H3YN-41 DC24

Manufacturer Part Number
H3YN-41 DC24
Description
TIMER MINI-MULTI TIME
Manufacturer
Omron
Series
H3YNr
Datasheets

Specifications of H3YN-41 DC24

Relay Type
Integrated
Function
Programmable (Multi-Function)
Circuit
4PDT (4 Form C)
Delay Time
0.1 Min ~ 10 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
3A @ 250VAC
Voltage - Supply
24VDC
Mounting Type
Socket
Termination Style
Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3YN-41DC24
H3YN41DC24
H3YN
Specifications
Note:
Item
Time ranges
Supply voltage
Operating mode
Operating voltage
Power consumption
Control outputs
Item
Repeat accuracy
Setting error
Resetting time
Insulation resistance
Dielectric strength
Vibration
Shock
Ambient temperature
Ambient humidity
Service life
Weight
Approvals
RATINGS
CHARACTERISTICS
1. Single-phase, full-wave-rectified power supplies can be used.
2. When using the H3YN in any place where the ambient temperature is more than 50°C, supply 90% to 110% of the rated sup-
ply voltages (supply 95% to 110% with 12 VDC type).
p
Mechanical durability
Malfunction durability
Mechanical durability
Malfunction durability
Operating
Storage
Operating
Mechanical
Electrical
H3YN-2/-4/-4-Z
0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min
max. selectable)
24, 100 to 120, 200 to 230 VAC; 12, 24, 48, 100 to 110, 125 VDC (see note 1)
ON-delay, interval,repeat cycle with ON-start or OFF-start (selectable with DIP switch)
85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage)
(see note 2)
24 VAC:
100 to 120 VAC:
200 to 230 VAC:
12 VDC:
24 VDC:
48 VDC:
100 to 110 VDC:
125 VDC:
DPDT:
4PDT:
5 A at 250 VAC, resistive load (cosφ = 1)
3 A at 250 VAC, resistive load (cosφ = 1)
H3YN-2/-21
±1% FS max. (1 s range: ±1%±10 ms max.)
±10%±50 ms FS max.
Min. power-opening time: 0.1 s max. (including halfway reset)
100 MΩ min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed
non-current-carrying metal parts)
2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output)
1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
2,000 VAC, 50/60 Hz for 1 min
(between contacts of different poles)
10 to 55 Hz, 0.75-mm single amplitude
10 to 55 Hz, 0.5-mm single amplitude
1,000 m/s
100 m/s
- -10°C to 50°C (14°F to 122°F) with no icing
- -25°C to 65°C (- -13°F to 149°F) with no icing
35% to 85% RH
10,000,000 operations min. (under no load at 1,800 operations/h)
DPDT:
500,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
4PDT:
200,000 operations min. (H3YN-4-Z/-41-Z: 100,000 operations min.)
(3 A at 250 VAC, resistive load at 1,800 operations/h)
Approx. 50 g
UL/CSA/CE (EMC) (LV)
Relay ON: 1.1 VA (at 24 VAC, 60 Hz)
Relay OFF: 0.2 VA (at 24 VAC, 60 Hz)
Relay ON: 14 VA (at 120 VAC, 60 Hz)
Relay OFF: 0.6 VA (at 120 VAC, 60 Hz)
Relay ON: 1.5 VA (at 230 VAC, 60 Hz)
Relay OFF: 0.9 VA (at 230 VAC, 60, Hz)
Relay ON: 0.9 W (at 12 VDC)
Relay OFF: 0.07 W (at 12 VDC)
Relay ON: 0.9 W (at 24 VDC)
Relay OFF: 0.7 W (at 24 VDC)
Relay ON: 1.0 W (at 48 VDC)
Relay OFF: 0.2 W ( at 48 VDC)
Relay ON: 1.3 W (at 110 VDC)
Relay OFF: 0.3 W (at 110 VDC)
Relay ON: 1.3 W (at 125 VDC)
Relay OFF: 0.3 W (at 125 VDC)
2
(approx. 10G)
2
(approx. 100G)
2
H3YN-21/-41/-41-Z
0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h
max. selectable)
H3YN-4/-41
2,000 VAC, 50/60 Hz for 1 min
(between contacts of different poles)
H3YN