G3RD-X02PN DC24 Omron, G3RD-X02PN DC24 Datasheet - Page 6

no-image

G3RD-X02PN DC24

Manufacturer Part Number
G3RD-X02PN DC24
Description
OUTPUT MODULE
Manufacturer
Omron
Series
G3RDr
Datasheets

Specifications of G3RD-X02PN DC24

Circuit
SPST-NO (1 Form A)
Output Type
DC
Load Current
2A
Voltage - Input
19.2 ~ 28.8VDC
Voltage - Load
3 ~ 52.8 V
Mounting Type
Through Hole
Termination Style
PC Pin
Package / Case
Module
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
On-state Resistance
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
G3RD-X02PNDC24
G3RDX02PNDC24
G3RDX02PNDC24NC
Basic Models (Drip-proof Models
*
Specifications
Ratings (Basic, Split-contact and Maintained contact Models)
Z-15 (Except Micro Load and Flexible Rod Models)
* Figures in parentheses are for the Z-15HW52, Z-15HW78(-B) and Z-15H2(-B) models, the AC ratings of
Z-15 (Flexible Rod Models)
Z-10F
Actuator
Flexible rod
(steel wire)
Contact
gap
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Contact
gap
Series
connec-
tion
Parallel
connec-
tion
these models are 125 and 250 V only.
H, H2
Drip-proof terminal protective cover
H2, E
G, H,
Rated voltage
: Solder terminal
G
E
Rated
voltage
125 VAC
250 VAC
500 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Rated
voltage
125 VAC
250 VAC
30 VDC
125 VDC
250 VDC
125 VAC
250 VAC
30 VDC
125 VDC
250 VDC
Item
*
Item
Resistive load
Resistive load
: Screw terminal
NC
NC
Resistive load
15 (10)
15 (10)
Classification
Non-inductive load (A)
Non-inductive load (A)
NC
0.25
0.75
Contact gap
0.5
0.4
0.2
0.3
0.4
0.2
10
15
15
15
15
15
15
15
15
15
15
15
6
2
2
Non-inductive load (A)
Terminal
0.6
0.6
0.3
10
10
10
1
6
6
6
NO
NO
*
*
NO
*
0.25
0.75
High-sensitivity
NC
2.5
1.5
0.5
0.4
0.2
0.3
NC
0.4
0.2
Lamp load
Lamp load
3
3
3
3
3
3
2
3
3
3
2
1
2
2
2
2.5
0.6
2.5
0.6
0.3
NC
Lamp load
4
4
1
3
4
High-sensitivity
Not provided
H (0.25 mm)
Z-15HNJS55-B
Z-15HNJS55
1.25
0.75
0.25
0.75
NO
1.5
1.5
1.5
1.5
0.5
1.5
1.5
1.4
0.4
0.2
1.5
1.5
1.5
0.3
NO
0.5
0.4
0.2
Model
1
1
1
1
1.25
NO
1.5
0.6
1.5
0.6
0.3
2
2
1
2
Inductive load
Inductive load
NC
NC
Inductive load
)
15 (10)
15 (10)
NC
0.05
0.03
0.03
0.02
0.03
0.02
0.4
0.2
15
10
15
10
15
15
10
0.05
0.05
6
5
1
7
5
7
7
1
Inductive load (A)
Inductive load (A)
0.1
0.1
Inductive load (A)
6
6
6
4
4
4
NO
NO
*
*
NO
Minimum Order Lot
The following models are available at the minimum order lot specified
below.
Orders must be placed per lot.
Actuator
Flexible rod (steel wire)
0.05
0.03
0.03
0.02
0.03
0.02
1.5
0.4
0.2
2.5
1.5
NC
NC
0.05
0.05
Motor load
Motor load
5
3
5
5
5
5
5
1
5
5
5
3
3
1
NC
0.1
0.1
Motor load
5
3
6
4
2
6
0.75
0.05
0.03
0.03
0.02
0.03
0.02
0.05
0.05
NO
2.5
1.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
2.5
0.4
0.2
NO
1.5
1.5
0.5
NO
2.5
1.5
0.1
0.1
1
2
1
3
2
1
3
Classification
Contact gap
Z-01H
Note: 1. The above current ratings are the values
Use the switch within the operating
range.
125 VAC
8 VDC
14 VDC
30 VDC
Minimum
applicable
load
Rated voltage
30
24
12
5
0
0.1
Unusable
range
2. Inductive load has a power factor of 0.4
3. Lamp load has an inrush current of 10
4. Motor load has an inrush current of 6
5. The normally closed and normally open
6. The AC ratings of molded terminals are
7. The ratings values apply under the
5 mW
0.16 mA
High-sensitivity
Z-15HNJS55-B
of the steady-state current.
min. (AC) and a time constant of 7 ms
max. (DC).
times the steady-state current.
times the steady-state current.
ratings of reverse hinge lever models are
opposite to each other.
125 and 250 V only.
following test conditions:
(1) Ambient temperature: 20±2°C
(2) Ambient humidity: 65±5%RH
(3) Operating frequency: 20 operations/min
H (0.25 mm)
1 mA
1
Micro load area
Z-01H
5 VDC 1 mA
Z-01H
Resistive load (A)
10
NC
800 mW
Minimum order
26 mA
100 mA 160 mA
Z-15@, Z-10FY
5 VDC 160 mA
0.1
0.1
0.1
0.1
lot (pcs)
100
Standard load
area
Z-15H, H2
Z-15G
Z-15E
Z-10FY
Z-15ER
10
Current (mA)
NO
1,000
Z
6

Related parts for G3RD-X02PN DC24