Specifications of H3YN-41 DC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
4PDT (4 Form C)
Delay Time
0.1 Min ~ 10 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
3A @ 250VAC
Voltage - Supply
24VDC
Mounting Type
Socket
Termination Style
Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3YN-41DC24
H3YN41DC24
Miniature Timer with Multiple Time
Ranges and Multiple Operating
Modes
Ordering Information
Connecting Socket
Hold-Down Clips
Panel Adapter
Solid-State Timer
Note:
Supply voltage
24, 100 to 120, 200 to 230 VAC;
12 2
12, 24, 48, 100 to 110, 125 VDC
24 VDC
Applicable Timer
H3YN-2/-21
H3YN-4/-41
H3YN-4-Z/-41-Z
Applicable socket
PYF08A-E, PYF08A-N, PYF14A-E, PYF14A-N
PY08, PY08QN(2), PY08-02, PY14, PY14QN(2), PY14-02
Applicable timer
H3YN-2/21. H3YN-4/41, H3YN-4-Z/41-Z
H3YN -
MODEL NUMBER LEGEND:
ACCESSORIES (ORDER SEPARATELY)
,
Minimize Inventory
Standard multiple operating modes and
multiple time ranges
4PDT or DPDT control output
LED power-ON and time-UP indicators
Sockets, hold-down clips and mounting
accessories may be ordered separately
Specify both the model number and supply voltage when ordering.
8 100
Example: H3YN-2
1
,
2
110 12 VDC
-
3
Track-mounting/front-
connecting socket
PYF08A-E, PYF08A-N
PYF14A-E, PYF14A-N
;
24 VAC
R
1. Output
2: DPDT
4: 4PDT
i
Supply voltage
Time-limit contact
DPDT
4PDT
4PDT (Twin contact)
g/
k
Back-connecting socket
Solder terminal
PY08
PY14
2. Time Range
None: Short-time range (0.1 s to 10 min)
1: Long-time range (0.1 min to 10 hrs)
1
Short-time range model
(0.1 s to 10 min)
H3YN-2
H3YN-4
H3YN-4-Z
Wire-wrap terminal
PY08QN(2)
PY14QN(2)
Part number
Y92H-3
Y92H-4
Part number
Y92F-78
3. Contact Type
None: Single contact
Z: Twin contact
Long-time range model
(0.1 min to 10 h)
H3YN-21
H3YN-41
H3YN-41-Z
PCB terminal
PY08-02
PY14-02
H3YN

Related parts for H3YN-41 DC24

H3YN-41 DC24 Summary of contents

Page 1

... PYF14A-E, PYF14A-N H3YN-4-Z/-41-Z Hold-Down Clips Applicable socket PYF08A-E, PYF08A-N, PYF14A-E, PYF14A-N PY08, PY08QN(2), PY08-02, PY14, PY14QN(2), PY14-02 Panel Adapter Applicable timer H3YN-2/21. H3YN-4/41, H3YN-4-Z/41-Z Short-time range model (0 min) H3YN-2 H3YN-4 H3YN-4-Z 2. Time Range None: Short-time range (0 min) 1: Long-time range (0.1 min to 10 hrs) ...

Page 2

... Control outputs DPDT: 4PDT: Note: 1. Single-phase, full-wave-rectified power supplies can be used. 2. When using the H3YN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated sup- ply voltages (supply 95% to 110% with 12 VDC type). CHARACTERISTICS Item Repeat accuracy ...

Page 3

... Maximum current of 0.2 A can be switched if L ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 0 VDC (P reference value). 250 VAC, cosφ = 0.4 5,000 24 VDC, L 1,000 500 200 Load current (A) 250 VAC, cosφ = 0.4 5,000 24 VDC, L 1,000 500 200 Load current (A) 3 H3YN ...

Page 4

... Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) Power (13-14) Time limit contact NC (9-1, 10-2, 11-3, 12-4) Time limit contact NO (9-5, 10-6, 11-7, 12-8) Run/Power indicator (PW) Output indicator (UP) 4 H3YN ...

Page 5

... H3YN PULSE OPERATION A pulse output for a certain period can be obtained with a random external input signal. Use the H3YN in interval mode as shown in the following timing charts. H3YN-2/-21 Timer circuit External input H3YN-4/-41 H3YN-4-Z/-41-Z Timer circuit External input Caution ! Be careful when connecting wires. ...

Page 6

... H3YN Operation DIP SWITCH SETTINGS The 1-s range and ON-delay mode for H3YN-2/-4/-4-Z, the 1-min range and ON-delay mode for H3YN-21/-41/-41-Z are factory-set before shipping. Time Ranges Model Time range Time setting range H3YN- 0 H3YN-4 H3YN-4-Z H3YN-4 min 0 min ...

Page 7

... PY08QN (PY14QN see note) H3YN H3YN 59.3 series series (7.33) 41.5 (1.63) PY08QN (PY14QN) PY08 (PY14) 7 H3YN Fourteen, 3 × 1.2 elliptic holes 28 max. (1.10) 21.5 max (0.25) (0.85) Note: Models in parentheses are sockets connecting to the H3YN-4/-4-Z. ...

Page 8

... H3YN Mounting Holes Mounting Height Two, 4.5 dia H3YN Series 90.5 86.6 (3.56) 59±0.3 (3.41) PYFjA 15±0.2 (.59) Mounting Holes Two, 4.5 dia 59±0.3 (2.32) 22±0.2 (0.87) Mounting Holes (for Surface Mounting) 3.2 dia. 19.8 3.6 dia. Mounting Holes (for Surface Mounting) Two, 3 ...

Page 9

... Hold-Down Clips The hold-down clip makes it possible to mount the H3YN securely and prevent the H3YN from falling out due to vibration or shock. Terminal Arrangement Panel Cutout (Bottom View) 25.8 PY08 PY14 Terminal Arrangement (Bottom View) ...

Page 10

... Spacer 10 PFP-S (0.39) 1.8 6.2 (0.07) (0.24) 1 35.3 35.5 (1.39) 1.8 1.3 (0.05) 4.8 (0.19) 10 H3YN Y92H-4 for PYj Socket 9R 30.5 24.5 2.5 20 (84°) 33.7 16 (0.63) 35±0 (0.04) (0.06 (0.63) 5 (0.20) 12 34.8 44.3 (1 ...

Page 11

... Use the following safety circuit when building a self-holding circuit with the H3YN and an auxiliary relay, such Relay, in combination. : H3YN MY Relay In the case of the above circuit, the H3YN will be in pulse operation. NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4. R OMRON ELECTRONICS LLC One East Commerce Drive ...

Related keywords