplane, depending on which Backplane is used.
PC Link
Host Link
SYSMAC Net Link
File Memory
SYSMAC Link
Total: 2
max.
YES
NO
YES
YES
NO
NO
NO
NO
NO
YES
YES
Expansion I/O Rack
YES
NO
YES
YES
YES (2 max.)
YES
NO
YES
YES
YES
NO
I/O Rack
Total: 2
max.
C2000H Duplex
YES
NO
YES
YES
NO
NO
NO
NO
NO
YES
YES
Expansion I/O Rack
Section 3-5